China FT-NIR Analyzer with 900-2500 nm Wavelength Range 0.005 cm⁻¹ Wavenumber Accuracy
China FT-NIR Analyzer with 900-2500 nm Wavelength Range 0.005 cm⁻¹ Wavenumber Accuracy

  1. China FT-NIR Analyzer with 900-2500 nm Wavelength Range 0.005 cm⁻¹ Wavenumber Accuracy

FT-NIR Analyzer with 900-2500 nm Wavelength Range 0.005 cm⁻¹ Wavenumber Accuracy

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Principle Fourier - transform Near Infrared analyzer via fiber - optic probe or single path
Wavelength range 900 - 2500 nm
Wavenumber accuracy 0.005 cm⁻¹
Wavenumber resolution 0.007 cm⁻¹
No. of channel 4, 8, 16, 32, 64 cm⁻¹ selectable
Measurement time 4 seconds as minimum (depending on the number of averaging and measuring channels, as well as measurement channels)
Model Number NR800
Brand Name Yokogawa

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Principle Fourier - transform Near Infrared analyzer via fiber - optic probe or single path Wavelength range 900 - 2500 nm
Wavenumber accuracy 0.005 cm⁻¹ Wavenumber resolution 0.007 cm⁻¹
No. of channel 4, 8, 16, 32, 64 cm⁻¹ selectable Measurement time 4 seconds as minimum (depending on the number of averaging and measuring channels, as well as measurement channels)
Model Number NR800 Brand Name Yokogawa
High Light 900-2500 nm wavelength range FT-NIR Analyzer0.005 cm⁻¹ wavenumber accuracy FT-NIR Analyzer0.007 cm⁻¹ wavenumber resolution FT-NIR Analyzer

InfraSpec NR800 is a  FT-NIR analyzer offering unparalleled reliability and stability for a wide range of process and laboratory applications from Yokogawa. Its high wavelength resolution, outstanding accuracy and wide scanning range deliver a new level of process information, opening up new possibilities. Direct transfer of a calibration model from the laboratory to the process, or among processes, is also possible. And of course, ease of operation and user-friendly software are key design concepts of the NR800.

The NR800 FT-NIR from Yokogawa is based on over 50 years of R&D in analyzer systems especially spectrometers and sensing devices, and application experience gained as the leading supplier of process measurement and control systems.


Analyzer - Item Description
Principle Fourier - transform Near Infrared analyzer via fiber - optic probe or single path
Wavelength range 900 - 2500 nm
Wavenumber accuracy 0.005 cm⁻¹
Wavenumber resolution 0.007 cm⁻¹
No. of channel 4, 8, 16, 32, 64 cm⁻¹ selectable
No. of measurement Max 12 channels (Max 64 optical multiplexers)
Max 4 channels with no optical analyzer
Measurement time 4 seconds as minimum (depending on the number of averaging and measuring channels, as well as measurement channels)
No. of cutter detection items Max 12 per channel (Max 48 per analyzer)
Chemometrics software VERSOR DIRRECT™
Communication interface RS422 Modbus; 2 channels (DCS, IO unit)
Ethernet: 1 channel (Engineering PC)
Contact output System alarm; 1 (Annunciator; 1
(Explosion - proof model)
Power fail; 1, System alarm; 1
(Non - explosion - proof model)
Contact Input Stream identification: 8
Measurement enable: 4
Enclosure General purpose
Model N8607G: FM approved.
Type X - purging and explosion - proof for Class I, Div1, Group B, C, D, T5.
Temperate Class II, III, and
Type N8608G: TIS certified.
Suitable for TIS Ex IIB T5 and
Temperature Class T5.
Suitable for ATEX Ex II 2G Ex tb
consumption: Approx. 250 VA.
Power supply Class 1 Laser Product (IEC 60825 - 1:2014, GB/T 7247.1 - 2020)
Classification of laser product -10 to 40 °C, 0 to 95% RH
Environment temp., RH General - purpose model: Approx. 50 kg
Explosion - proof model: Approx. 85 kg
Weight Please refer to GS12V04303 - 01E in detail.


Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement