China Absolute And Gauge Pressure Cerabar PMC51
China Absolute And Gauge Pressure Cerabar PMC51

  1. China Absolute And Gauge Pressure Cerabar PMC51
  2. China Absolute And Gauge Pressure Cerabar PMC51
  3. China Absolute And Gauge Pressure Cerabar PMC51

Absolute And Gauge Pressure Cerabar PMC51

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Accuracy Standard 0.1%
Process temperature -20°C...130°C(-4°F...266°F)
Pressure measuring range 100 mbar...40 bar(1.5psi...600psi)
Process pressure / max. overpressure limit 60 bar (900 psi)
Main wetted parts Ceraphire
Max. measurement distance 400 m (1312 ft) H2O
Model Number Cerabar PMC51
Certification CE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Accuracy Standard 0.1% Process temperature -20°C...130°C(-4°F...266°F)
Pressure measuring range 100 mbar...40 bar(1.5psi...600psi) Process pressure / max. overpressure limit 60 bar (900 psi)
Main wetted parts Ceraphire Max. measurement distance 400 m (1312 ft) H2O
Model Number Cerabar PMC51 Certification CE
High Light Gauge Cerabar PMC51Absolute Cerabar PMC51

Absolute and gauge pressure Cerabar PMC51

 

Field of application

The Cerabar PMC51 digital pressure transmitter with capacitive, oil-free ceramic measuring cell is typically used in process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 / IEC 61511.

 

Single chamber aluminum or stainless steel (316L) housing.

Process connections: Threads, flanges or hygienic connections

Process temperature: -40 to 130°C (-40 to 266°F), 150°C (302°F) for 1h

Measuring ranges: -1/0 up to 40bar (-15/0 to 600psi)

Accuracy: ±0.1%, "Platinum" ±0.075%

International explosion protection certificates, SIL, hygienic approvals, marine approvals

 

Benefits

  • Best fit for vacuum applications and applications with corrosive and abrasive media
  • Process safety through membrane breakage detection
  • Overload-resistant high purity ceramic sensor (99.9% Al2O3)
  • Condensation resistant also for hygienic applications
  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
  • Process pressure up to SIL2, certified to IEC 61508 and IEC 61511
  • Available with mounted manifolds: always fit, always tested for leaks

Product Description

Measuring principle Absolute and gauge pressure
Characteristic Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire)
Supply voltage 4...20 mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy Standard 0.1%
Platinum 0.075%
Long term stability
0.2% of URL/ year
0.4% of URL/ 5 years
0.5% of URL/ 10 years
Process temperature -40°C...+130°C(-40°F...+266°F)+150°C for 1h(+302°F for 1h)
Ambient temperature -40°C...+85°C(-40°F...+185°F)
Measuring cell 100 mbar...40 bar(1.5 psi...600 psi)
relative/ absolute
Smallest calibratable span 10 mbar (0.15 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 20:1
Max. overpressure limit 60 bar (900 psi)
Process connection Thread:
G1/2...G2, R1/2, MNPT1/2
Flange:
DN25...DN80,
ASME 1"...4",
JIS 10K
Process connection hygienic Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD
Material process membrane Ceramic
Material gasket Viton, EPDM, NBR, Kalrez
Fill fluid None, dry measuring cell
Material housing Die-cast aluminum,
AISI 316L
Communication 4...20 mA
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN10204-3.1
NACE MR0175
Hygienic approvals CoC ASME-BPE
3A, EHEDG
Marine approvals GL/ ABS/ LR/ BV/ DNV
Drinking water approvals NSF
Successor PMC51B

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement