Payment Terms | T/T |
Supply Ability | 100 Units Per Month |
Delivery Time | 8 working days |
Packaging Details | Carton box , 530 - 360 - 130mm |
Charge discharge Voltage | 0V - 5V |
Charge discharge Current | 1 , 5uA – 1mA 2 , 1mA – 5mA 3 , 5mA – 10mA |
Per Unit Main Channels No. | 8 |
Noise | less than 85dB |
Dimensions | 1U |
Working Temperature Range | 0 - 40 Degree Celsius |
Brand Name | Neware |
Model Number | CT-4008T-5V10mA-164 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
8 Channel Battery Grading System , Neware Deep Cycle Battery Analyzer
CR2025 Button Coin Battery Cell Cycler DCIR Pulse Capacity Analyzer
10mA Rechargeable Battery Capacity Tester , Neware 8CH Anode Material Analyzer
MYSQL Database Battery Cell Cycler 5V10mA Charge Discharge Test
Product Specification
Payment Terms | T/T | Supply Ability | 100 Units Per Month |
Delivery Time | 8 working days | Packaging Details | Carton box , 530 - 360 - 130mm |
Charge discharge Voltage | 0V - 5V | Charge discharge Current | 1 , 5uA – 1mA 2 , 1mA – 5mA 3 , 5mA – 10mA |
Per Unit Main Channels No. | 8 | Noise | less than 85dB |
Dimensions | 1U | Working Temperature Range | 0 - 40 Degree Celsius |
Brand Name | Neware | Model Number | CT-4008T-5V10mA-164 |
Certification | CE | Place of Origin | China |
High Light | 1U Battery Cell Cycler ,Sensitive galvanometer Battery Cell Cycler ,Sensitive galvanometer battery discharger & capacity tester |
Neware Battery Cycle Life Tester for Battery Cell Charge and Discharge Test
1 . Sensitive galvanometer is used for students to check weak current or tiny voltage in DC circuit in the lab .
2 . It is a kind of high sensitive magnetoelectric instrument , which can measure the tiny current .
3 . This 8 Channels Coin Cell Analyzer 5V10mA provides most applications in battery testing fields such as electrode materials research, battery performance test , small - scale battery formation , capability grading , battery pack testing and etc .
20 set of mA Neware battery testers can be put in one rack
4 . Testing with the uA current unit is more accurate and more convenient .
5 . The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate .
6 . The lower range is able to output current low as 5uA , which can tell the subtle difference of various materials such electrodes , electrolyte , separator , etc .
7 . Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level .
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 0V - 5V |
Discharge Min Voltage | 0V | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Power | Per Channel Output Power | 0.25W |
Stop current | Range 1 , 2uA Range 2 , 0.01mA Range 3 , 0.02mA | |
Stop current | Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA | |
Stop current | Range 1 , 2uA Range 2 , 0.05mA Range 3 , 0.1mA | |
Stability | 0.1percent of FS | |
Data Recording | Record Condition | Min Current - Range 1 , 2uA Range 2 , 0.01mA Range 3 , 0.02mA |
Min Current - Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA | ||
Min Current - Range 1 , 2uA Range 2 , 0.05mA Range 3 , 0.1mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time | ||
IP protection level | Protection level IP20 | |
A Means of Communication of Upper Machine | TCP / IP Protocol | |
Communication Interface | Ethernet Port | |
Per Unit Main Channels No. | 8 | |
Dimensions | 3U , 480 – 404 - 130mm |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
250000000-350000000.00
Employee Number:
350~500
Ecer Certification:
Active Member
Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ... Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ...
Get in touch with us
Leave a Message, we will call you back quickly!