Packaging Details | Standard package |
Accuracy | 0.2% FS |
measurement speed | 10 times per second |
Face-plate | 2-bit LED(Channel number)+ 4-bit LED(Measured value) |
Alarm | Standard 2 points can be extended to 4 points. 250V AC/3A Resistive load |
Power supply | 100-240V AC 50/60 Hz or 10-24V AC 50/60 Hz;10-24V DC |
Printing Function | Fission Printing or Integrative Printing |
Brand Name | CSPPM |
Model Number | PPM-TC1CL |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
0~15MPa PPM-T117A Vehicle-Mounted Engines Pressure Sensor
0 ~ 1000bar PPM-T227A Wind Power Hydraulic And Pneumatic Control Pressure
Explosion Proof PPM-T230E-222 Wellhead Pressure Equipment Pressure Transmitter
PPM-T232C 0 ~ 6 MPa 150 MPa Polyurethane Equipment Pressure Transmitter
Product Specification
Packaging Details | Standard package | Accuracy | 0.2% FS |
measurement speed | 10 times per second | Face-plate | 2-bit LED(Channel number)+ 4-bit LED(Measured value) |
Alarm | Standard 2 points can be extended to 4 points. 250V AC/3A Resistive load | Power supply | 100-240V AC 50/60 Hz or 10-24V AC 50/60 Hz;10-24V DC |
Printing Function | Fission Printing or Integrative Printing | Brand Name | CSPPM |
Model Number | PPM-TC1CL | Certification | CE |
Place of Origin | China | ||
High Light | 10V AC Circuit Check Measure Alarm Instrument ,0.2% FS Circuit Check Measure Alarm Instrument ,10V AC Circuit Check Instrument |
Intelligent Circuit Check Measure Alarm Instrument
PPM-TC1CL Intelligent Circuit Check & Measure Alarm Instrument applies to checking, measurement and alarm of 5~80 points process quantity. It is adapted to signals of thermocouple, RTD, DC current, DC voltage sensors and re-transmitters.
1. Basic intrinsic error is less than 0.2%, indication range is -1999~9999.
2. The signal type, range, alarm value of each channel can be set separately.
3. Digital filtering time coefficient of each channel, which can improve anti-interference ability, can be set separately.
4. Zero and full scale correction, which can effectively reduce sensor error to improve measuring accuracy of the system, can be set separately.
5. Useless channels can be shut at will.
6. The 2nd grade parameter. The 2nd grade parameter is controlled by security code to prevent misoperation. Parameter copying function, which can greatly reduce workload of parameter setting, is also available.
7. Unique and practical alarm function, which is the connection to the LCU multiple controlling unit, can actualize alarm output of every channel.
8. Manual, timing, alarm start printing.
9. High-speed, high-efficiency communication interface can greatly reduce communication time.
Code Description | ||||||||||
PPM-TC1CL- | 8~80 channel;0.2% accuracy;measurement speed:10 times per second | |||||||||
Dimension | A | 160×84×142 tapping:152×76 | ||||||||
B | 84×160×142 tapping:76×152 | |||||||||
C | 160×160×182 tapping:152×152 | |||||||||
D1 | 318×104×300 desktop type | |||||||||
D2 | 318×104×300 tray use tapping:312×96 | |||||||||
Faceplate | 2-bit LED(Channel number)+ 4-bit LED(Measured value) | |||||||||
Channels(Channels of A/B type ≤32;Channels of C,D1,D2≤80) |
08 | 8 channels | ||||||||
16 | 16 channels | |||||||||
24 | 24 channels | |||||||||
32 | 32 channels | |||||||||
40 | 40 channels | |||||||||
48 | 48 channels | |||||||||
56 | 56 channels | |||||||||
64 | 64 channels | |||||||||
72 | 72 channels | |||||||||
80 | 80 channels | |||||||||
Input Signal | R | All channels are RTD,Pt100,Cu100,Cu50,BA1,BA2,G53 | ||||||||
E | All channels are Thermocouple,K,S,R,B,N,E,J,T | |||||||||
B |
All channels are DC current signals((4-20)mA/(0-10)mA/(0-20)mA)Or DC voltage signals((0-5)V/(1-5)V). Notification of current or voltage signal channel is needed on order. |
|||||||||
X | Input signals are RTD and Thermocouple mix | |||||||||
L | Input signals are RTD, thermocouple, 4mA~20mA,0mA~10mA,1V~5V,0V~5V mix. Notification of current or voltage signal channel is needed on order. | |||||||||
Alarm | Standard 2 points can be extended to 4 points. 250V AC/3A Resistive load | |||||||||
Communication Interface (Communication speed:2400,4800,9600,19200) (Communication address:0-99) |
S1 | TC ASCII RS232 | ||||||||
S2 | TC ASCII RS485 | |||||||||
M1 | Modbus-RTU RS232 | |||||||||
M2 | Modbus-RTU RS485 | |||||||||
Printing Function (Only for S1,S2 type) |
P1 | Fission Printing | ||||||||
P2 | Integrative Printing | |||||||||
Power supply | V0 | 100-240V AC 50/60 Hz | ||||||||
V1 | 10-24V AC 50/60 Hz;10-24V DC |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
20
Total Annual:
1 Million-2.5Million
Employee Number:
60~100
Ecer Certification:
Active Member
CSPPM specialized in manufacturing and selling pressure sensors, pressure transmitters, liquid level sensor, temperature transmitter, automation instrument and system. Based on Central South University (CSU), implemented the quality management system of ISO9001. declared several of national inventio... CSPPM specialized in manufacturing and selling pressure sensors, pressure transmitters, liquid level sensor, temperature transmitter, automation instrument and system. Based on Central South University (CSU), implemented the quality management system of ISO9001. declared several of national inventio...