Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"JB\/T 6855-93 Online Conductivity Meter For RO Water Plant System","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/ed\/df\/61c10941e8bfb935a29588d86242-200x200-1\/jb_2ft_6855_93_online_conductivity_meter_for_ro_water_plant_system.jpg","attrs":{"Brand Name":"Hongjie","Certification":"ISO 14001,ISO 9001,CE,EPA","Place of Origin":"Shenzhen,China","Minimum Order Quantity":"1set"}}
{"title":"Customized Ultrapure Water Equipment OEM Manufacturing Installation & Commission","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/40\/de\/f090877590a00f92a469e875e171-200x200-1\/customized_ultrapure_water_equipment_oem_manufacturing_installation_26_commissioning.jpg","attrs":{"Brand Name":"HongJie","Place of Origin":"Guangdong,China","Minimum Order Quantity":">=1sets","Price":"negotiation"}}
{"title":"High Performance PVDF Membrane Ultrafiltration Membranes For Ultrafiltration","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/da\/a4\/02b7ef4f7a8a51d1325fdcc3c5d0-200x200-1\/high_performance_pvdf_membrane_ultrafiltration_membranes_for_ultrafiltration_filter.jpg","attrs":{"Brand Name":"Hongjie","Certification":"ISO 14001,ISO 9001,CE,EPA","Place of Origin":"Shenzhen,China","Minimum Order Quantity":"2Sets"}}
{"title":"0.1MPa~0.6MPa Cation And Anion Exchangers For Water Treatment","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/5e\/d2\/739daf60c54e281043ac595d82f9-200x200-1\/0_1mpa_7e0_6mpa_cation_and_anion_exchangers_for_water_treatment.jpg","attrs":{"Brand Name":"Hongjie","Certification":"ISO 14001,ISO 9001,CE,EPA","Place of Origin":"Shenzhen,China","Minimum Order Quantity":"1set"}}
{"title":"Sainless Steel Panel Mounted Water Conductivity Tester For Pure Water Equipment","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/be\/15\/dc973bfb011deec6e7371fc93479-200x200-1\/sainless_steel_panel_mounted_water_conductivity_tester_for_pure_water_equipment.jpg","attrs":{"Brand Name":"Hongjie","Certification":"ISO 14001,ISO 9001,CE,EPA","Place of Origin":"Shenzhen,China","Minimum Order Quantity":"1set"}}
{"title":"Aromatic Polyamide Composite Reverse Osmosis Membrane For Water Purification","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/0b\/e2\/4d9584e73c687465cf1472f94306-200x200-1\/aromatic_polyamide_composite_reverse_osmosis_membrane_for_water_purification.jpg","attrs":{"Brand Name":"Hongjie","Model Number":"HJ-PWEle10T","Certification":"ISO 14001,ISO 9001,CE,EPA","Place of Origin":"Shenzhen,China"}}
The online conductivity meter features full Chinese display, Chinese menu operation, full intelligence, multi-function, high measurement performance, and strong environmental adaptability. When paired with an electrode with a constant of 1.0 or 10, the secondary meter can measure the conductivity of general liquids; when matched with an electrode with a constant of 0.1 or 0.01, it can accurately measure the conductivity of pure water or ultrapure water. It is particularly suitable for the online continuous monitoring of high-purity water conductivity such as power plant boiler feed water and steam condensate.
II.Technical Parameters
Standard
JB/T 6855-93 Industrial Conductivity Meter
Measurement Range
0.01~20μS/cm (with 0.01 electrode), up to 100.0μS/cm actually
0.1~200μS/cm (with 0.1 electrode), up to 1000.0μS/cm actually
1.0~2000μS/cm (with 1.0 electrode), up to 10.00mS/cm actually
10~20000μS/cm (with 10.0 electrode), up to 100.0mS/cm actually
Temperature Compensation
0~99.9℃, with 25℃ as reference temperature
Measured Water Sample
0~99.9℃, 0.6MPa
Basic Error
Conductivity: ±1.0%FS; Temperature: ±0.5℃ (0~60℃)
Repeatability
±0.2%FS
Stability
±0.2%FS
Isolated Current Output
0~10mA (load <1.5kΩ), 4~20mA (load <750Ω)
Output Current Error
≤±1%FS
Relay
AC220V, 3A
Communication Interface
RS485 (optional)
Power Supply
AC220V±22V, 50Hz±1Hz
Protection Grade
IP65
Clock Accuracy
±1 minute/month
Data Storage
1 month (1 point/5 minutes)
Dimensions
146 (length) × 146 (width) × 108 (depth) mm
III.Application Fields
● Power plants - water treatment;
● Waterworks and sewage plants - wastewater treatment;
● Papermaking - production process / wastewater treatment;
● Chemical industry and oil refining - production process / wastewater treatment;
● Metallurgy and mining - production process / wastewater treatment;
● Food and beverage - production process / wastewater treatment;
● Pharmaceutical industry - biological reaction and fermentation / wastewater treatment;
● Semiconductor - production process / wastewater treatment / high-purity water production.