Payment Terms | T/T, Western Union |
Supply Ability | 100 |
Delivery Time | 2-3 work days |
Packaging Details | New in original box |
Brand | Schneider |
Model | 140DAO84210 |
Palce of Origin | FR |
Series | Quantum I/O |
Module Format | Standard |
Voltage drop | 1.5V |
Discrete output number | 16 |
Brand Name | Schneider |
Model Number | 140DAO84210 |
Place of Origin | FR |
View Detail Information
Explore similar products
Power Supply Redundancy Module Emerson KJ3201X1-BA1 Delta-V Dry Contact Card
3.3VDC 500mA Max Control Interface Module DELTAV KJ2004X1-BA1 12P2890X012
Electronic Interface Module / PLC Input Module KJ2002X1-CA1 VE3004 12P1509X092
Durable Emerson Redundant Power Supply Module VE3006 KJ2003X1-BB1 1.4AMP 5VDC
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 |
Delivery Time | 2-3 work days | Packaging Details | New in original box |
Brand | Schneider | Model | 140DAO84210 |
Palce of Origin | FR | Series | Quantum I/O |
Module Format | Standard | Voltage drop | 1.5V |
Discrete output number | 16 | Brand Name | Schneider |
Model Number | 140DAO84210 | Place of Origin | FR |
High Light | analog interface module , plc power supply module |
Redundant Power Supply Module SCHNEIDER AUTOMATION 140-DAO-842-10 OUTPUT MODULE 140DAO84210
Manufacturer: | Modicon Quantum |
Series: | Quantum I/O |
Weight: | Ask |
Product or component type: | AC discrete output modules |
Discrete output number: | 16 |
Group of channels: | 4 groups of 4 channels |
Supply frequency: | 47...63 Hz |
Voltage drop: | 1.5 V |
Discrete output voltage: | 83...253 V AC |
Addressing requirement: | 1 output word |
Absolute maximum output: | 400 Vrms 1 cycle AC |
300 Vrms for 10 s AC | |
Minimum load: | 5 A |
Minimum load current: | 4 A rms per group |
4 A rms 85...132 V per output | |
3 A rms 170...253 V per output | |
2.5 mA rms 230 Vrms off state leakage per output | |
2 mA rms 115 Vrms off state leakage per output | |
16 A rms per module | |
1 mA rms off state leakage per output | |
Surge current: | <= 45 A during 1 cycle per group |
<= 30 A during 2 cycles per group | |
<= 30 A during 1 cycle per point | |
<= 25 A during 3 cycles per group | |
<= 20 A during 2 cycles per point | |
<= 10 A during 3 cycles per point | |
DV/Dt: | 400 V/ms |
Response time: | <= 0.5 ms at state 1 to state 0 |
<= 0.5 ms at state 0 to state 1 | |
Fault indication: | Blown fuse |
Loss of field power | |
Protection type: | Internal by RC filter |
Internal output protection by 5 A fuse | |
Power dissipation: | 1.85 + (1.1 V x total module load current) |
Marking: | CE |
Local signalling: | 16 LEDs green input status |
1 LED red external fault detected (F) | |
1 LED green bus communication is present (Active) | |
Bus current requirement: | 350 mA |
Module format: | Standard |
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Similar Products
140ACI03000
140ACI04000
140ACO02000
140ACO13000
140ARI03010
140AMM09000
140AVI03000
140AVO02000
140ATI03000
140DDI35300
140DDI84100
140DDI85300
140DAI74000
140DAI75300
140DAO85300
140DAO84000
140DAO84210
140DDO35300
140DDO84300
Estimated Shipping Size
Dimensions: 2" x 4" x 10" (5 cm x 10 cm x 25 cm)
Weight: 1 lbs 2 oz (0.51 kg)
Schneider 140-DAO-842-10 Output Module 140DAO84210 Sealed
PN: 140-DAO-842-10
140DAO84210
Schneider Automation Inc
PN: 140 DAO 842 10
140DAO84210
Output Module
AC Out 100-230V 4X4
TSX Quantum
112698
UPC Number: 3 595861 126985
PV: 00
RL: 77
DOM: 03-2002
Sealed In Factory Packaging
SIL
NOTE: For complete definitions and parameters related to SIL ratings refer to IEC 61508, "Functional safety of electrical/electronic/programmable electronic safety related systems". Provided here is a partial definition.
safety integrity level
discrete level (1 out of a possible 4) for specifying the safety integrity requirements of the safety functions to be allocated to the E/E/PE safety-related systems, where safety integrity level 4 has the highest level of safety integrity and safety integrity level 1 has the lowest
(Definition IEC 61508)
SIL2 project (application)
A project (application) that uses a Quantum Safety PLC (140 CPU 651 60S V1.00 or 140 CPU 671 60S V1.00) to implement Safety Functions in a Safety-Related System.
SIL3 project (application)
A project (application) that uses a Quantum Safety PLC (140 CPU 651 60S V2.00 or 140 CPU 671 60S V2.00) to implement Safety Functions in a Safety-Related System.
SIR
Safety Integrity requirement
Safety Integrity requirements are derived from a risk assessment and describe the likelihood of a Safety Function to be performed satisfactorily, for instance the degree of certainty necessary for the Safety Function to be carried out.
sniffingreading the configuration out of a PLC
SRS
safety requirements specification
specification containing all the requirements of the safety functions that have to be performed by the safety-related systems
(Definition IEC 61508)
Company Details
Business Type:
Importer,Exporter,Trading Company,Seller
Year Established:
2010
Total Annual:
1000000-5000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
Shenzhen Wisdomlong Technology CO.,LTD Mainly engaged in automation parts, PLCS,DCS,sensors, relays, dirves,encoder, servo drive,soft starter,touch screen,instrument,process control,electric transmission and factory automation aspects of the project design,software programming,technical service and ... Shenzhen Wisdomlong Technology CO.,LTD Mainly engaged in automation parts, PLCS,DCS,sensors, relays, dirves,encoder, servo drive,soft starter,touch screen,instrument,process control,electric transmission and factory automation aspects of the project design,software programming,technical service and ...
Get in touch with us