China 100kHz 24V PVDF IP68 Ultrasonic Transducer Sensor
China 100kHz 24V PVDF IP68 Ultrasonic Transducer Sensor

  1. China 100kHz 24V PVDF IP68 Ultrasonic Transducer Sensor
  2. China 100kHz 24V PVDF IP68 Ultrasonic Transducer Sensor

100kHz 24V PVDF IP68 Ultrasonic Transducer Sensor

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 1000 Pieces per Week
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Product Ultrasonic Distance Sensor
Detection Range 300mm~3000mm
Transducer frequency approx. 100kHz
Output RS485 + 4-20mA/0-10V
Input power 24V
IP grade IP68
Brand Name Kacise
Model Number KUS series
Place of Origin China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram Supply Ability 1000 Pieces per Week
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Product Ultrasonic Distance Sensor Detection Range 300mm~3000mm
Transducer frequency approx. 100kHz Output RS485 + 4-20mA/0-10V
Input power 24V IP grade IP68
Brand Name Kacise Model Number KUS series
Place of Origin China (Mainland)
High Light IP68 Ultrasonic Transducer SensorPVDF Ultrasonic Transducer Sensor24V Ultrasonic Level Transducer

24V Input Low Power Comsumption RS485 Output PVDF Material IP68 Protection High Presicion Ultrasonic Level Sensor

1. Parameter

General specifications

 

Model: KUS550
Measuring range

0.25m~3m (5m customizable)KUS550A

0.15m-0.6m(1m customizable)KUS550B;

Blind spot The dead zone of KUS550A is 0 ... 250 mm (within 250mm is unstable working zone, it is not recommended to work in this range); the dead zone of KUS550B is 0-150mm;
Supply voltage 3.3 ... 30 VDC, ripple 10 %SS
Working current ≤ 45 mA (fastest measurement speed), typical power consumption ≤ 10 mA;

 

Output signal

0-10V. 0-3V 0-5V /4-20mA/NPN/PNP/RS485 Analog output.
Measurement accuracy ≤1 %F.S.
Temperature compensation Yes
Ranging resolution 0.1mm;

 

Working conditions

Working temperature -40…85℃(233...358K)
Storage temperature -40…85℃(233...358K)

Other instructions

Electrical connection 5-core cable (analog output), 6-core cable (switch output);
Protection class IP67
shell material PVC /PVDF/PTFE/ABS


2. Description of Sensor Functions

Adjusting the analogue output.
The analogue output can be programed as the user want. Such as working at switch output or working at liner output all the parameters can be set by the RS485 interface.
There is 8 types of output functions can be programed.
All the setting routine as follows,
step 1 set one pointed distance by the RS485,
step 2 set another pointed distance by the RS485.
Step3 set the output type liner or switch, and set the related output options
Step4 reboot the sensor.

1. Window mode normally-open and liner mode positive slope output function.

2. Window mode normally-closed and liner mode negative slope output function.

3. Single switching point, normally-open function.

4. Single switching point, normally-closed function.

5. Single switch point with hysteresis gap normally-open function.

6. Single switch point with hysteresis gap normally-closed function.

7. Detection of object presence-normal open function.

8. Detection of object presence-closed open function.

Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only setting the request distance after power restart.
For the RS485 output type.
There is 2 kinds of working style,
One for auto measure, the sensor will measure the distance or level repeatedly, and the measurement period can be set by the UART. The measure result can be fetched every time.
The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU.
For example the measure result can be read by access the register 0x101 by Modbus protocol.
For more information please contact us for the software engineering guide.

3. Dimensions

4. Electronic interface and signals definition

 

5. Installation conditions
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement