Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
ConsentDo not consent
Wuhan Huaying Electric Power Tech & Science Co., Ltd
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Automatic Three Phase Power Transformer Turn Ratio and Vector Group Tester","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/20\/af\/d63792624ae8fb9518d0cc351bc1-200x200-1\/automatic_three_phase_power_transformer_turn_ratio_and_vector_group_tester.jpg","attrs":{"Place of Origin":"Wuhan Hubei China","Brand Name":"Huaying","Certification":"ISO","Model Number":"HYBC-901"}}
{"title":"Power Transformer No Load \/ Load Testing Equipment With Wide Voltage Range","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/3c\/33\/94231a2b1ce717842d1974bd2679-200x200-1\/power_transformer_no_load_2f_load_testing_equipment_with_wide_voltage_range.jpg","attrs":{"Brand Name":"Huaying","Model Number":"HYKF","Certification":"ISO","Place of Origin":"Wuhan Hubei China"}}
{"title":"Customized Transformer Testing Equipment For Measuring Short Circuit Voltage","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/d1\/23\/197dd14dd2c69c37af50c2a0c14b-200x200-1\/customized_transformer_testing_equipment_for_measuring_short_circuit_voltage.jpg","attrs":{"Brand Name":"Huaying","Model Number":"HYKF","Certification":"ISO","Place of Origin":"Wuhan Hubei China"}}
{"title":"Dielectric Loss Power Transformer Testing Kit Multi GST \/ UST \/ CVT \/ GST","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/2f\/15\/ef18d51b8270d2377015e1d87e6f-200x200-1\/dielectric_loss_power_transformer_testing_kit_multi_gst_2f_ust_2f_cvt_2f_gst.jpg","attrs":{"Place of Origin":"Wuhan Hubei China","Brand Name":"Huaying","Certification":"ISO","Model Number":"HYGS"}}
{"title":"ISO Transformer Turn Ratio Test Transformer Ratio Meter With CVT Function","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/58\/1e\/2e14d17046044043c4ae43bacf38-200x200-1\/iso_transformer_turn_ratio_test_transformer_ratio_meter_with_cvt_function.jpg","attrs":{"Place of Origin":"Wuhan Hubei China","Brand Name":"Huaying","Certification":"ISO","Model Number":"HYBC-901"}}
{"title":"Laboratory Standard Transformer Test Instruments No Load And Load Tester","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/f7\/0c\/fa96e9b928b4852c29be93c3781b-200x200-1\/laboratory_standard_transformer_test_instruments_no_load_and_load_tester.jpg","attrs":{"Brand Name":"Huaying","Model Number":"HYKF","Certification":"ISO","Place of Origin":"Wuhan Hubei China"}}
{"title":"Three Phase Integrated Transformer Testing Equipment High Accuracy 500 Groups","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/30\/e0\/d392e476dba54e1ca66e8cb4d421-200x200-1\/three_phase_integrated_transformer_testing_equipment_high_accuracy_500_groups.jpg","attrs":{"Place of Origin":"Wuhan Hubei China","Brand Name":"Huaying","Certification":"ISO","Model Number":"HYKFR"}}
Automatic Three Phase Power Transformer Turn Ratio and Vector Group Tester
1.Product Name:
Transformer Ratio Meter HYBC-901
2. Equipment Description:
HYBC-901 Tansformer ratio meter z type is specially designed for three- phase transformer in power system, especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.
3. Main Functions:
1 The voltage ratio measurement for three or singe phase transformer 2 The group vector measurement for three phase transformer. 3 The polarity measurement for single phase transformer or CT/PT 4 Voltage ratio error calculation 5 Current transformer ratio measurement 6 Excitation current measurement in ratio testing 7 Reproduction the AC test voltage from power source to reduce the effects of bad power source 8 Save the test results in the memory internal the tester 9 Print the test results by micro printer 10 Reverse connection detect unit to prevent the high voltage injected to operator 11 Over current protection unit integrated in software and hardware 12 Upload the test results to PC by RS232 and make word report by software
4.Technical Parameters:
1 Ratio measurement range:1~10000 2 Group measurement:1~12 3 Phase measurement error:1 degree 4 Ratio measurement error:1~2000 ± 0.2%RDG 2000~10000 ± 0.5%RDG 5 Test voltage:0~80V 6 Power supply:AC220V ± 10%, 50Hz/60Hz 7 Size 400´350´200 mm3 Weight 7kg Humidity: ≤85%RH
Wuhan Huaying Electric Power Tech & Science Co.,ltd, founded in 1997, engaged in the designing, manufacturing and selling of electrical test equipments.