Payment Terms | T/T |
Supply Ability | 100 |
Delivery Time | 5-8 work days |
Packaging Details | New in original box |
Brand | GE Fanuc |
Model | IC693MAR590 |
Series | Series 90-30 |
Number of channels | 8 inputs/8 outputs |
Rated input voltage | 0 to 132 Volts AC |
Rated output voltage | 5 to 30 Volts DC / 5 to 250 Volts AC |
Isolation voltage | 1500 Volts RMS between field and logic side / 500 Volts RMS between inputs |
Maximum output load | 2 Amps |
Maximum inrush | 5 Amps |
warranty | 1 year |
Brand Name | GE |
Model Number | IC693MAR590 |
Place of Origin | USA |
View Detail Information
Explore similar products
ABB 3BSE038415R1 S800 Analog Input Output Module AO810V2 ASEA BROWN BOVER
AI810 Digital I O Module 3BSE008516R1 , AC Input Module 1x8 Channels 50V
2x8Ch Digital Input Relay Remote Input Output Module ABB 3BSE008552R1 DI811
ABB CI810B Digital I O Module 3BSE020520R1 AF100 Field Communication Interface
Product Specification
Payment Terms | T/T | Supply Ability | 100 |
Delivery Time | 5-8 work days | Packaging Details | New in original box |
Brand | GE Fanuc | Model | IC693MAR590 |
Series | Series 90-30 | Number of channels | 8 inputs/8 outputs |
Rated input voltage | 0 to 132 Volts AC | Rated output voltage | 5 to 30 Volts DC / 5 to 250 Volts AC |
Isolation voltage | 1500 Volts RMS between field and logic side / 500 Volts RMS between inputs | Maximum output load | 2 Amps |
Maximum inrush | 5 Amps | warranty | 1 year |
Brand Name | GE | Model Number | IC693MAR590 |
Place of Origin | USA | ||
High Light | 24VDC Negative Logic Input module ,24VDC Positive Logic Input Module ,2A Negative Logic Output Module |
The GE Fanuc IC693MAR590 is a 120 volt AC Input/Relay Output module. Equipped with eight input points, this module is designed to work with the Series 90-30 Programmable Logic Controller. The eight input points share a common power input terminal and it also has eight normally-open relay circuits. The input circuits are grouped together but the output points are split in two groups of four. Each output group has a common power output terminal. The module can operate pushbuttons, electronic proximity switches and limit switches due to its input characteristics. The user just needs to supply an external AC power source.
Each open relay circuit has an output switching capacity of 2 amps. These outputs may be used to control load devices as supplied by the user. For example, the module can control solenoids, indicators, and motor starters. This module has no fuses but it does have an LED block on top. This shows the status of the input points (the top row – A1 to A8) and the output points (the bottom row B1 to B8).
There is a door on the module. Users can use the door card for recording information about circuit identification or circuit wiring. This card has a red color code, which lets users know that this is a high-voltage module. Like similar models, this one can be installed in either a 5-slot or 10-slot baseplate to use it in a Series 90-30 PLC system. Any I/O slot is compatible with the IC693MAR590 Input/Relay Output module.
No. of channels: | 8 Inputs/8 Outputs |
Input Voltage Range: | 0 to 132 volts AC |
Output Voltage Range: | 5 to 30 volts DC, 5 to 250 volts AC |
Max Output Load: | 2 Amps |
Response Time: | 15 msec |
Power Consumption: | 80 mA from 5 VDC, 70 mA from relay 24 VDC |
Inputs
Rated Voltage 120 volts AC
Input Voltage range 0 to 132 volts AC
Inputs per Module 8 (one group of eight inputs)
Isolation 1500 volts RMS between field and logic side
500 volts RMS between inputs
Input Current 12 mA (typical) at rated voltage
Input Characteristics
On-State Voltage 74 to 132 volts AC
Off-State Voltage 0 to 20 volts AC
On-State Current 6 mA (minimum)
Off-State Current 2.2 mA (maximum) 30 ms typical
On Response Time 30 ms typical
Off Response Time 45 ms typical
Outputs
Rated Voltage 24 VDC, 120/240 VAC
Operating Voltage 5 to 30 volts DC
5 to 250 volts AC, 50/60 Hz
Outputs per Module 8 (two groups of four outputs each)
Isolation 1500 volts RMS between field and logic side
500 volts between groups
Maximum Load + 2 amps maximum per output
4 amps maximum per common 10 mA
Minimum Load 10 mA
Maximum Inrush 5 amps
On Response Time 15 ms maximum
Off Response Time 15 ms maximum
Internal Power Consumption 80 mA (all I/O on) from +5V backplane bus
70 mA (all outputs on) from relay +24V backplane bus
Company Details
Business Type:
Importer,Exporter,Trading Company,Seller
Year Established:
2010
Total Annual:
1000000-5000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
Shenzhen Wisdomlong Technology CO.,LTD Mainly engaged in automation parts, PLCS,DCS,sensors, relays, dirves,encoder, servo drive,soft starter,touch screen,instrument,process control,electric transmission and factory automation aspects of the project design,software programming,technical service and ... Shenzhen Wisdomlong Technology CO.,LTD Mainly engaged in automation parts, PLCS,DCS,sensors, relays, dirves,encoder, servo drive,soft starter,touch screen,instrument,process control,electric transmission and factory automation aspects of the project design,software programming,technical service and ...
Get in touch with us
Leave a Message, we will call you back quickly!