Payment Terms | T/T |
Supply Ability | 1000pcs/month |
Delivery Time | 15-30days |
pattern | Canister compression column load cell |
capacity | 10t, 20t, 30t, 40t, 50t |
output | 2mv/v |
INTERCHANGEABLE BRAND | Mettler Toledo Load Cell 0782GD |
Application | Truck Scale |
MATERIAL | STAINLESS STEEL |
7.IP Protection standard | IP68 |
Accuracy class | C2,C3 |
Cable | 12m |
size | 10t:diameter:76mm height:150mm |
Brand Name | inntronic |
Model Number | IN-GD |
Place of Origin | China |
View Detail Information
Explore similar products
Load Cell TC014 Compression Alloy steel IP68 weight sensor 470t C3 for truck
Load Cell IN-SDS 50 Ton Canister Compression Column Alloy Steel weighbridge
Load Cell CL016 100Klb Stainless Steel weighbridge weighing force sensor For
Load Cell IN-C16 Truck Scale Analog Column weight force sensor Alloy Steel 40t
Product Specification
Payment Terms | T/T | Supply Ability | 1000pcs/month |
Delivery Time | 15-30days | pattern | Canister compression column load cell |
capacity | 10t, 20t, 30t, 40t, 50t | output | 2mv/v |
INTERCHANGEABLE BRAND | Mettler Toledo Load Cell 0782GD | Application | Truck Scale |
MATERIAL | STAINLESS STEEL | 7.IP Protection standard | IP68 |
Accuracy class | C2,C3 | Cable | 12m |
size | 10t:diameter:76mm height:150mm | Brand Name | inntronic |
Model Number | IN-GD | Place of Origin | China |
High Light | 20t canister type load cell ,30t canister type load cell ,truck scale load cells IP68 |
IN-GD IP68 10T- 50T Canister compression Load Cell FOR TRUCK SCALE interchangeable with toledo GD 30t 50t load cell
Advantages:
- Self-restoring function;
- Nominalloads:10t-50t ;
- Simple to install;
- Laser welded, IP68;
- Optimized for parallel connection by comer pre-adjustment;
- Meets EMC/ESD requirements According to EN 45 501;
interchangeable with mettler toledo GD 10t, 20t, 30t, 40t, 50t
Item | Unit | Parameter | ||||
Accuracy Class to OIML R60 |
| C2 | C3 | |||
Maximum Capacity (Emax) | t | 10, 20, 30, 40, 50 | ||||
Minimum LC Verification Interval (Vmin) | % of Emax | 0.0200 | 0.0100 | |||
Sensitivity(Cn) / Zero Balance | mV/V | 2.0±0.002/0±0.02 | ||||
Temperature Effect on Zero Balance (TKo) | % of Cn/10K | ±0.02 | ±0.0170 | |||
Temperature Effect on sensitivity (TKc) | % of Cn/10K | ±0.02 | ±0.0170 | |||
Hysteresis Error (dhy) | % of Cn | ±0.0270 | ±0.0180 | |||
Non-linearity (din) | % of Cn | ±0.0250 | ±0.0167 | |||
Creep (dcr) Over 30 min. | % of Cn | ±0.030 | ±0.0167 | |||
Input (RLC) & Output Resistance (Ro) | Ω | 1160±10&1000±3 | ||||
Nominal Range of Excitation Voltage (Bu) | V | 5-12 | ||||
Insulation Resistance (Ris) at 50 Vdc | MΩ | ≥5000 | ||||
Service Temperature Range (Btu) | ℃ | -30…+70 | ||||
Safe Load Limit (EL) & Breaking Load (Ed) | % of Emax | 150 & 200 | ||||
Protection Class According to EN 60 529 (IEC 529) |
| IP68 | ||||
Material: measuring element + housing |
| Stainless or Alloy Steel + Stainless Steel | ||||
Maximum Capacity (Emax) | t | 10 | 20 | 30 | 40 | 50 |
Min. scale Verification (emin) according to En45 501 [...#=max. Number of Load Cells] |
Kg | 5 [6#] | 5 [6#] 10 [8#] | 10 [8#] | 10 [6#] 20 [8#] | 10 [4#] 20 [10#] |
Recommended Maximum Weighing Capacity of Scale | T | 30 | 50 80 | 100 | 100 150 | 100 200 |
Deflection at Emax (snom), approx. | Mm | 0.55 | 0.65 | 0.75 | 0.85 | 0.85 |
Weight(G), approx. | Kg | 1.9 | 2.1 | 2.3 | 2.5 | 2.7 |
Cable: Diameter: φ6mm Length | m | 12 | 12 | 14 | 16 | 16 |
Dimension
A load cell is a highly accurate and reliable device used to measure weight or force. It is commonly used in industrial and commercial applications where precise weight measurements are required. Load cells are designed to convert the force applied to them into an electrical signal that can be easily measured and recorded.
At its core, a load cell consists of a metal body with strain gauges attached to it. When a force is applied to the load cell, the metal body deforms slightly, causing the strain gauges to change their resistance. This change in resistance is then converted into an electrical signal that can be read by a computer or other device.
Load cells come in a variety of shapes and sizes, and can be used in a wide range of applications. They are commonly used in weighing scales, industrial machinery, and even in medical equipment. Load cells are known for their high accuracy and reliability, making them an essential tool for many industries.
If you are looking for a high-quality load cell, it is important to choose a reputable supplier. Look for a supplier that offers a wide range of load cells, and that has a proven track record of providing reliable and accurate products. With the right load cell, you can ensure that your weight measurements are always accurate and reliable, helping you to improve your processes and increase efficiency.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2012
Total Annual:
1500000-2000000
Ecer Certification:
Site Member
INNOVATION ELECTRONIC CO..,LTD Focus on Weighing and Static solution in Packing industry! In the past tens of years, we established very good relationship with wide range of suppliers and customers in weighing and static products especially in packing industry and also investigated in o... INNOVATION ELECTRONIC CO..,LTD Focus on Weighing and Static solution in Packing industry! In the past tens of years, we established very good relationship with wide range of suppliers and customers in weighing and static products especially in packing industry and also investigated in o...
Get in touch with us
Leave a Message, we will call you back quickly!