Payment Terms | L/C, D/A, T/T, D/P, Western Union, MoneyGram |
Supply Ability | 1000 Pieces per Week |
Delivery Time | 5-8 work days |
Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Type | GXEFM2000 |
Application range | Electrically conductive fluids |
Measuring principle | Faraday’s law |
Primary measured value | Flow velocity |
Secondary measured value | Volume flow |
Product | Electromagnetic Flow Meter |
Brand Name | Kacise |
Model Number | GXEFM2000 |
Certification | certificate of explosion-proof, CE |
Place of Origin | China (Mainland) |
View Detail Information
Explore similar products
Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000
Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant
Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC
Flange / Thread Electromagnetic Water Flow Meter With Grounding Rings
Product Specification
Payment Terms | L/C, D/A, T/T, D/P, Western Union, MoneyGram | Supply Ability | 1000 Pieces per Week |
Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Type | GXEFM2000 | Application range | Electrically conductive fluids |
Measuring principle | Faraday’s law | Primary measured value | Flow velocity |
Secondary measured value | Volume flow | Product | Electromagnetic Flow Meter |
Brand Name | Kacise | Model Number | GXEFM2000 |
Certification | certificate of explosion-proof, CE | Place of Origin | China (Mainland) |
High Light | wastewater flow meter ,electromagnetic water flow meter |
Description
1. Simple structures, firm, no movable parts and long operation life.(Guarantee in 1 years)
2. No intercepting fluid parts, no pressure loss and fluid clogging.
3. No mechanical inertia, quick response and good stability, application in automatic examination, adjustment & controlling.
4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.
Parameters
Pipe diameter | DN6~DN2600 | |
Accuracy | 0.3% (Option), 0.5%, 1.0% of F.S.. | |
Repeatability | Below 0.25% | |
Power | AC: 220V, 50-60Hz; DC: +24V(Option) | |
Output Signals | 4~20mA, Pulse, 0~5V | |
Conduit connection | M20 * 1.5 Thread | |
Communication Interface | RS-232; RS-485; HART | |
Operation Pressure | 1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special) | |
Fluid Temperature | -20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material | |
Ambient Temperature | Sensor -40°C ~80°C. transducer -15°C ~50°C | |
Ambient Humidity | ≤ 85%RH (at 20C) | |
Cable Outlet Size | M20×1.5 | |
Power Supply | 220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years) | |
Power Consumption | ≤ 15W | |
Protection Ratings | Remote type: sensor IP68, transducer IP65. | |
Materials | Electrode | 316L (stainless steel), Hastelloy C, Hastelloy B,Titanium, Tantalum, etc. |
Liner | PTFE, Soft rubb er, Hard rubber, F46, FS, PUR. | |
Measuring tube | SS 304, carbon steel | |
Flange | Carbon Steal, SS304 | |
Ground ring | 316L (stainless steel), HC, Ti, Ta, Cu. | |
Connection of Flange | National Standard GB9119-88 (DIN2051, BS4504), JIS,ANSI. Screw. Tri-clamp for sanitary application Insertion type. | |
EX-proof protection | Exde ib ii BT2 | |
Quality control | ISO9001-2008, CE |
Measuring system
Measuring principle | Faraday’s law |
Application range | Electrically conductive fluids |
Measured Value | |
Primary measured value | Flow velocity |
Secondary measured value | Volume flow |
Design
Features | Fully welded maintenance-free sensor |
Flange version with full bore flow tube | |
Standard as well as higher pressure ratings | |
Large diameter range from DN15~3000 with rugged liners approved for drinking water | |
Industry specific insertion lengths | |
Modular construction | The measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version |
Compact version | With 511B converter: 110~240Vac Power |
With 521B converter: 18~36V DC Power | |
With W800L/W800W: Battery Power | |
Remote version | In wall mount version with 211B converter (110~240Vac or 221B converter 18~36V DC |
With W800F converter: Battery Power | |
Measurement range | -12…+12m/s /-40...+40ft/s |
Measuring accuracy
Reference conditions | Flow conditions similar to EN 29104 |
Medium: water | |
Electrical conductivity: ≥300μs/cm | |
Temperature: +10~+30℃/+50~+80℉ |
Inlet setion: ≥5DN | |
Operating pressure: 1Bar/14.5psig | |
Flow Meter Accuracy | Standard: 0.5% of rate |
Optional: 0.2% of rate |
Operating conditions
Temperature | |
Process temperature | Hard rubber liner: -5~+60℃ |
Polypropylene liner: -5~+90℃ | |
PTEF liner: -5~+120℃ | |
Ambient temperature | Standard (with aluminum converter housing) |
-20~+60℃ (Protect electrics against self-heating with ambient temperature above 55℃ | |
Stroage temperature | -20~70℃ |
Pressure | |
EN 1092-1 | DN2200~3000: PN2.5 |
DN1200~2000: PN6 | |
DN200~1000: PN10 | |
DN65~150: PN16 | |
DN10~50: PN40 | |
Other pressure on request | |
ISO insertion length | Optional for DN15~600 |
ASME B16.5 | 1~24”: 150lb RF |
Other pressure on request | |
JIS | DN10~1000/ 2~40”: 10K |
Other pressure on request | |
Pressure drop | Negligible |
Fluid | |
Physical condition | Conductive liquids |
Electrical conductivity | ≥5μs/cm |
Permissible gas content (volume) | ≤5% |
Permissible solid content | ≤70% |
Installation conditions
Installation | Take care that flow sensor is always fully filled |
For detailed information see chapter “Cautions for installation” | |
Flow direction | Forward and reverse |
Arrow on flow sensor indicates positive flow direction | |
Inlet run | ≥5 DN |
Outlet run | ≥2 DN |
Process connection
Flange | |
EN1092-1 | DN25~3000 in PN6~40 |
ASME | 1~120” in 150 lb RF |
JIS | 25~1000 in 10~20k |
Design of gasket surface | RF |
Other sizes or pressure ratings on request |
Company Information
Xi'an Kacise is qualified with ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof certificates, etc. which ensure that our products comply with international standards.
We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. Based on experienced technical and management personnel, through efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.
Currently, Kacise sensors have already been exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regard “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!