China factories

China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China KPH310 Online IP68 Double High Impedance Immersion Mounting RS-485 Signal Output
China KPH310 Online IP68 Double High Impedance Immersion Mounting RS-485 Signal Output

  1. China KPH310 Online IP68 Double High Impedance Immersion Mounting RS-485 Signal Output
  2. China KPH310 Online IP68 Double High Impedance Immersion Mounting RS-485 Signal Output

KPH310 Online IP68 Double High Impedance Immersion Mounting RS-485 Signal Output

  1. MOQ: 0-100
  2. Price: $0-$2000
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 100
Delivery Time 3-10days
Packaging Details Common package or custom package
Range Range 0 ~ 14 Ph
Resolution 0.01 ph
Precision ± 0.1 ph
Operating Temperature 0 ~ 65 °C
Working Pressure < 0.2 mpa
Temperature Compensation Automatic temperature compensation (NTC)
Brand Name kacise
Model Number KPH310
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 100
Delivery Time 3-10days Packaging Details Common package or custom package
Range Range 0 ~ 14 Ph Resolution 0.01 ph
Precision ± 0.1 ph Operating Temperature 0 ~ 65 °C
Working Pressure < 0.2 mpa Temperature Compensation Automatic temperature compensation (NTC)
Brand Name kacise Model Number KPH310
Certification CE Place of Origin CHINA
High Light Double High Impedance Water Quality SensorSubmerged Online PH Sensor0.2mpa Online PH Sensor

Double High Impedance Online PH Sensor Immersion Mounting

KPH310 Online PH Sensor Signal Output: RS-485 Double High Impedance Differential Amplifier Ip68

1.Application Environment

For environmental water quality monitoring, acid/alkali/salt solution, chemical reaction process, industrial production process, can meet the majority of industrial applications online pH measurement requirements.

2.Feature

  • Signal Output: RS-485(Modbus/RTU protocol).
  • Convenient to connect to PLC, DCS, Industrial Control Computer, General Controller, paperless recording instrument or touch screen, and other third-party equipment.
  • Double high impedance Differential amplifier, strong anti-interference, fast response.
  • The patented pH probe, with an internal reference fluid at a pressure of at least 100 kpa (1 bar), oozes extremely slowly from the microporous salt bridge, with a forward exudation lasting more than 20 months. Such a reference system is very stable, electrode life than ordinary industrial electrode times longer.
  • Easy to install: submerged installation.
  • Ip68, protection level.

3.Technical Specifications

Model Number KPH310
Range Range 0 ~ 14 Ph
Resolution 0.01 ph
Precision ± 0.1 ph
Operating Temperature 0 ~ 65 °C
Working Pressure < 0.2 mpa
Temperature Compensation Automatic temperature compensation (NTC)
Power Supply 12 ~ 24 VDC ± 10%
Signal Output RS-485(Modbus/RTU)
Contact Material Pom
Installation Mode Immersion mounting
Cable Length 5 meters, another length can be customized
Calibration Mode Two-point calibration
Power Consumption < 0.05 W
Protection Level IP68
 

wiring

Red ----------power supply

Black---------Power Ground

Blue----------RS485A+

Green--------RS485B-

 

 

4.Dimensional Drawing

 

Tips: Q&A

48.What is in the aqueous process that will challenge the pH electrode?

For example:

What is the maximum temperature of the water?

 

Extremely high temperatures may damage the materials of the pH sensor. the reasonable temperature range is 0℃-65℃

Are you measuring pure water or is there any hydrofluoric acid present within the process?

 

Standard pH sensors will not perform for the long term in these types of environments and will lead to inaccurate pH measurements. For these process environments, Kacise has specially designed versions of our industrial pH sensors for low conductivity (-LC) or applications where hydrofluoric acid (-HF) is present.

 

49.Are there any known ground loop issues?

With process pH sensors, a ground loop is an unwanted electrical current path, in the system, where stray signals cause interference in the pH measurement. If this is a recognized issue, you will want to use a pH sensor that has a solution ground electrode to handle this stray voltage in the process system. The Kacise 310 pH sensor has this as a popular measurement option.

 

50.What is your preferred price point for a process pH sensor?

This is always the golden question, but is also important to consider the value in different styles of pH sensors while making your decision.

 

To assist with weighing features and value versus price, Kacise has developed a tiered offering based off of application needs that will benefit you while making the best choice when considering industrial process pH sensors.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement