Payment Terms | L/C, T/T, Western Union |
Supply Ability | 25 per month |
Delivery Time | 30-35 business days after received the payment |
Packaging Details | Wooden packing |
Product name | Environmental Stress Screening Test Chambers |
Test Space | 335L |
Internal size | 800×650×650mm (W*D*H) |
External size | 1800mmx2500mmx2300mm(W*D*H) |
Power supply | AC380V±10%,50Hz±1 four wire three phase+ earth wire(3/N/PE),Earthing resistance<4Ω |
Max. Power | 65KW |
Max. Currency | 110A |
Cooling Method | Water-Cooled |
Brand Name | Envsin |
Model Number | ETS6340S3 |
Certification | CE and ISO |
Place of Origin | China |
View Detail Information
Explore similar products
28m3 Programmable Control Climatic Test Chamber For Temperature Test
380V Environmental Stress Screening Test Chambers
Multifunctional 180 Degree Climatic Test Chamber Temperature And Humidity
10%~98% rh Humidity Range -40·180℃ Climate Test Chamber for Electronic Aeropace
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 25 per month |
Delivery Time | 30-35 business days after received the payment | Packaging Details | Wooden packing |
Product name | Environmental Stress Screening Test Chambers | Test Space | 335L |
Internal size | 800×650×650mm (W*D*H) | External size | 1800mmx2500mmx2300mm(W*D*H) |
Power supply | AC380V±10%,50Hz±1 four wire three phase+ earth wire(3/N/PE),Earthing resistance<4Ω | Max. Power | 65KW |
Max. Currency | 110A | Cooling Method | Water-Cooled |
Brand Name | Envsin | Model Number | ETS6340S3 |
Certification | CE and ISO | Place of Origin | China |
High Light | 335L Environmental Test Chambers ,SAE-J1211 Environmental Test Chambers ,335L Climatic Test Chamber |
335L Environmental Stress Screening Test Chambers Water-Cooled Climatic Test Chamber
The chamber used to test samples of non-heat dissipation or low heat dissipation. For test specimen with heat dissipation, the heat dissipating power can not exceed the cooling capacity of refrigeration system, otherwise it will affect the chamber temperature conversion speed and capacity. It is proposed test sample’s heat is less than 300W.
Test Space | 335L | ||
Internal size | 800*650*650mm(W×D×H) | ||
External size | 1800mm*2500mm*2300mm (W*D*H) | ||
Power supply | AC380V±10%,50Hz±1 four wire three phase+ earth wire(3/N/PE),Earthing resistance<4Ω | ||
Max. Power | 65KW | ||
Max. Currency | 110A | ||
Cooling Method | Water-Cooled | ||
System structure | Three part structure:immobile independent test area.Preheating area. Precooling area | ||
Installation Site |
| ||
Cooling water | Water Temp:5℃≤Water Temp≤28℃ reach all technical index, 28℃<Water Temp≤33℃ function well(cooling time will change); Water source Temp ≤10℃,need to prevent condensate water arise | 1:If test chamber adopt air-cooled,no need cooling water
2: If user need build cooling cycle water system, cooling tower specification≥15 ton or condensing unit refrigerating capacity≥40KW(20℃)
3:Cooling water system should be GB50050-1995 industrial cycling cooling water treatment design regulation standard | |
Water flow:≥15 ton/h | |||
Pipe diameter:G2.5 inches ×2 | |||
hydraulic pressure:0.3MPa~0.6MPa | |||
Hydraulic Pressure Difference:≥0.2MPa | |||
Water quality requirement:GB50050-1995 | |||
Air compression | Compressed air supply pressure:0.6MPa~0.7MPa Humidity of compressed air under Pneumatic use:≤30g/m³ Humidity of compressed air under dry air use:≤1.5g/m³ |
Working chamber temp shock test parameter | Thermal Shock Test Chambers--S2:
Low-High+Room Temperature Shock Test Chamber-S3:
| Note: 1.Testing with no load, meeting GB/T5170-2008, if no other special notice.
2.Temp. range in 0℃~+60℃, setting Shock temp. and RAMP Environmental Stress Screening function are disapprove.
3. Air cooled test chamber test data at Ambient Temp. 25℃, good ventilation condition;35℃≥RT>25℃ function well; low temp range, cooling rate and thermal load capacity will be affected by the changeable environment temperature.
4.Water cooled test chamber test data at water temp ≤28℃, Hydraulic pressure 0.3MPa~0.6Mpa, Hydraulic Pressure Difference≥0.2Mpa | ||||||||||
Preheat temp. | Temp. SV: +50℃~+220℃ Temp rise time: RT→+220℃ 50min | |||||||||||
Precool temp. | Temp. PV:﹣75℃~+70℃ Temp. reduction time: RT-75℃ 60min | |||||||||||
Temp. recovery time | <15min(measure in air outlet) | |||||||||||
Test standard
| Experiment standard-S2: GB/T2423.22 MIL STD 202F, method 107G IEC 60068-2-14, Test Na BS 2011 DIN 40046, Test Na JESD22-A101-A | Experiment standard-S3: GJB 150.5-1986 MIL STD 883H MIL STD 202G IEC 60068-2-14 JIS C 60068-2-14 JASO D 014–4 EIA JED-2531A | ||||||||||
Environmental Stress Screening Test Standard: IEC 60749-25(JESD22-A104D) IEC 60068-2-14NB(JIS C0025NB) IEC 61747-5(EIA JED-2531A) JESD22-A105-B IPC-9701 SAE-J1211 | ||||||||||||
|
Company Details
Business Type:
Manufacturer
Year Established:
2005
Total Annual:
$2.5 Million-US$5 Million
Employee Number:
>500
Ecer Certification:
Verified Supplier
For over 20 years, Envsin has been a trusted provider of environmental simulation and reliability testing solutions. We’ve served more than 170 Fortune 500 companies and over 1,000 small and medium-sized enterprises across 37 countries worldwide. Our expertise spans the development and pr... For over 20 years, Envsin has been a trusted provider of environmental simulation and reliability testing solutions. We’ve served more than 170 Fortune 500 companies and over 1,000 small and medium-sized enterprises across 37 countries worldwide. Our expertise spans the development and pr...
Get in touch with us
Leave a Message, we will call you back quickly!