Sheath Material | TPE |
Insulation Material | TPU |
Material Shape | Round Wire |
Cable Specification | 2C×80mm2+1C×25mm2+2C×4mm2+(3C×0.75mm2)(P2)+(7C×0.75mm2) |
Conductor Material | Bared copper stranded |
Rated Voltage | DC 1000V |
Rated Temperature | Jacket -40~90ºC, Insulation -40~125ºC |
Max Conductor Resistance | A:0.242Ω/km B:0.78Ω/km C:4.95Ω/km D&E:26Ω/km |
Insulation Voltage Withstand | AC 2.5kV/5min, leakage current ≤5mA |
Min Insulation Resistance | 500MΩ.km |
Tensile Strength | ≥20MPa |
Elongation | ≥300% |
Min Bend Radius | 6*OD |
Abrasion Resistance | ≥2000times |
Production Capacity | 20km/Day |
Certification | ISO9001, CE, CCC, RoHS |
View Detail Information
Explore similar products
EVJT Electric Vehicle Charging Cable EV Cable Multicore PVC Insulated Heat
OEM EV-RSS EV Charging Cable For EV AC Charging Station
EVJE EV Charging Cable For Electric Vehicles With Stranded Tinned / Bare Copper
TPE Sheath EVE EV Power Cable For Electric Vehicles Charging UL Certified
Product Specification
Sheath Material | TPE | Insulation Material | TPU |
Material Shape | Round Wire | Cable Specification | 2C×80mm2+1C×25mm2+2C×4mm2+(3C×0.75mm2)(P2)+(7C×0.75mm2) |
Conductor Material | Bared copper stranded | Rated Voltage | DC 1000V |
Rated Temperature | Jacket -40~90ºC, Insulation -40~125ºC | Max Conductor Resistance | A:0.242Ω/km B:0.78Ω/km C:4.95Ω/km D&E:26Ω/km |
Insulation Voltage Withstand | AC 2.5kV/5min, leakage current ≤5mA | Min Insulation Resistance | 500MΩ.km |
Tensile Strength | ≥20MPa | Elongation | ≥300% |
Min Bend Radius | 6*OD | Abrasion Resistance | ≥2000times |
Production Capacity | 20km/Day | Certification | ISO9001, CE, CCC, RoHS |
High Light | 1000V High Voltage EV Charging Cable ,ISO Certified EV Charging Cable ,RoHS Compliant EV Charging Cable |
SPECIFICATION | CABLE NAME | EV Cable | |||||
CABLE SPEC | 2C×80mm2+1C×25mm2+2C×4mm2+(3C×0.75mm2)(P2)+(7C×0.75mm2) | ||||||
RoHS Compliant | |||||||
Item | A : 2C×80mm2 | B : 1C×25mm2 | C : 1C×4mm2 | D:(3C×0.75mm2)(P2) | E:(7C×0.75mm2) | ||
CONDUCTOR | Material | Bared copper stranded | |||||
Size | 2580/0.20 ±0.008mm | 798/0.20 ±0.008mm | 224/0.15±0.008mm +10/1#Tinsel+1000D Kevlar | 40/0.15±0.008mm+ 10/0.19mmTinsel+200DKevlar | 40/0.15±0.008mm+ 10/0.19mmTinsel+200D Kevlar | ||
O.D.(Ref.) | 12.40±0.25mm | 7.00±0.20mm | 2.70±0.15mm | 1.40±0.10mm | 1.40±0.10mm | ||
INSULATION | Material | Thermoplastic(EF2585,85±3A) | |||||
Min. average thickness | 1.60mm | 1.20mm | 1.00mm | 0.50mm | 0.50mm | ||
Min.thickness at any point | 1.34mm | 0.98mm | 0.80mm | 0.35mm | 0.35mm | ||
O.D. | 15.60±0.40mm | 9.60±0.30mm | 4.70±0.20mm | 2.50±0.10mm | 2.50±0.10mm | ||
CABLING-1 | Filler | / | Cotton | Cotton | |||
Material | / | AL-mylar(facing out) | Non-woven | ||||
BRAID | Material | / | Tinned copper | / | |||
Size | / | 0.12mm,≥60% | / | ||||
In-JACKET | Material | / | TPE | TPE | |||
Min. average thickness | / | 0.60mm | 0.60mm | ||||
Min.thickness at any point | / | 0.42mm | 0.42mm | ||||
O.D. | / | 7.20±0.25mm | 9.70±0.25mm | ||||
CABLING | Filler | Strengthed PP rope | |||||
Material | Non-woven(≥25% overlapping) | ||||||
Assembly | 2C×80mm2+1C×25mm2+2C×4mm2+(3C×0.75mm2)(P2)+(7C×0.75mm2) | ||||||
JACKET | Material | TPU | |||||
Min. average thickness | 2.80mm | ||||||
Min.thickness at any point | 2.28mm | ||||||
O.D. | 38.00+0.6/-1.00mm |
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||||
Rated voltage:DC 1000V | Tensile strength:≥20MPa | High temperature pressure test:≤50% | |||||
Rated temperature:Jacket -40~90ºC | Elongation:≥300% | Heat shock test:No crack | |||||
Insulation -40~125ºC | Aged condition:110±1ºC×168h | Compatibility test:GB/T 33594 | |||||
Max. conductor resistance(20ºC): | Percent of original tensile strength:≤±30% | Crush resistance test:GB/T 33594 | |||||
A:0.242Ω/km B:0.78Ω/km C:4.95Ω/km D&E:26Ω/km | Percent of original elongation:≤±30% | Curved around the test:GB/T 33594 | |||||
Insulation Voltage withstand(Core A&B,10m): | Flame test:GB/T 18380.12-2008 | Min. Bend radius:6*OD | |||||
AC 2.5kV/5min,leakage current ≤5mA | Artificial weathering test:GB/T 33594 | Abrasion resistance:≥2000times | |||||
Completed cable Voltage withstand(Core A to A&B,10m): | Low-temperature impact test :-40ºC×16H,No crack | Resistance against chemicals:GB/T 33594 | |||||
AC 3.5kV/15min,leakage current ≤5mA | Chemical stress acid: N-Oxal-acid alkaline solution, N-sodium hydroxide solution:GB/T 33594 | ||||||
Min. Insulation resistance(20ºC, Core A to A&B):500MΩ.km | Vehicle rolling:Requirements and test methods should be consistent with GB/T 20234.1-2015 7.21 |
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
2000-2500
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Nantong Hwatek wire and cable Co., LTD was established in 2004,and located in #528 Xinsheng Road,Huaqiao international business park,Kunshan city.Factory Area:12000 square meters,300 sets of production and test instruments,production capability is over than 300 ton.In addition,we can make ... Nantong Hwatek wire and cable Co., LTD was established in 2004,and located in #528 Xinsheng Road,Huaqiao international business park,Kunshan city.Factory Area:12000 square meters,300 sets of production and test instruments,production capability is over than 300 ton.In addition,we can make ...
Get in touch with us