Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 80000pcs/yearCryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump |
Delivery Time | 1-30 working days |
Packaging Details | standard export package, or as per customer request |
Heating Type | Multi-power Heat |
Performance COP (C.O.P.) | 5.0 |
Max Pool Volume (m3 / Gal) | 600 / 158400 |
Water Side Heat Exchanger | Shell & Tube |
Operating Voltage | 220-380-410V |
Application | Villa Family, Sauna and Swimming Pool, Hotels |
Brand Name | LN |
Model Number | SJKRS-05I/C |
Certification | CE ISO CCC ROHS |
Place of Origin | China |
View Detail Information
Explore similar products
CO2 R744 Air Source Water Source Heat Pump For Hot Water House Heating
65C 85C Air Source High Temp Heat Pump R134A R744 Radiator Boiler Heating
IPV4 Waterproof Grade CO2 Heat Pump Water Heater With Inverter Technology
DC Inverter CO2 R417 R744 Heat Pump High COP For Cooling And Heating
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 80000pcs/yearCryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump |
Delivery Time | 1-30 working days | Packaging Details | standard export package, or as per customer request |
Heating Type | Multi-power Heat | Performance COP (C.O.P.) | 5.0 |
Max Pool Volume (m3 / Gal) | 600 / 158400 | Water Side Heat Exchanger | Shell & Tube |
Operating Voltage | 220-380-410V | Application | Villa Family, Sauna and Swimming Pool, Hotels |
Brand Name | LN | Model Number | SJKRS-05I/C |
Certification | CE ISO CCC ROHS | Place of Origin | China |
High Light | Residential CO2 Air Source Heat Pump ,Dorin Compressor Air Source Heat Pump ,90Degree Co2 Heat Pump |
Description of R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor
The compressor sucks low-temperature and low-pressure gaseous carbon dioxide refrigerant from the evaporator, and compresses the carbon dioxide refrigerant into a high-temperature and high-pressure supercritical fluid through work. The high-temperature and high-pressure supercritical fluid enters the gas cooler to exchange heat with water, and is cooled in the gas cooler. The high-pressure fluid releases a lot of heat, and the water absorbs the heat released and the temperature continues to rise. After the high-pressure fluid is throttled and depressurized by the expansion valve, it absorbs heat from the surrounding air and evaporates into low-pressure gas through the action of the fan in the evaporator, and is sucked into the compressor to be compressed, and the cycle is repeated to produce hot water. Features Natural environmental protection refrigerant: ODP is 0, GWP is 1, no pollution to the environment, non-toxic, non-flammable Excellent high-temperature heating performance: the highest water output can reach above 90℃ Excellent low temperature performance: at -20°C ambient temperature, 90°C high temperature hot water can still be produced High efficiency: the heating performance COP can reach 4.5, and when the hot water is produced at low temperature, the COP is still above 2.0 Wide range of application: it can work normally in the ambient temperature range of -20℃~43℃, suitable for our production of domestic or industrial hot water
Performance of R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor
Ultra-low temperature working conditions: ambient temperature DB-10-C, water inlet temperature 9°C;
Defrost condition: ambient temperature DB2°C/WB1°C, water inlet temperature 9°C; low temperature condition: ambient temperature DB7°C/WB6°C, water inlet temperature 9°C; standard working condition: ambient temperature DB20°C /WB15°C, inlet water temperature 15°C; high temperature working condition: ambient temperature DB38°C/WB23°C, inlet water temperature 29°C.
Installation Notes:
1. The spacing around the installation must not be less than Im;
2. The pipelines other than the heat pump should be protected from frost and heating elements can be installed;
3. Heat insulation and protection measures should be taken for the pipelines for hot water circulation to prevent heat loss.
HP | A/mm | B/mm | C/mm |
7.5 | 1450 | 950 | 1450 |
10 | 1600 | 950 | 1500 |
15 | 1850 | 1150 | 1900 |
20 | 2050 | 1150 | 1950 |
30 | 2670 | 1410 | 2150 |
40 | 2290 | 2270 | 1980 |
Application Diagram Pressure-bearing water tank
R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor
System Diagram Smart Control System
R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor
CO2 heat pump hot water unit specification list R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor | ||||||||
Model | SJKRS-05I/C | SJKRS-28II/C | SJKRS-36II/C | SJKRS-55II/C | SJKRS-73II/C | SJKRS-106II/C | SJKRS-160II/C | |
Specification | 2HP | 7.5HP | 10HP | 15HP | 20HP | 30HP | 45HP | |
Power supply | 230V/1N/50Hz | 380V/3N/50Hz | ||||||
Heating Method | Direct heating / circulating | |||||||
Nominal working condition | ( kw)heating capacity | 7.45 | 28.1 | 37.7 | 56.1 | 74.1 | 108.6 | 158.7 |
( kw) Input power | 1.61 | 6.1 | 8.2 | 12.2 | 16.1 | 23.6 | 34.5 | |
COP | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | |
( m³/h) Heating water flow | 0.11 | 0.6 | 0.81 | 1.21 | 1.62 | 2.33 | 3.41 | |
High temperature working conditions | (kw)heating capacity | 5.58 | 23.9 | 28.5 | 51.5 | 59.5 | 89 | 131.5 |
( kw)Input power | 1.73 | 7.5 | 8.9 | 16.1 | 18.6 | 27.8 | 41.1 | |
COP | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | |
( m³/h) Heating water flow | 0.07 | 0.27 | 0.33 | 0.59 | 0.68 | 1.02 | 1.51 | |
Low temperature working conditions | (kw)heating capacity | 4.3 | 15.7 | 19.1 | 31.8 | 38.9 | 59.3 | 90 |
( kw)Input power | 1.59 | 5.8 | 7.1 | 11.8 | 14.4 | 21.9 | 33.3 | |
COP | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | |
(m³/h) Heating water flow | 0.07 | 0.28 | 0.34 | 0.56 | 0.68 | 1.04 | 1.52 | |
Parts information | Water pipe interface size | DN15 | DN20 | DN25 | DN32 | |||
Water heat exchanger | Plate or tube heat exchanger | |||||||
Air heat exchanger | Copper tube aluminum fins | |||||||
Compressor type | Double rotary | Semi-closed reciprocating type | ||||||
Operation panel | Color touch screen | |||||||
Maximum outlet temperature | 85℃ | 90℃ | ||||||
Refrigerant | R744(CO2) | |||||||
Design pressur(MPa) | 15MPa(HP)/8MPa(LP) | |||||||
Dimensions (L,W,H mm) | 750*390*1245 | 1450*950*1450 | 1600*950*1500 | 1850*1150*1900 | 2050*1150*1950 | 2670*1410*2150 | 2070x2150x2245 | |
( dB) Noise | ≤44 | ≤56 | ≤59 | ≤62 | ≤67 | ≤70 | ≤70 | |
( kg) Weight | 83 | 550 | 660 | 780 | 860 | 1180 | 1360 | |
Feedwatertemperature(℃) | 5~40 | |||||||
( Feed water pressure MPa) | 0.05~0.4 | |||||||
Water Outlet temperature (℃) | 55~85 | 55~90 | ||||||
Maximum flow | 0.24 | 1.2 | 1.5 | 2.4 | 3.2 | 4.9 | 6.5 | |
Ambient temperature (℃) | -25~43 |
System schematic diagram
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2002
Total Annual:
1.MILLION-2MILLION
Employee Number:
50~150
Ecer Certification:
Site Member
As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ... As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ...
Get in touch with us