China factories

China factory - WWHS Biotech.Inc(exclusive marketed by Dawin)

WWHS Biotech.Inc(exclusive marketed by Dawin)

  • China,Shenzhen
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China D-Dimer High Accuracy FIA POCT Rapid Quantitative Test Kit In Human Whole Blood
China D-Dimer High Accuracy FIA POCT Rapid Quantitative Test Kit In Human Whole Blood

  1. China D-Dimer High Accuracy FIA POCT Rapid Quantitative Test Kit In Human Whole Blood
  2. China D-Dimer High Accuracy FIA POCT Rapid Quantitative Test Kit In Human Whole Blood

D-Dimer High Accuracy FIA POCT Rapid Quantitative Test Kit In Human Whole Blood

  1. MOQ: 1000
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 10 Million a year
Delivery Time 7 Days
Packaging Details Colorful Paper Box
Product Name D-Dimer Rapid Test Kit
Storage Room Temperature
Sample Buffer 25 Vials
Manufacturer WWHS BIOTECH INC
Type POCT
Application Human
Usage Medical Hospital Clinical
Format Cassette
Package 25 Tests
Keywords High Sensitive, Super Stability
Brand Name WWHS
Model Number D-D
Certification ISO 13485, CE
Place of Origin CN

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 10 Million a year
Delivery Time 7 Days Packaging Details Colorful Paper Box
Product Name D-Dimer Rapid Test Kit Storage Room Temperature
Sample Buffer 25 Vials Manufacturer WWHS BIOTECH INC
Type POCT Application Human
Usage Medical Hospital Clinical Format Cassette
Package 25 Tests Keywords High Sensitive, Super Stability
Brand Name WWHS Model Number D-D
Certification ISO 13485, CE Place of Origin CN
High Light FIA D-Dimer Rapid Test KitHigh Accuracy D-Dimer Rapid Test KitD-Dimer Rapid Quantitative Test Kit

【Product name】 D-Dimer.pdf

D-Dimer Rapid Quantitative Test(Fluorescence immunoassay)

【Intended use】

This kit is used for quantitative determination of D-dimer in human whole blood and plasma.

【Inspection principle】

The principle of immunofluorescence chromatography was applied to the kit. The D-dimer antigen in the sample was first bound with the conjugated compound of fluorescent labeled D-dimer monoclonal antibody, then moved and combined with another D-dimer monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.

【Main components】

Name Quantity Component
Test card 25 It is composed of fluorescent pad (coated with fluorescent labeled D-dimer monoclonal mouse antibody), nitrocellulose membrane (coated with D-dimer monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample buffer 25(300μL/tube) Phosphate buffer
ID card 1 Record the standard curve information of this kit
 

 

【Reference interval】

By measuring 268 healthy people aged between 19 and 79, statistical analysis shows that the reference interval is less than 500 ng/ml. According to the characteristics of the local population, the reference intervals of the laboratories were established.

【Interpretation of results】

  1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
  2. For samples with D-dimer concentration lower than 40ng/ml and higher than 10000ng/ml, the detection results are reported as "< 40ng/ml" and "> 10000ng /ml", respectively.

【Limitations of methods】

  1. This kit is only used to detect human plasma/whole blood samples
  2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
  3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
  4. When the concentration of D-dimer in the sample is less than 20000ng/ml, there is no hook effect.
  5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
  6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

【Performance】

1. Analysis sensitivity

No more than 40ng/ml.

2. Accuracy

The relative deviation from the target value is within ±15%.

3. Precision

The within and between assay coefficient of variations are within 15%.

4. Linear range

Within the linear range (40 ~ 10000ng/ml), the linear correlation coefficient R≥0.990.

【Note】

1. This kit is only used for in vitro diagnosis.

2. The test card and sample diluent are disposable and cannot be reused.

3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃~30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.

5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.

 

WWHS Assay list          
Cardiac          
cat#. Product item Specimen Reaction Time Measure Range Clinical Range Itended Use
1 cTnI WB/Serum/Plasma 12min. 0.1-40ng/ml <0.3ng/ml several heart diseases including myocardial infarction and heart failure.
2 Myo WB/Serum/Plasma 12min. 5-400ng/ml <58ng/ml acute myocardial infarction (AMI) in early stage.
3 CK-MB WB/Serum/Plasma 12min. 1-200ng/ml <5ng/ml acute myocardial infarction (AMI) in early stage.
4 NT-proBNP WB/Serum/Plasma 10min. 20-35000pg/ml Under 75:0~347pg/mL,
Over 75:0~449pg/mL
heart failure .
5 D-Dimer WB/Plasma 10min. 40-10000ng/ml <500ng/ml disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
6 cTnI+Myo+CKMB WB/Serum/Plasma 12min. same with single item same with single item Triple marker of myocardial infarction.
7 ST2 WB/Serum/Plasma 10min. 10-400ng/ml <35ng/ml heart failure .
8 Lp-PLA2 WB/Serum/Plasma 10min. 10-900ng/ml <175ng/ml Risk evaluation of ACS and atherosclerotic ischemic stroke patients.
9 S100-β WB/Serum/Plasma 10min. 0.05-10ng/ml <0.2ng/ml Cerebral infarction, cerebral injury.

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2016

  • Total Annual:

    3000-5000

  • Employee Number:

    50~80

  • Ecer Certification:

    Site Member

As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...

+ Read More

Get in touch with us

  • Reach Us
  • WWHS Biotech.Inc(exclusive marketed by Dawin)
  • Rm 505, 1st Building, Shenzhen Biomedicine Innovation Industrial Park, No. 14th, Jinhui Road, East Jinxiu Road, Kengzi Street, Pingshan District, Shenzhen
  • https://www.fiapoct.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!