Packaging Details Common package or custom package
Measuring Range 0~14pH
Resolution 0.01pH
Accuracy ±0.1pH
Working Temperature 0~65℃
Working Pressure <0.2MPa
Temperature Compensation Auto temperature compensation (NTC)
Brand Name kacise
Model Number KPH601
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 100
Delivery Time 3-10days Packaging Details Common package or custom package
Measuring Range 0~14pH Resolution 0.01pH
Accuracy ±0.1pH Working Temperature 0~65℃
Working Pressure <0.2MPa Temperature Compensation Auto temperature compensation (NTC)
Brand Name kacise Model Number KPH601
Certification CE Place of Origin CHINA
High Light Differential Amplifier PH Sensor OnlineDual High Impedance Online PH Meter

KPH601 Online PH Sensor Signal Output: RS-485 (Modbus/RTU Protocol) 

1.Industrial pH measurement

 

A retractable housing has great advantages when installed literally in a pipe-line. The pH electrode may be checked, cleaned, calibrated and

replaced without interrupting the process. When installed in a pipe-line, no bypass valves are necessary. The possibility of withdrawing the

electrode during the process helps to ensure a correct pH measurement. Retractable pH housings meet the requirements for an automatic

pH measuring system. Probes without a retractable function enable the maintenance of an electrode only in combination with an interruption of

the process, emptying of the vessel, etc. in pressurized systems.After having clarified the installation possibilities, the process determines the choice of suitable electrode and housing. Both components of the pH electrode assembly should suit the process requirements.

Electrodes with a liquid electrolyte must be operated with an overpressure, preventing the measuring solution from entering into the

reference electrolyte. The overpressure also ensures a constant cleaning of the junction. Housings for liquid electrolyte electrodes

therefore posses a pressure chamber and a pressure indicator. Using this type of pH electrode assembly requires

control of the overpressure and the periodic inspection of the level of the reference electrolyte. Because of their ability to be refilled, liquid

filled electrodes have a long life expectancy if maintained correctly.Also, in the case of difficult measurements a special electrolyte may be used.

 

Electrodes with gel or polymer electrolytes require very little maintenance. Checking the overpressure and the electrolyte level is not necessary. Polymer electrolyte electrodes are pressure resistant and do not need a classical junction due to their special construction; therefore, they are less sensitive to contamination. Electrodes with a gel electrolyte may be supplied with an overpressure. Since their life expectancy is generally good, a gel or polymer electrode is often the most economical alternative due to their low maintenance costs. In addition, the probe can be kept small and simple, since no pressure chamber is needed. The probe in the probe housing has to have the same corrosion resistance as the reactor. In addition to stainless steel, alloyed materials (e.g. Hastelloy) and plastics (e.g. PVDF) are used.

2.Signal processing and environmental influences

The combination electrode provides a potential which is specific for the pH value. This signal has a high resistance. In order to represent it as a pH value, a special transmitter is needed. The potential of the pH electrode is also influenced by the temperature. Therefore, the pH transmitter offers the possibility of manual or automatic temperature compensation.

3.Technical Specifications

Model KPH601
Measuring Range 0~14pH
Resolution 0.01pH
Accuracy ±0.1pH
Working Temperature 0~65℃
Working Pressure <0.2MPa
Temperature Compensation Auto temperature compensation (NTC)
Power Supply 12~24VDC ±10%
Signal Output RS-485(Modbus/RTU)
Wetted Material POM
Mounting Method Immersion mounting, 3/4 NPT thread
Cable Length 5 meters, other lengths can be customized
Calibration Two-point calibration
Power Consumption <0.3W@12V
Protection Grade IP68
 

4.Dimensional Drawing

Note:The sensor connector is M16-5 core waterproof joint male head.

5.Installation

 

Note: The sensor should not be installed upside down or horizontally when installed, at least at an angle of 15 degrees or more.

Contact Us

Website www.kacise.com

Phone +86-17719566736

Email sales@kacise.com

Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement