China factories

China factory - Labnovation Technologies, Inc.

Labnovation Technologies, Inc.

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Hospitex Hema Screen Analyzer Hematology Reagents For WBC Differentiation
China Hospitex Hema Screen Analyzer Hematology Reagents For WBC Differentiation

  1. China Hospitex Hema Screen Analyzer Hematology Reagents For WBC Differentiation
  2. China Hospitex Hema Screen Analyzer Hematology Reagents For WBC Differentiation

Hospitex Hema Screen Analyzer Hematology Reagents For WBC Differentiation

  1. MOQ:
  2. Price:
  3. Get Latest Price

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

High Light Hospitex Hema Screen Analyzer Hematology ReagentsWBC differentiation Hematology ReagentsODM Hematology Reagent

Hematology Analyzer Reagents Hematology Reagent For Hospitex Hema Screen Analyzers

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Hospitex Hema Screen hematology analyzers. This product is for In Vitro Diagnostic Use only.

 

Specification

L-70010070 DILUENT HX 20L
L-70010075 LYSE HX 500ml
L-70010085 CLEANER HX 5L

Kit Composition

DILUENT HX NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
LYSE HX Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%
CLEANER HX

Sodium Sulfate<1.5%, Anti-microbial Agent<0.1%

Application

For use with Hospitex Hema Screen hematology analyzers.

 

Procedures

  • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the tubes into the LABNOVATION reagent boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.

Storage

Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.

The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.

 

Precautions

  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2001

  • Total Annual:

    10000000-50000000

  • Employee Number:

    100~600

  • Ecer Certification:

    Active Member

Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...

+ Read More

Get in touch with us

  • Reach Us
  • Labnovation Technologies, Inc.
  • 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
  • https://www.labnovationtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement