China 100A 2p 4p Water Immersion Alarm Leakage Current Circuit Breaker Multifunction
China 100A 2p 4p Water Immersion Alarm Leakage Current Circuit Breaker Multifunction

  1. China 100A 2p 4p Water Immersion Alarm Leakage Current Circuit Breaker Multifunction
  2. China 100A 2p 4p Water Immersion Alarm Leakage Current Circuit Breaker Multifunction
  3. China 100A 2p 4p Water Immersion Alarm Leakage Current Circuit Breaker Multifunction
  4. China 100A 2p 4p Water Immersion Alarm Leakage Current Circuit Breaker Multifunction

100A 2p 4p Water Immersion Alarm Leakage Current Circuit Breaker Multifunction

  1. MOQ: 500pcs
  2. Price: USD21.45
  3. Get Latest Price
Supply Ability 1000PCS/DAY
Delivery Time 25DAYS
Packaging Details EXPORTING CARTON
Pole 2P, 4P
Rated Current 6A,10A,16A,20A,25A,32A, 40A,63A,80A,100A
Residual current 30,100,300mA
Breaking capacity 6KA
Function multi funaction
Brand Name SONTUOEC, SONTUNE,IMDEC, STUOEC
Model Number STFS2-100
Certification CE
Place of Origin WENZHOU,CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 1000PCS/DAY Delivery Time 25DAYS
Packaging Details EXPORTING CARTON Pole 2P, 4P
Rated Current 6A,10A,16A,20A,25A,32A, 40A,63A,80A,100A Residual current 30,100,300mA
Breaking capacity 6KA Function multi funaction
Brand Name SONTUOEC, SONTUNE,IMDEC, STUOEC Model Number STFS2-100
Certification CE Place of Origin WENZHOU,CHINA

The working reference temperature of RCBO is 30ºC , when the ambient temperature changes, its setting value should be corrected. If multiple RCBOs are installed in a closed box and the temperature inside the box rises, the rated current should be multiplied by the
derating factor of 0.8.
The "N" line on the RCBO should be connected to the neutral line to make the electronic circuit work normally and play a prote- ctive role.
It is not allowed to use the method of short-circuiting the phase line to the neutral line or the phase line to the phase line to carry out the short-circuit protection capability test on the RCBO.
Recommended selection principles
General selection principles
a)The rated working voltage of RCBO ≥ the rated voltage of the line.
b) The rated current of RCBO is 1.1-1.25 times the load current calculated by the line.
c)The rated short-circuit breaking capacity of RCBO ≥ the maximum short-circuit
current that may appear in the line.
d)RCBO instantaneous release setting current ≤ 0.8 times the end of the line phase
-to-ground or phase-to-phase short circuit current.
e) Single-phase rated current of electric heaters, refrigerators and incandescent la-
mps at a given voltage and power In=P/U; three-phase rated current In=P/1.732U.
RCBO residual current is generally selected as 30mA, which is used as personal
contact protection.
To install and use the product, please read the retention manual.

 

Model STFS2-100 Electroic type
Residual Current characterstics AC
Standard IEC/EN 61009-1
Rated sensitivityl△n 0.03,0.1,0.3
Pole No Pole: 1P+N+PE; 3P+N+PE
Rated Current(A) 6A,10A,16A,20A,25A,32A, 40A,63A,80A,100A
Rated Voltage(V) 240/415V ;230/400V
Rated residual operating current 10ma,30ma,100ma,300ma,500ma
Rated conditional residual short circuit current 6KA
Electro-machanical endurance over 4000 cycles
FUNCTION:

 

leakage protection,

Overload current protect,

short circuit protection,

under voltage protection,

over voltage protection,

Rated current/ Voltage adjustable,

Temperature protection,

Water ingress alarm and so on.

 

SURROUNDING AIR TEMPERATURE:

1.The ambient air temperature shall not be lower than -5 1C, not higher than+40 C, and the daily average value shallnot exceed+35 C.

2. Altitude: The altitude of the installation site shall not exceed 2000m.

3.Atmospheric conditions

The air is clean, and at a maximum temperature of+40 'C, the relative humidity of the air is not high More than 50%. Higher relative humidity is allowed at lower temperatures, such as at+20 C,

The relative humidity should not exceed 90%. Due to occasional moderate condensation caused by temperature changes, Attention should be paid to taking appropriate measures.

4. Installation Category Installation categories are lI and III

 

 

Current and Number of Poles

100A: This indicates that the RCBO is rated at 100 amps. The current rating is the maximum value of current that the circuit breaker can carry continuously without causing overheating or damage.

 

2p, 4p: The “p” here stands for the number of poles, i.e., the number of circuit phases to which the circuit breaker can be connected. 2p means that the circuit breaker can be connected to two circuit phases (usually Fire and Zero), whereas 4p means that it can be connected to four circuit phases (usually three-phase Fire and Zero).

 

Multifunctional

Multifunctional indicates that this 100A 2p 4p Multifunctional RCBO is equipped with a variety of protection functions. In addition to basic overload and short-circuit protection, it can also provide leakage protection, undervoltage protection, overvoltage protection, and so on. temperature protection,Water ingress alarm,Adjustable current and voltage.These protections allow the RCBO to provide more comprehensive protection for circuits and equipment.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2005

  • Total Annual:

    350-500

  • Employee Number:

    50~100

  • Ecer Certification:

    Site Member

WENZHOU SANTUO ELECTRICAL Co., Ltd.(Before:YUEQING SHANTUO ELECTRICAL CO.,LTD.) is one of manufactories that specialize in manufacturing Circuit Breaker, AC CONTACTOR, Thermall Relay,Magnetic Starter(DOL),Solid State Relay,Distribution Case, Voltage Regulator  is located in Liushi, Wenzhou... WENZHOU SANTUO ELECTRICAL Co., Ltd.(Before:YUEQING SHANTUO ELECTRICAL CO.,LTD.) is one of manufactories that specialize in manufacturing Circuit Breaker, AC CONTACTOR, Thermall Relay,Magnetic Starter(DOL),Solid State Relay,Distribution Case, Voltage Regulator  is located in Liushi, Wenzhou...

+ Read More

Get in touch with us

  • Reach Us
  • WENZHOU SANTUO ELECTRICAL CO.,LTD.
  • No. 3999 LiuJiang Road, Liushi, Yueqing, Wenzhou, Zhejiang, China
  • https://www.contactorcircuitbreaker.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement