China Food Safety Enrofloxacin ELISA Test Kit Rapid Assay Protocol With Strong
China Food Safety Enrofloxacin ELISA Test Kit Rapid Assay Protocol With Strong

  1. China Food Safety Enrofloxacin ELISA Test Kit Rapid Assay Protocol With Strong
  2. China Food Safety Enrofloxacin ELISA Test Kit Rapid Assay Protocol With Strong
  3. China Food Safety Enrofloxacin ELISA Test Kit Rapid Assay Protocol With Strong

Food Safety Enrofloxacin ELISA Test Kit Rapid Assay Protocol With Strong

  1. MOQ: 5 kits
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 100 kits per month
Delivery Time 5-7 days
Packaging Details color packing
Specimen Meat/Liver/Kidney/Fish/Shrimp
Size 96 test
Package color packing
Shelf life one year
Keywords Enrofloxacin test kit , elisa kit , Enrofloxacin elisa test kit
Sensitivity 0.1 ng/ml
Brand Name REAGEN
Model Number RND99041
Certification
Place of Origin USA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 100 kits per month
Delivery Time 5-7 days Packaging Details color packing
Specimen Meat/Liver/Kidney/Fish/Shrimp Size 96 test
Package color packing Shelf life one year
Keywords Enrofloxacin test kit , elisa kit , Enrofloxacin elisa test kit Sensitivity 0.1 ng/ml
Brand Name REAGEN Model Number RND99041
Certification Place of Origin USA
High Light drug residue testing kitsfood safety testing kits

Enrofloxacin ELISA Test Kit

Product Description

REAGEN Doxycycline ELISA Test Kit is a competitive enzyme immunoassay for the quantitative analysis of doxycycline in egg, honey, meat, fish , shrimp and milk.

 

The unique features of the kit are:

  • High recovery (75-120%), rapid and cost-effective extraction methods.

  • High sensitivity (0.1ng/g or ppb) and low detection limit for samples.

  • High reproducibility.

  • A quick ELISA assay (less than 1 hours regardless of number of samples).

 

Procedure Overview

The method is based on a competitive colorimetric ELISA assay. The doxycycline-BSA has been coated in the plate wells. During the analysis, sample and the doxycycline antibody are added along with secondary antibody, tagged with a peroxidase enzyme. If the doxycycline residue is present in the sample, it will compete for the doxycycline antibody, thereby preventing the antibody from binding to the doxycycline-BSA attached to the well. The resulting color intensity, after addition of the HRP substrate (TMB), has an inverse relationship with the doxycycline residue concentration in the sample.

 

 

Kit Contents, Storage and Shelf Life

REAGEN Doxycycline ELISA Test Kit has the capacity for 96 determinations or testing of 42 samples in duplicate (assuming 12 wells for standards). Return any unused micro-wells to the foil bag and reseal them with the desiccant provided in the original package. Store the kit at 2-8°C . The shelf life is 12 months when the kit is properly stored.

 

Kit Contents Amount Storage
Doxycycline-Coated Plate 1 x 96-well plate (8 wells x 12 strips) 2-8℃

Doxycycline Standards:

Negative control (white Cap tube)

0.1ng/mL (yellow Cap tube)

0.3 ng/mL (orange Cap tube)

0.9 ng/mL (pink Cap tube)

2.7 ng/mL (purple Cap tube)

8.1 ng/mL (blue Cap tube)

500ng/mL (Spiking, red Cap tube)

 

1.0 mL

1.0 mL

1.0 mL

1.0mL

1.0 mL

1.0 mL

1.0 mL

 

 

2-8℃

 

 

 

Doxycycline Antibody #1 6 mL 2-8℃
HRP-Conjugated Ab #2 6 mL
20X Wash Solution 30 mL
10X Sample Ext. Buffer 30 mL
Stop Buffer 12 mL
TMB Substrate 12 mL
 

If you are not planning to use the kit for over 1 month, storing Doxycycline Standard Stock, Doxycycline Antibody #1 and HRP-Conjugated Ab #2 at -20℃ or in a freezer is recommended.

 

Sensitivity

Sample Type Detection Limit (ng/g or ppb)
Egg 1.5
Honey/Milk 1
Meat/Fish/Shrimp 1

 

Specificity

Analytes Cross-Reactivity (%)
Doxycycline 100
Chlortetracycline 24
Oxytetracycline 21
Tetracycline 15
 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2012

  • Total Annual:

    15000000-20000000

  • Employee Number:

    50~80

  • Ecer Certification:

    Verified Supplier

REAGEN INC For more than 13 years REAGEN has been focusing on best-in-class PCR, NGS, ELISA, and lateral flow rapid test kits for human and animal infectious disease diagnostics, as well as for food safety testing. REAGEN develops and manufactures diagnostic kit s for the detection of infectious... REAGEN INC For more than 13 years REAGEN has been focusing on best-in-class PCR, NGS, ELISA, and lateral flow rapid test kits for human and animal infectious disease diagnostics, as well as for food safety testing. REAGEN develops and manufactures diagnostic kit s for the detection of infectious...

+ Read More

Get in touch with us

  • Reach Us
  • REAGEN LLC
  • 7098 Miratech Dr Ste 110 San Diego CA 92121 USA
  • https://www.elisatest-kits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement