China Anti Interference Turbidity Water Quality Sensor Scattering Method
China Anti Interference Turbidity Water Quality Sensor Scattering Method

  1. China Anti Interference Turbidity Water Quality Sensor Scattering Method
  2. China Anti Interference Turbidity Water Quality Sensor Scattering Method

Anti Interference Turbidity Water Quality Sensor Scattering Method

  1. MOQ: 0-100
  2. Price: $0-$2000
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 100
Delivery Time 3-10days
Packaging Details Common package or custom package
Measuring principle Scattering method
Range 0 ~ 100 NTU
Resolution 0.1 NTU, 0.1 °C
Precision ± 3% or ± 2 NTU ± 0.5 °C
Calibration mode Two-point calibration
Temperature compensation Automatic temperature compensation (PT1000)
Brand Name kacise
Model Number KTU310
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 100
Delivery Time 3-10days Packaging Details Common package or custom package
Measuring principle Scattering method Range 0 ~ 100 NTU
Resolution 0.1 NTU, 0.1 °C Precision ± 3% or ± 2 NTU ± 0.5 °C
Calibration mode Two-point calibration Temperature compensation Automatic temperature compensation (PT1000)
Brand Name kacise Model Number KTU310
Certification CE Place of Origin CHINA
High Light Anti Interference Water Quality Sensor100NTU Online Turbidity SensorFiber Structure Online Turbidity Sensor

KTU310 Online Turbidity Sensor 90 ° Angle Scattering Principle Fiber Structure, Strong Anti-Interference Ability

 

1.Principle

The KTU310 integrated online turbidimeter is designed and made by the principle of scattering light turbidimeter. When a beam of light enters a water sample, the light is scattered by the turbidity material in the water sample. The turbidity in the water sample can be calculated by measuring the intensity of the scattered light in the vertical direction of the incident light and comparing it with the internal calibration value, the final value is output after linearization.

2.Feature

  • 90 ° angle scattering principle, built-in temperature sensor
  • Support RS-485, Modbus/RTU protocol
  • Fiber structure, the strong anti-interference ability of external light
  • The infrared LED light source, high stability
  • IP68, shield, water depth, 20 meters
  • Convenient, fast, stable, and easy to maintain

3.Technical Specifications

Model number KTU310
Measuring principle Scattering method
Range 0 ~ 100 NTU
Resolution 0.1 NTU, 0.1 °C
Precision

± 3% or ± 2 NTU

± 0.5 °C

Calibration mode Two-point calibration
Temperature compensation Automatic temperature compensation (PT1000)
Output mode RS-485(Modbus/RTU)
Working conditions 0ー50 °C, < 0.2 mpa
Storage temperature - 5 ~ 65 °C
Installation mode Immersion mounting, 3/4 NPT thread
Power consumption < 0.05 W
Power supply 12 ~ 24 VDC ± 10%
Protection level IP68
 

4.Dimensional Drawing

 

Tips: Historical Turbidity Measurement Method


The Jackson Candle Turbidimeter used attenuation to determine turbidity.
The historical method for measuring turbidity was the Jackson Candle Turbidimeter. Developed over a century ago, this instrument was constructed from a candle and a flat-bottomed glass tube. Much like a transparency tube, water is poured down into the tube until the candle flame is no longer distinctly visible 2. The light does not disappear completely, only the image of the flame will. This occurs when the intensity of the transmitted light is equal to the amount of light scattered by particles in the water. The more turbid the water is, the quicker the image of the flame disappears.
The Jackson Candle Turbidimeter was the first practical attempt to quantify turbidity. In addition to the instrument, a standard suspension was developed, allowing the tube to be “calibrated” to the user’s eye 31. While the scale of the turbidimeter was in ppm-silica, units for this instrument were called Jackson Turbidity Units (JTU). After formazin was invented in 1926, it was used as a new calibration standard for this method, and Formazin Turbidity Units (FTU) were adopted 31. However, even with the improvement in standards, this method was limited in scope. The Jackson Candle Turbidimeter could not detect turbidity levels below 25 JTU 2,31. It was also highly subjective as readings were based on human observation. This introduced errors based on personal perception and judgment. Other light-extinction based turbidimeters were developed, but they remained dependent on human eyesight 31. Today, these methods are considered obsolete in favor of turbidity instruments (such as meters and sensors) that offer an increased measurement range and improved accuracy.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement