Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability | 1000 Piece/Pieces per Week negotiable |
Delivery Time | 5-8 work days |
Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Measuring object | Concentration of mixed liquid suspended solid (MLSS) in an aeration tank in a sewage or industrial wastewater treatment plant |
Measuring principle | Scattered/transmitted light comparison method |
Measuring range | 500 to 20000 mg/l |
Temperature of measured object | 0 to 50℃ |
Brand Name | Yokogawa |
Model Number | SS400G, SS300G |
View Detail Information
Explore similar products
Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
Product Specification
Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Measuring object | Concentration of mixed liquid suspended solid (MLSS) in an aeration tank in a sewage or industrial wastewater treatment plant | Measuring principle | Scattered/transmitted light comparison method |
Measuring range | 500 to 20000 mg/l | Temperature of measured object | 0 to 50℃ |
Brand Name | Yokogawa | Model Number | SS400G, SS300G |
High Light | 500-20000 mg/l MLSS Analyzer ,Scattered/Transmitted Light Comparison MLSS Sensor ,Self-Cleaning Water Quality Sensor |
The SS400 MLSS analyzer is a measuring system best suited to continuously and consistently measure the concentration of mixed liquor suspended solids (MLSS) in an activated-sludge treatment process found in sewage or industrial wastewater treatment facilities.
The SS400G MLSS converter has a measuring range as wide as 500-20000 mg/l (ppm). Microprocessor-based, it has a wealth of self-diagnostic functions and alarm contact outputs like other converters in the EXA series, as well as excellent operability.
The SS300G MLSS sensor uses a measuring method that compares transmitted light with scattered light. The sensor is designed with due care to the arrangement of the optical system. These design features enable measurement of even low concentrations, making the sensor less susceptible to disturbing light. The optional jet cleaning unit permits continuous and consistent measurement even in an application where the sensor is exposed to contaminants.
A self-cleaning floating holder is available in addition to free-standing and immersion models, offering a wide range of choices according to the application needs.
Converter
Sensor
Measuring object | Concentration of mixed liquor suspended solids (MLSS) in an aeration tank in a sewage or industrial wastewater treatment plant |
Measuring method | Transmitted/scattered light comparison method |
Measuring range | 500 to 20000 mg/l |
Output signal | Two outputs, 4 to 20 mA DC; maximum load resistance: 600 Ω |
Output range | Minimum 0 to 1000 mg/l Maximum 0 to 20000 mg/l |
Contact output | Four outputs |
Contact input | Voltage-free contact for remote range selection and start of cleaning |
Ambient temperature | -10 to 55℃ |
Relative humidity | 10 to 90% RH (non-condensing) |
Construction | Complies with JIS C0920 watertight, IEC IP65 and NEMA 4X standards |
Supply voltage | 100 to 240 V AC, 50/60 Hz, 24 V DC |
Power consumption | 22 VA maximum (AC power) 5 W maximum (DC power) |
Weight | Approx. 2.5 kg |
Shape | Probe-like Sensor |
Measuring object | Concentration of mixed liquid suspended solid (MLSS) in an aeration tank in a sewage or industrial wastewater treatment plant |
Measuring principle | Scattered/transmitted light comparison method |
Measuring range | 500 to 20000 mg/l |
Temperature of measured object | 0 to 50℃ |
Pressure of measured object | 0 to 200 kPa |
Flow velocity | 1 m/sec maximum |
Cable length | 3, 5, 10, 15 or 20 m |
Material of wetted part or junction | Body; Stainless steel (304SS or equivalent) Window; glass O-ring; nitrile rubber Cable; PVC |
Weight | Approx. 0.5 kg plus N x 0.12 kg, where N is cable length |
Cleaning unit (optional) | Jet cleaning Note: No cleaning unit can be used if the sensor is equipped with a floating ball holder. |
Material of wiper cleaning unit | Nitrile rubber and 304SS (wetted part) |
Material of jet cleaning unit | Polypropylene, polyethylene and 304SS (wetted part) |
Ambient temperature | -10 to 50℃ |
Construction | Complies with JIS rainproof standard |
Linearity | ±4.5 % F.S. (by stable kaolin) |
Repeatability | 2 % F.S. (by stable kaolin) |
Stability | Zero: ±2 % F.S./day (by city water) Span: ±2 % F.S./day (by calibration kit) |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us