Payment Terms | T/T |
Supply Ability | 2000pcs/day |
Delivery Time | 15-45Days |
Packaging Details | Wooden shaft packaging 32*22*12cm Outer box size: 37*37*24cm |
Number Of Conductors | 4 |
Compatibility | Ethernet |
Conductor Amaterial | Bare Copper |
Jacket Color | Green |
Conductor Size | 23 AWG |
Cable Type | FFTP |
Length | 500 ft |
Conductor Material | Copper |
Frequency | 100 MHz |
Brand Name | ITI-LINK |
Model Number | ITI-CTF6A-012 |
Certification | UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS |
Place of Origin | SHENZHEN |
View Detail Information
Explore similar products
Blue Cat5e FUTP 24AWG 1000ft High Speed Network Cable for Shielded Ethernet
UTP CAT5E 4×2×24AWG Gray PVC Network Cable Bulk Sale High-Speed pass Fluke Test
1000FT CAT5E UTP 24AWG Plenum Rated PVC Jacket High Speed Ethernet Cable for
Solid UTP CMP PVC Cat5e Plenum Rated Cable 24AWG High Speed Network Cable 1000FT
Product Specification
Payment Terms | T/T | Supply Ability | 2000pcs/day |
Delivery Time | 15-45Days | Packaging Details | Wooden shaft packaging 32*22*12cm Outer box size: 37*37*24cm |
Number Of Conductors | 4 | Compatibility | Ethernet |
Conductor Amaterial | Bare Copper | Jacket Color | Green |
Conductor Size | 23 AWG | Cable Type | FFTP |
Length | 500 ft | Conductor Material | Copper |
Frequency | 100 MHz | Brand Name | ITI-LINK |
Model Number | ITI-CTF6A-012 | Certification | UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS |
Place of Origin | SHENZHEN | ||
High Light | Large Networks Solid CAT6A FFTP Cable ,Bulk CAT6A FFTP 23AWG Solid Cable |
Wholesale Bulk CAT6A FFTP 23AWG Solid Cable PVC High-Speed Data Transfer for Large Networks
Product Description:
Technical Parameters:
Conductor Size | 23 AWG |
Color | Green |
Cable Type | FFTP |
Category | CAT6A |
Insulation Material | HDPE |
Length | 500Ft |
Jacket Material | PVC |
Frequency | 500MHz |
Product Description: Wholesale Bulk CAT6A FFTP 23AWG Solid Cable PVC High-Speed Data Transfer for Large Networks | ||||||
Rev.: A | ECN Description: | |||||
Construction Item Description | Electrical Property | |||||
Conductor | Material | Bare Solid Copper(elongation: 19-24%) | Conductor Resistance at 20°C | ≤ 9.5 Ω / 100m | ||
OD | 23AWG | Resistance unbalance within a pair | ≤ 2% | |||
Insulation | Material | HDPE | Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V | >1500 MΩ / 100m | ||
OD | 1.01 ±0.01 mm | Mutual capacitance | 5600 pF / 100m MAX | |||
Average THK | 0.22 mm | Capacitance unbalance pair to ground at 800Hz or 1 kHz | ≤ 160 pF / 100m | |||
Color | 1p: white + 2 blue stripes & blue | Characteristic impedance at 100MHz | 100 ± 15 Ω | |||
2p: white + 2 orange stripes & orange | Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or 0.7 KV AC for 1 min | No breakdown | ||||
3p: white + 2 green stripes & green | Mechanical Property | |||||
4p: white + 2 brown stripes & brown | insulation | elongation before aging | ≥ 300% | |||
Pair Twist | Lay & Direction | 1p: S=19.0 mm (27%) | tensile strength before aging | ≥12 MPa | ||
2p: S=23.5 mm (35%) | elongation after aging | ≥ 150 % | ||||
3p: S=21.5 mm (31%) | tensile strength after aging | ≥10.5 MPa | ||||
4p: S=27.0 mm (40%) | jacket | elongation before aging | ≥ 150 % | |||
OD | / | tensile strength before aging | ≥ 13.5 MPa | |||
Inner Assemble | Lay | S=90 ± 5 mm | elongation after aging | ≥ 125 % | ||
Direction | according to the drawing | tensile strength after aging | ≥ 12.5 MPa | |||
Filler | / | Packing | ||||
OD | / | Drum | NA | |||
Filler | Ripcord | 300D | ||||
Drain Wire | Tinned Copper | |||||
Shield | Shield | Pair Shield & Aluminium Foil | ||||
Construction | / | |||||
Material | Aluminium (PET/ALU) | |||||
Coverage | ≥ 115% | |||||
Jacket | Material | PVC, 50P, -20~75℃ | ||||
Hardness | 81± 3 | |||||
OD | 7.5 ± 0.2 | |||||
Average THK | 0.60 ~ 0.70 | |||||
Color | according to the customer's requirements | |||||
Marking Color | Blue | |||||
Marking | according to the customer's requirements |
Transmission Properties | |||||||||
CAT6A ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013 | |||||||||
No. | Frequency | Attenuation (Max) | Propagation Delay (Max) | Propagation Delay Skew (Max) | Return Loss (Min) | NEXT (Min) | PS NEXT (Min) | EL-FEXT (Min) | PS EL-FEXT (Min) |
MHz | dB/100m | ns/100m | ns/100m | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | |
1 | 4 | 3.8 | 552 | 45 | 23.01 | 66.27 | 63.27 | 55.96 | 52.96 |
2 | 8 | 5.31 | 546.73 | 45 | 24.52 | 61.75 | 58.75 | 49.94 | 46.94 |
3 | 10 | 5.93 | 545.38 | 45 | 25 | 60.3 | 57.3 | 48 | 45 |
4 | 16 | 7.49 | 543 | 45 | 25 | 57.24 | 54.24 | 43.92 | 40.92 |
5 | 20 | 8.38 | 542.05 | 45 | 25 | 55.78 | 52.78 | 41.98 | 38.98 |
6 | 25 | 9.38 | 541.2 | 45 | 24.32 | 54.33 | 51.33 | 40.04 | 37.04 |
7 | 31.25 | 10.5 | 540.44 | 45 | 23.64 | 52.88 | 49.88 | 38.1 | 35.1 |
8 | 50 | 13.36 | 539.09 | 45 | 22.21 | 49.82 | 46.82 | 34.02 | 31.02 |
9 | 62.5 | 14.99 | 538.55 | 45 | 21.54 | 48.36 | 45.36 | 32.08 | 29.08 |
10 | 100 | 19.13 | 537.6 | 45 | 20.11 | 45.3 | 42.3 | 28 | 25 |
11 | 125 | 21.51 | 537.22 | 45 | 19.43 | 43.85 | 40.85 | 26.06 | 23.06 |
12 | 200 | 27.58 | 536.55 | 45 | 18 | 40.78 | 37.78 | 21.98 | 18.98 |
13 | 250 | 31.07 | 536.28 | 45 | 17.32 | 39.33 | 36.33 | 20.04 | 17.04 |
14 | 300 | 34.27 | 536.08 | 45 | 17.3 | 38.14 | 35.14 | 18.46 | 15.46 |
15 | 350 | 37.25 | 535.92 | 45 | 17.3 | 37.14 | 34.14 | 17.12 | 14.12 |
16 | 400 | 40.05 | 535.8 | 45 | 17.3 | 36.27 | 33.27 | 15.96 | 12.96 |
17 | 450 | 42.71 | 535.7 | 45 | 17.3 | 35.5 | 32.5 | 14.94 | 11.94 |
18 | 500 | 45.26 | 535.61 | 45 | 17.3 | 34.82 | 31.82 | 14.02 | 11.02 |
Electrical Properties | ||
Conductor Resistance at 20°C | NF EN 50289-1-2 / IEC 60189-1 | ≤ 9.5 Ω / 100m |
Resistance unbalance within a pair | NF EN 50289-1-2/ IEC 60708 | ≤ 5% |
Dielectric Strength Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min | NF EN 50289-1-3 / IEC 61196-1-105 | No breakdown |
Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V | NF EN 50289-1-4 / IEC 60885-1 | >1500 MΩ / 100m |
Mutual capacitance | NF EN 50289-1-5 /IEC 60189-1 | 5600pF / 100m MAX |
Capacitance unbalance pair to ground at 800Hz or 1 kHz | NF EN 50289-1-5 / IEC 60189-1 | ≤ 160 pF / 100m |
Characteristic impedance at 100MHz | NF EN 50289-1-11/ IEC 61156-1 | 100 ± 15 Ω |
Spark Test | UL444 | 2000 ± 250VOC |
Applications:
FAQ:
Q: What is the brand name of this CAT6A cable?
A:The brand name of this CAT6A cable is ITI-LINK.
Q: What is the model number of this CAT6A cable?
A:The model number of this CAT6A cable is ITI-CTF6A-012.
Q: Where is this CAT6A cable manufactured?
A:This CAT6A cable is manufactured in SHENZHEN.
Q: What is the maximum data transmission speed supported by this CAT6A cable?
A:This CAT6A cable supports data transmission speeds of up to 10Gbps.
Q: Is this CAT6A cable suitable for outdoor installations?
A:No, this CAT6A cable is designed for indoor use only.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2014
Total Annual:
100,000,000-150,000,000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a... New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a...
Get in touch with us
Leave a Message, we will call you back quickly!