Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Zion Communication TC Digital Temperature Unit with NTC Sensor","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/1a\/78\/819719464e80be64f7c5b3eb91b6-200x200-1\/zion_communication_tc_digital_temperature_unit_with_ntc_sensor.jpg","attrs":{"Brand Name":"Zion communication","Model Number":"TC Digital Temperature Unit","Power supply":"220VAC+ 10%\/-15% , 50\/60Hz","Power consumption":"\u22643W"}}
{"title":"FTTH SMC 96F Capacity Cross Connect Cabinet SC FC Connector Type","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/b8\/8f\/dd41f49606eae7a4096f02f02cdf-200x200-1\/ftth_smc_96f_capacity_cross_connect_cabinet_sc_fc_connector_type.jpg","attrs":{"Brand Name":"Zion communication OR OEM","Model Number":"Optical System Equipment","Certification":"ISO, CE, RoHS, UL","Place of Origin":"CHINA"}}
{"title":"N\/A Splitter 106kpa Fiber Cross Connect Cabinet 144F Capacity","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/46\/3e\/e3b14190d1f8d6016511db848f5c-200x200-1\/n_2fa_splitter_106kpa_fiber_cross_connect_cabinet_144f_capacity.jpg","attrs":{"Brand Name":"Zion communication OR OEM","Model Number":"Optical System Equipment","Certification":"ISO, CE, RoHS, UL","Place of Origin":"CHINA"}}
{"title":"FTTH 288F Fiber Cross Connect Cabinet Outdoor SMC Material","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/66\/2f\/90e25af66abfa9ac669920bcee94-200x200-1\/ftth_288f_fiber_cross_connect_cabinet_outdoor_smc_material.jpg","attrs":{"Brand Name":"Zion communication OR OEM","Model Number":"Optical System Equipment","Certification":"ISO, CE, RoHS, UL","Place of Origin":"CHINA"}}
{"title":"Gray Outdoor 576F Fiber Optic Cross Connect Cabinet For FTTH","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/dd\/93\/4c8f0a103e78da0a0231453a222a-200x200-1\/gray_outdoor_576f_fiber_optic_cross_connect_cabinet_for_ftth.jpg","attrs":{"Brand Name":"Zion communication OR OEM","Model Number":"Optical System Equipment","Certification":"ISO, CE, RoHS, UL","Place of Origin":"CHINA"}}
{"title":"Lock & Racks for Network Cabinets | Data Center Accessories | Server Rack | Zion","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/aa\/b7\/ec6eab57cbd391ec13c0f02c99a2-200x200-1\/lock_26_racks_for_network_cabinets_7c_data_center_accessories_7c_server_rack_7c_zion_communiation_china.jpg","attrs":{"Brand Name":"Zion communication OR OEM","Model Number":"Data Center Equipment","Certification":"ISO, CE, RoHS, UL","Place of Origin":"CHINA"}}
{"title":"Cooling for Network Cabinet | Server Rack | Data Center Accessories | Zion","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/2a\/64\/8f4adafe342de4d71ce1c024d1de-200x200-1\/cooling_for_network_cabinet_7c_server_rack_7c_data_center_accessories_7c_zion_communiation_china_supplier.jpg","attrs":{"Brand Name":"Zion communication OR OEM","Model Number":"Data Center Equipment","Certification":"ISO, CE, RoHS, UL","Place of Origin":"CHINA"}}
· Power supply: 220VAC+ 10%/-15% , 50/60Hz. · Temperature measuring range: -50℃ ~99℃. · Resoluton: 1℃. · Refrigeration output contact capacity: 10A/277VAC. · Senssor error delay time: 1min. . · Safe level: 1P65. · Operation humidity: 20~85%(no condensate). · Power consumption: ≤3W. · Temperature controling range: -40℃ ~50℃. · Accuracy: -50℃ ~70℃, ±1℃, ±1 ℃ at others can drive single phase compressor≤1/2HP. · Sensor: NTC. · Operation temperature: -30℃~75℃.
Detalis:
Key operation
· Check parameter set value:
Press ▲ and then loosen to display the set upper limit; Press and then loosen▼to display the.
