China Explosion - Proof Infrared Gas Analyzer KGD - MQ - 510 For Industrial Site
China Explosion - Proof Infrared Gas Analyzer KGD - MQ - 510 For Industrial Site

  1. China Explosion - Proof Infrared Gas Analyzer KGD - MQ - 510 For Industrial Site

Explosion - Proof Infrared Gas Analyzer KGD - MQ - 510 For Industrial Site

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO, CO₂, CH₄, C₃H₈, O₂, H₂S
Measurement Principle NDIR, ECD
Measurement Range CO/CO₂/CH₄/C₃H₈: (0 - 100)%; O₂: (0 - 25)%; H₂S: (0 - 9999) ppm
Linearity Error CO/CO₂/CH₄/C₃H₈: ±1%F.S.; O₂/H₂S: ±2%F.S.
Brand Name KACISE
Model Number KGD-MQ-510
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO, CO₂, CH₄, C₃H₈, O₂, H₂S Measurement Principle NDIR, ECD
Measurement Range CO/CO₂/CH₄/C₃H₈: (0 - 100)%; O₂: (0 - 25)%; H₂S: (0 - 9999) ppm Linearity Error CO/CO₂/CH₄/C₃H₈: ±1%F.S.; O₂/H₂S: ±2%F.S.
Brand Name KACISE Model Number KGD-MQ-510
Certification CE Place of Origin CHINA
High Light Industrial Site Safety Infrared Gas AnalyzerExplosion - Proof Infrared Gas AnalyzerInfrared Gas Analyzer KGD - MQ - 510

Explosion - proof Infrared Gas Analyzer KGD - MQ - 510 for Industrial Site Safety

Product Introduction

The Explosion - proof Infrared Gas Analyzer KGD - MQ - 510 adopts non - dispersive infrared (NDIR) gas analysis technology and long - life electrochemical sensing technology with independent intellectual property rights. It can simultaneously measure the volume concentrations of gases such as CO, CO₂, CH₄, C₃H₈, O₂, and H₂S on - line. The instrument is equipped with pre - treatment components, which can solve applications in harsh working conditions with moisture and dust on - site. Its explosion - proof design can meet the gas monitoring needs of flammable and explosive places in multiple fields, ensuring the safety of industrial sites.

Product Features

  • Explosion - proof Design: The instrument adopts an explosion - proof design. The flame - proof enclosure separates the internal space of the equipment from the surrounding environment. It ensures that when an explosion occurs, the enclosure can withstand the explosion pressure without being damaged, and prevents the flame from passing through the flame - proof gap to ignite the external explosive environment.
  • High Measurement Accuracy: There is no cross - interference among multi - component measured gases, resulting in high measurement accuracy. It has a self - diagnosis function, enabling on - line inspection of sensor status.
  • Stable Working Performance: The sensor adopts a dual - channel design, which is highly stable. All parts in contact with the sample gas are made of special heat - resistant and corrosion - resistant materials such as stainless steel and polytetrafluoroethylene.
  • High Degree of Automation: It is equipped with a professional pre - treatment solution, featuring high automation and low maintenance. Real - time on - line monitoring can be achieved without manual on - site operation, greatly reducing the labor cost of enterprises.
  • Simple Data Management: Data can be transmitted to the superior centralized control system through multiple interfaces.

Technical Parameters

Items Details
Measured Components CO, CO₂, CH₄, C₃H₈, O₂, H₂S
Measurement Principle NDIR, ECD
Measurement Range CO/CO₂/CH₄/C₃H₈: (0 - 100)%; O₂: (0 - 25)%; H₂S: (0 - 9999) ppm
Linearity Error CO/CO₂/CH₄/C₃H₈: ±1%F.S.; O₂/H₂S: ±2%F.S.
Resolution 0.01% (For low - range, the resolution can reach 1ppm)
Repeatability ≤ 2%
Response Time T90 ≤ 15s (NDIR)
Optimal Flow Rate (0.7 - 1.2) L/min
Inlet Pressure (2 - 50) kPa
Gas Requirements Dust - free, water - free, oil - free
Electrical Parameters  
Communication RS - 485/RS - 232; 4 - 20mA; Ethernet
Power Supply AC220V, 50Hz
Display LCD Display
Explosion - proof Grade Certification Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db
Functional Configuration Built - in zero - adjustment air pump for automatic air zero - adjustment; self - diagnosis function available for on - line inspection of sensor status

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement