Payment Terms | T/T |
Supply Ability | 100-1000 |
Delivery Time | 15-20 work days |
Brand Name | Atlas Parts |
Place of Origin | China |
Model Number | 1089045110 |
View Detail Information
Explore similar products
2901086501 Atlas Oil Filter Perfect For Maintenance And Repair In Manufacturing
Atlas 1614874799 Oil Filter For Maintenance And Repair Of Other Screw Air
Atlas Host 1616753582 Screw Air Compressor By Professionals
Atlas 1625752500 Oil Filter For Screw Air Compressor Maintenance And Repair
Product Specification
Payment Terms | T/T | Supply Ability | 100-1000 |
Delivery Time | 15-20 work days | Brand Name | Atlas Parts |
Place of Origin | China | Model Number | 1089045110 |
High Light | 1089045110 VALVE SOLENOID ,Atlas Parts VALVE SOLENOID |
A solenoid valve is an electromechanically controlled valve that regulates fluid flow (liquids, gases, steam) by using an electromagnetic coil to actuate a plunger or piston mechanism. When energized, the magnetic field moves the plunger to open or close the valve orifice, providing rapid, reliable flow control in automated systems.
Feature | Benefit | Technical Impact |
---|---|---|
Millisecond Response | Near-instantaneous actuation | Enables precise process timing |
Zero Power Consumption (Latching Type) | Maintains position without continuous power | Ideal for battery-operated systems |
Compact Form Factor | 30-50% smaller than pneumatic equivalents | Saves panel/pipe rack space |
Media Versatility | Compatible with >500 fluids (including cryogenics) | Single valve for multiple services |
Explosion-Proof Options | Intrinsically safe designs available | Certified for Zone 1 hazardous areas |
Parameter | Standard Range | Specialized Options |
---|---|---|
Orifice Size | 0.5mm to 50mm | Micro-orifice (0.2mm) |
Flow Coefficient (Cv) | 0.01 to 15.0 | High-Cv (up to 25) |
Pressure Range | Vacuum to 250 bar | Ultra-high (700 bar) |
Temperature Range | -40°C to +200°C | Cryogenic (-196°C) / HT (+400°C) |
Voltage Tolerance | ±10% standard | Wide-range (9-36VDC) |
Electrical Connections | DIN43650, EN175301 | Explosion-proof conduits |
IP Rating | IP65 standard | IP69K (steam wash) |
Direct-Acting
Force equation: F = (N×I)² × μ₀ × A / (2g²)
Pros: No minimum pressure required
Cons: Limited to small orifices (<3mm)
Pilot-Operated
Uses differential pressure (ΔP ≥ 0.3 bar)
Pros: High flow capacity
Cons: Requires minimum pressure
Force-Balanced
Balanced plunger design
Pros: Stable at high ΔP
Cons: Complex manufacturing
Type | Flow Matrix | Typical Use |
---|---|---|
2-Way | 1 inlet + 1 outlet | Basic on/off |
3-Way | 1 in + 2 out (or 2 in + 1 out) | Mixing/diverting |
4-Way | 2 in + 2 out | Actuator control |
Component | Standard Material | Advanced Alternatives |
---|---|---|
Body | Brass CW617N | Titanium Gr.5 |
Core Tube | 430F Stainless | Hastelloy C276 |
Seals | NBR (Buna-N) | Kalrez® 6375 |
Plunger | 17-4PH SS | Tungsten Carbide |
Metric | Benchmark | Test Standard |
---|---|---|
Cycle Life | 50M cycles (lubricated) | IEC 60534-4 |
Leakage Class | IV (0.01% Cv) | ANSI/FCI 70-2 |
Coil Insulation | Class H (180°C) | UL 1446 |
Surge Protection | 5kV/500A (1μs) | IEC 61000-4-5 |
Oil & Gas
NACE MR0175 compliant
Double-block-and-bleed designs
Pharmaceutical
Electropolished 316L bodies
Cleanability (ASME BPE)
Mobile Hydraulics
Vibration resistant (20g)
CANbus/J1939 interfaces
Media Characterization
Conductivity >50μS/cm? → Consider low-power coils
Particulate loading >50ppm → Specify hardened trim
Dynamic Analysis
Calculate Cv using:
Q = Cv × √(ΔP/SG)
Verify water hammer potential
Failure Mode Analysis
NFPA 85 requires fail-open for burner safety valves
SIL-3 applications need redundant solenoids
Predictive Monitoring
Coil resistance (±10% baseline)
Actuation time trending
Preventive Actions
Annual diaphragm replacement
5-year coil dielectric testing
Troubleshooting
Use flux probe to verify magnetic field
Measure inrush vs. holding current
Standard | Compliance Level |
---|---|
ATEX | II 2G Ex db IIC T6 |
PED | Category IV |
FDA | 21 CFR 177.2600 |
UL | Class I Div 2 |
IoT-Enabled
WirelessHART integration
Predictive failure analytics
Digital Twins
Real-time performance simulation
Virtual commissioning
For custom engineering solutions, provide:
P&ID with valve location
Process data sheet
Failure mode requirements
Technical Note: Solenoid force decreases exponentially with air gap - critical for high-pressure designs.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Year Established:
2012
Total Annual:
10000000-50000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
Shanyan Industrial (Shanghai) Co., Ltd, & Quansi Industrial (Guanyun)Co.,Ltd a leading manufacturer and supplier of air compressor accessories.like Atlas, Gardner Denver,Ingersoll Rand,CompAir,Sullair,Fusheng, Kobelco,Unites,Bolete and so on. Our factory specializes in producing high-quali... Shanyan Industrial (Shanghai) Co., Ltd, & Quansi Industrial (Guanyun)Co.,Ltd a leading manufacturer and supplier of air compressor accessories.like Atlas, Gardner Denver,Ingersoll Rand,CompAir,Sullair,Fusheng, Kobelco,Unites,Bolete and so on. Our factory specializes in producing high-quali...
Get in touch with us
Leave a Message, we will call you back quickly!