Modify parameter set value
· Press set for more than 3s to cnter into parameter modifying status the last,display the last adjusted menu after electrified with parameter modifying indicator light on.
· Press ▲ or▼to go forward or backward the menu item; press set to display the current.
Parameter set value
· Press set and ■ or ■ simultaneously can adjust the current parameter set value;press set and ■ simultaneously more than 1s will increase current parameter set value quickly; press set and ■ simultaneously more than 1s will decrease current parameter set value puickly;
· Press rst or no key operation in 30s will save the modified parameter and retutn to normal temperature display status.
Restore the parameter setting
· When electrify the controller,first check the parameter setting,if parameter setting is wrong, LED display E1 with buzzer sound,at this time press Set will restore default parameter setting.
· Advise to reset the parameter.
Front panel
Key-press function
Key-press
Reference
Performance
SET
Check compressor protection time
Display current menu set value
SET…3 seconds
Enter into parameter modification
Rst
Check temperature exceeding value
Quit from parameter modification
▲
Temperature upper limits checking
Menu items go backwards
▼
Temperature lower limits checking
Menu items go forwards
SET+▲
Parameter values increase by degrees
SET+▼
Parameter values decrease by degrees
Control output
· Compressor:When the storage temp.Is higher than set temp.Upper limit,compressor starts, lower than set temp. Lower limit,compressor stops, When sensor errir, compressor works proportionably as on -15 minutes off -30 minutes. After electrified or compressor stops . Compressor restart-up is allowed after running out of compressor protection time.
· Alarm:While temp.exceeding valus is not 0.LED blinkingly displays current temperature when storage temperature is higher than set temperature upper limip +exceeding temp value or lower than set lower limit-exceeding temp. value. When rumming out of the exceeding temp.limit alarm delay after electrified. exceeding temp.limit alarm starts with buzzer sound,and alarm cancel when temperature return to normal temperature LED blinkingly Display E1 with buzzer sound when memorizer error; display E2 with buzzer sound when sensor error, Display HH when temp. Higher than 99°C and lower than 120’C. Press any key to cancel alarm sound, but alarm status remains.
Lndicator light description
Indicator light
Staus
Input Connector Type
Cool
Always on
Compressor cutput
Cool
Flashes
Compressor cutput delay
Set
Always on
Parmeter modification status
Wire diagram
Key-press function
Item
Funtion
Fetting range
Unit
Default
F1
Upper limit
F2~+5
°C
-10
F2
Lower limit
-40~F1
°C
-20
F3
Temperature calibration
-5~5
°C
0
F4
Compressor protection time
0~9
Min
3
F5
Exceeding temperatuer value
0~50, set value as 0 to cancel alam
°C
15
F6
Exceeding temperature alarm delay time
F2~+5
°C
20
Safety regulations
· Danger: Strictly distinguish the sensor down-lead,power wire and output relay interface from one another,prohibit wrong connections or overloading the relay. All connections should be modified under electricity cut-off.
· Warning: Prohibit to use the machine in water or under the environment of ower damp, high temperature,string electromagnetism interference ir string corrosion.
· Caution: The power supply should conform to one labeled on the machine,and ensure the stability of the power voltage. Sensor down-lead and power should be kept for a proper distance to avoid possible interferences.
Error Code
Code
Reason
Staus
E1
Memorizer error
Alarm,machine dose not work
E2
Sensor error
Alarm.Comressor starts/ stop proportionably
HH
Exceeding temp, display limit
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Year Established:
1999
Total Annual:
80 Million-100 Million
Employee Number:
400~500
Ecer Certification:
Verified Supplier
Zion Communications is a professional manufacturer and supplier of
the products for fiber systems & copper cabling systems.
We provide products and services to our customers in 2 ways.
1, OEM customized production according to your requirements
2, Standardized products and services accordi... Zion Communications is a professional manufacturer and supplier of
the products for fiber systems & copper cabling systems.
We provide products and services to our customers in 2 ways.
1, OEM customized production according to your requirements
2, Standardized products and services accordi...