China factories

China factory - Godson Technology Co., Ltd

Godson Technology Co., Ltd

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China ABS PC Non Maintained LED Camping Light 6W 600Lm Wall Mounting
China ABS PC Non Maintained LED Camping Light 6W 600Lm Wall Mounting

  1. China ABS PC Non Maintained LED Camping Light 6W 600Lm Wall Mounting
  2. China ABS PC Non Maintained LED Camping Light 6W 600Lm Wall Mounting
  3. China ABS PC Non Maintained LED Camping Light 6W 600Lm Wall Mounting
  4. China ABS PC Non Maintained LED Camping Light 6W 600Lm Wall Mounting

ABS PC Non Maintained LED Camping Light 6W 600Lm Wall Mounting

  1. MOQ: 50PCS
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Mains Supply AC220-240V-50/60Hz
Power 10 W
Duration Time 3 Hours
Recharge Period 16 Hours
Battery Size & Type lithium battery /Ni-CD/Ni-MH
Lanp Luminous Flux 1000Lm
Brand Name Godson or OEM
Model Number LED Camping Light GS-307
Place of Origin Guangdong, China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Mains Supply AC220-240V-50/60Hz
Power 10 W Duration Time 3 Hours
Recharge Period 16 Hours Battery Size & Type lithium battery /Ni-CD/Ni-MH
Lanp Luminous Flux 1000Lm Brand Name Godson or OEM
Model Number LED Camping Light GS-307 Place of Origin Guangdong, China (Mainland)
High Light 6W LED Camping Light600Lm LED Camping LightABS PC LED Camping Light


ABS/PC Non Maintained LED Camping Light 6W 600Lm Wall Mounting


Technical Specifications

 

Mains Supply
AC220-240V-50/60Hz
Power 10W
Duration Time 3 Hours
Recharge Period 16 Hours
Battery Size & Type Lithium battery
/Ni-CD/Ni-MH
CCT 6500k
Protection Class Class
Operating Temperature 0-40

 

 

Features

 

- Wall mounting
- battery, replaceable
-3 hours emergency duration

 

 

Materials
 
-Base:ABS/PC

 


Dimensions



 

Below is a list of 3 things to ask yourself when designing a system

 

1. What is the primary purpose of the emergency lighting system?

The primary purpose of an emergency lighting luminaires system is to provide illumination in locations where it is necessary for the safe conduct of business or during an emergency. The different types of emergency lighting systems are designed to meet the specific needs of each kind of environment.

 

2. Does my building need emergency lighting?

Every class (classes) 5, 6 (six), 7, 8 or 9 building with a floor area of more than 300m² must have emergency and exit lights.
 

3. Does my emergency lighting system comply with local Standards?

Emergency luminaires and exit signs standards must be adhered to when designing an emergency lighting system.

 

 

Monthly Testing
 

This only requires a short test to check that everything is working properly. Use the test key to ensure that all emergency lights are on when the mains power is off and check the enclosures to ensure they are clean and show no signs of damage. Once mains power is restored, check that they are fully charged again.

Also most emergency lights or exit signs have a small "test" button somewhere in the housing. You can press and hold this button for thirty seconds to test the bulb and battery. This method works fine if you have a small number of devices that can be easily accessed. The light should come on and stay at the same brightness level for a full 30 seconds. If the lights dim immediately, or if some bulbs do not work, then you should contact us to replace the bulbs or batteries in the fixture.


 

Why thirty seconds?
 

Many defective batteries only hold enough charge to fully light the bulb for a few seconds, but they lose power quickly. If you don't test for 30 seconds, you may find lights that work every month only to find that they go out within seconds of when you really need them. By testing the lights for at least 30 seconds, you can ensure that the batteries have more than just this type of "surface charge".

 

Annual Testing
 

Locate the circuit breaker or fuse that supplies power to the emergency light or exit sign. (If they are not properly marked, you may need to contact an electrician.) Turn off the circuit breakers and observe the lights to determine if they are working properly during the three-hour test period.


 

Why three hours?
 

It is important to test emergency lights annually for their full rated duration. Emergency lights should provide a minimum of 3 hours of illumination (which is usually the case), so they need to be tested for the full 3 hours to ensure they are still working at the end of the test.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Ecer Certification:

    Verified Supplier

  Godson Technology Co., Ltd. is a globally trusted supplier and manufacturer of emergency lighting battery, emergency lighting products, E-bike battery and power tool battery, whose batteries range covers Ni-Cd, Ni-MH, LiFePO4, Lead Acid, Lion-polymer and other relevant lithium batteries....   Godson Technology Co., Ltd. is a globally trusted supplier and manufacturer of emergency lighting battery, emergency lighting products, E-bike battery and power tool battery, whose batteries range covers Ni-Cd, Ni-MH, LiFePO4, Lead Acid, Lion-polymer and other relevant lithium batteries....

+ Read More

Get in touch with us

  • Reach Us
  • Godson Technology Co., Ltd
  • Unit 103B (Main Building), Building 4, No. 29 North Pier Road, Huang Pu Village, Haizhu District, Guangzhou, Guangdong, China ,510330
  • https://www.emergencylight-batteries.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement