China KGD MQ 531 Biogas Analyzer Smart Portable Type Bluetooth 4.0 Communication and
China KGD MQ 531 Biogas Analyzer Smart Portable Type Bluetooth 4.0 Communication and

  1. China KGD MQ 531 Biogas Analyzer Smart Portable Type Bluetooth 4.0 Communication and

KGD MQ 531 Biogas Analyzer Smart Portable Type Bluetooth 4.0 Communication and

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CH4/CO2/H2S/O2 /H2/CO
Measurement Principle CH4/CO2: NDIR; H2S/O2: ECD
Measurement Range CH4: (0 - 100)%; CO2: (0 - 50)%; H2S: (0 - 9999) ppm; O2: 0 - 25% (All ranges are optional)
Linear Error CH4 /CO2: ±2%F.S., O2/H2S: ±3%F.S.
Electrical Parameters Electrical parameters
Communication USB interface, Bluetooth 4.0
Brand Name KACISE
Model Number KGD-MQ-531
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CH4/CO2/H2S/O2 /H2/CO Measurement Principle CH4/CO2: NDIR; H2S/O2: ECD
Measurement Range CH4: (0 - 100)%; CO2: (0 - 50)%; H2S: (0 - 9999) ppm; O2: 0 - 25% (All ranges are optional) Linear Error CH4 /CO2: ±2%F.S., O2/H2S: ±3%F.S.
Electrical Parameters Electrical parameters Communication USB interface, Bluetooth 4.0
Brand Name KACISE Model Number KGD-MQ-531
Certification CE Place of Origin CHINA
High Light Biogas Analyzer Smart Portable TypeElectrical Parameters Biogas AnalyzerBluetooth 4.0 Biogas Analyzer

KGD - MQ - 531 Biogas Analyzer (Smart Portable Type)

Product Introduction

The KGD - MQ - 531 Biogas Analyzer (Smart Portable Type) features a portable design. It adopts non - dispersive infrared gas analysis technology with independent intellectual property rights and long - life electrochemical sensing technology. It can simultaneously measure the volume concentrations of gases such as CH4, CO2, H2S, and O2 in biogas components online. While inheriting the advantages of the previous - generation product such as high accuracy and no consumables, its volume has been reduced by 75% and its weight by 60%, making it outstandingly compact and more convenient to carry.

Product Features

  • Portable Body Design: Easy to carry, it can meet the needs of both on - site industrial measurement and laboratory air - bag sampling analysis.
  • High Measurement Accuracy: With a modular sensor design, it can simultaneously measure the volume concentrations of gases such as CH4, CO2, H2S, and O2 in biogas components online. CO and H2 sensors can be extended, and there is no cross - interference among multi - component measured gases.
  • Stable Working Performance: The sensor adopts a dual - channel design, which is highly stable. It has a self - diagnosis function and can check the sensor status online.
  • Intelligent Battery Management: Equipped with a soft - start power switch and intelligent battery management to prevent the instrument from operating under low - battery conditions.
  • Simple Data Management: Automatically stores measurement data, with query and deletion functions. Data can be transmitted to the superior centralized control system through multiple interfaces.
  • Low Cost of Use: Compared with gas analysis technologies such as Orsat and chromatography, the measurement process does not require disassembly and installation, nor does it consume chemical reagents. It is simple to operate and has no consumables.
  • Can collect gas flow rate (requires a handheld flow meter to be configured).
  • Has a Bluetooth function, enabling the uploaded collection data to be displayed on the APP.

Technical Parameters

Parameter Details
Measured Components CH4/CO2/H2S/O2 /H2/CO
Measurement Principle CH4/CO2: NDIR; H2S/O2: ECD
Measurement Range CH4: (0 - 100)%; CO2: (0 - 50)%; H2S: (0 - 9999) ppm; O2: 0 - 25% (All ranges are optional)
Linear Error CH4 /CO2: ±2%F.S., O2/H2S: ±3%F.S.
Electrical Parameters Electrical parameters
Communication USB interface, Bluetooth 4.0
Power Supply Built - in 18650 rechargeable lithium - ion battery (replaceable), external 5V/2A charger
Display Color LCD display

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement