China KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites
China KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites

  1. China KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites

KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO, CO₂, O₂, Flue Gas Temperature; SO₂, NO, NO₂ sensors can be extended
Measurement Principle O₂: ECD; CO/CO₂: NDIR; Flue Gas Temperature: K - type thermocouple or S - type thermocouple
Measurement Range O₂: (0 - 21)%; CO: (0 - 5000) ppm; CO₂: (0 - 25)%; Flue Gas Temperature: (0 - 800)/(0 - 1200)℃
Linear Error CO/CO₂: ±1%F.S.; O₂: ±2%F.S.; Flue Gas Temperature: ±3℃; or ±1% of measured value
Resolution O₂: 0.01%; CO: 1ppm; CO₂: 0.01%; Flue Gas Temperature: 0.1℃
Repeatability ≤ 2%
Brand Name KACISE
Model Number KGD-MQ-514
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO, CO₂, O₂, Flue Gas Temperature; SO₂, NO, NO₂ sensors can be extended Measurement Principle O₂: ECD; CO/CO₂: NDIR; Flue Gas Temperature: K - type thermocouple or S - type thermocouple
Measurement Range O₂: (0 - 21)%; CO: (0 - 5000) ppm; CO₂: (0 - 25)%; Flue Gas Temperature: (0 - 800)/(0 - 1200)℃ Linear Error CO/CO₂: ±1%F.S.; O₂: ±2%F.S.; Flue Gas Temperature: ±3℃; or ±1% of measured value
Resolution O₂: 0.01%; CO: 1ppm; CO₂: 0.01%; Flue Gas Temperature: 0.1℃ Repeatability ≤ 2%
Brand Name KACISE Model Number KGD-MQ-514
Certification CE Place of Origin CHINA
High Light Industrial Sites Combustion Efficiency AnalyzerKGD Combustion Efficiency Analyzer

KGD - MQ - 514 Combustion Efficiency Analyzer for Industrial Sites

Product Introduction

The KGD - MQ - 514 Combustion Efficiency Analyzer adopts non - dispersive infrared (NDIR) gas analysis technology with independent intellectual property rights and long - life electrochemical sensing technology. It can simultaneously measure the volume concentrations of gases such as CO, CO₂, and O₂, as well as the flue gas temperature, and calculate the excess air coefficient, providing a basis for adjusting the combustion conditions in industrial sites.

Product Features

  • Simultaneously measures flue gas components and temperature: It can simultaneously measure the volume concentrations of gases such as CO, CO₂, and O₂ in the flue gas, and automatically calculate and display the flue gas temperature and the excess air coefficient.
  • High measurement accuracy: It has a wide measurement range. The sensor will not be damaged due to over - range, and it has a long service life and high accuracy.
  • Portable body design: Equipped with an integrated imported sampling gun, it is easy to carry and can meet the needs of both on - site industrial measurement and laboratory airbag sampling analysis.
  • Intelligent power management: It is equipped with a soft - start power switch to prevent the instrument from operating under low - power conditions.
  • Simple data management: It automatically stores measurement data, has query and deletion functions, and can transmit data to the superior centralized control system through multiple interfaces.

Technical Parameters

Measured Components CO, CO₂, O₂, Flue Gas Temperature; SO₂, NO, NO₂ sensors can be extended
Measurement Principle O₂: ECD; CO/CO₂: NDIR; Flue Gas Temperature: K - type thermocouple or S - type thermocouple
Measurement Range O₂: (0 - 21)%; CO: (0 - 5000) ppm; CO₂: (0 - 25)%; Flue Gas Temperature: (0 - 800)/(0 - 1200)℃
Linear Error CO/CO₂: ±1%F.S.; O₂: ±2%F.S.; Flue Gas Temperature: ±3℃; or ±1% of measured value
Resolution O₂: 0.01%; CO: 1ppm; CO₂: 0.01%; Flue Gas Temperature: 0.1℃
Repeatability ≤ 2%
Operating Temperature (0 - 50)℃
Relative Humidity (5 - 85)%
Response Time T90 < 15s (NDIR)
Electrical Parameters Electrical Parameters
Communication RS - 232/RS - 485
Battery Power Supply Powered by built - in rechargeable lithium - ion battery, with an external 12.6V charger, can work continuously for more than 10 hours
AC Power Supply 100 - 240VAC, 80W
Display LCD Display
Functional Configuration Built - in imported sampling air pump, anti - pressure capacity 200hPa
Self - diagnosis function available for on - line inspection of sensor status
Optional pretreatment device

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement