Payment Terms | T/T |
Packaging Details | safety carton pack or plywood box |
Standards | IEC 60335-1-clause 22.48 and IEC61770 |
Test Function | Test whether siphoning occurs when the sample is at the critical water level |
Vacuum Generation Method | vane vacuum pump |
Vacuum Degree Generated by the System | Not less than 0.085MPa |
Brand Name | KingPo |
Place of Origin | China |
View Detail Information
Explore similar products
IEC62368 Test Equipment And Measuring Equipment Hydraulic
IEC62133,UN38.3,UL2054 Battery Testing Equipment 6KW
Ingress Protection Testing Equipment Compliance With IEC 60529
ISO 9360-1 Medical Test Equipment Weighing Accuracy Of ±0.1 G
Product Specification
Payment Terms | T/T | Packaging Details | safety carton pack or plywood box |
Standards | IEC 60335-1-clause 22.48 and IEC61770 | Test Function | Test whether siphoning occurs when the sample is at the critical water level |
Vacuum Generation Method | vane vacuum pump | Vacuum Degree Generated by the System | Not less than 0.085MPa |
Brand Name | KingPo | Place of Origin | China |
High Light | IEC 60335-1-clause 22.48 and IEC61770 Standards Anti-siphon Test Device ,0.085MPa Vacuum Degree Battery Testing Equipment ,20L Surge Tank Vacuum Test System |
1. Equipment Overview:
This equipment complies with IEC 60335-1-clause 22.48 and IEC61770 standards and is specifically designed for testing the anti-siphon performance of water inlet valves. A transparent tube with a diameter similar to the product's inner diameter is installed between the sample and the front end of the equipment's vacuum machine. The tube is at least 500mm long and immersed in water to a depth of at least 25mm (equipped with a lifting platform for easy adjustment). This tube is used to observe the height of the water flow sucked in during the siphon test. The vacuum state of the water supply pipeline is simulated through the equipment's vacuum system to detect whether the water inlet valve has siphoning. The equipment is driven by a vacuum pump and controlled by a PLC.
2. Technical Parameters:
(1) Test Station: Single station ;
(2) Test Function: Test whether siphoning occurs when the sample is at the critical water level ;
(3) Vacuum Generation Method: Vane vacuum pump;
(4) Vacuum Degree Generated by the System: Not less than 0.085MPa ;
(5) Surge Tank Capacity: 20L;
(6) Operation Time: 0~999 seconds (adjustable;
(7) Machine Power Supply: AC 220V, 50HZ.
3. Functional Configuration:
(1) Machine Description: Aluminum profile frame structure, cold plate painted and sealed;
(2) Transparent acrylic water tank: 1 piece, made of acrylic, rust-resistant and corrosion-resistant, test water can be recycled;
(3) Software system: The machine adopts Mitsubishi PLC master control and Weiluntong 7-inch touch screen operation interface;
(4) Use a vacuum pump to generate vacuum, and the system vacuum degree should not be less than 0.085MPa ;
(5) The chassis is equipped with a surge tank to ensure test stability;
(6) A manual control box is also provided to facilitate visual inspection of the liquid level during operation.
Company Details
Business Type:
Manufacturer,Trading Company,Exporter,Seller
Year Established:
2000
Total Annual:
8000000-1500000
Employee Number:
50~200
Ecer Certification:
Verified Supplier
.gtr-container { font-family: 'Arial', sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin: 25px 0 15px 0; padding-bottom: 8px; border-bottom: 2px ... .gtr-container { font-family: 'Arial', sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin: 25px 0 15px 0; padding-bottom: 8px; border-bottom: 2px ...