Payment Terms | T/T, L/C, Western Union, MoneyGram |
Supply Ability | 1 unit/ month |
Delivery Time | 35 working days |
Packaging Details | Plywood case |
SKYLINE | Wire and Cable Fire Resistance Test Device |
Outlet pressure | 0.1Mpa±3Pa |
Pressure gauge | 0-200kPa |
Accuracy | ±1%, |
Repeatability | <0.2%Rd |
Brand Name | SKYLINE |
Model Number | SL802 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
SAE-J 1128-2005 11-2008 Fire Testing Equipment Vertical Flammability Tester For
ISO 6722 Fire Testing Equipment Automotive Single Core Wire / Cable Flammability
Horizontal Flammability Tester Chamber Safety for Electrical Wires , Cables and
IEC61034 Fire Testing Equipment Wires & Cables Smoke Density Test Room
Product Specification
Payment Terms | T/T, L/C, Western Union, MoneyGram | Supply Ability | 1 unit/ month |
Delivery Time | 35 working days | Packaging Details | Plywood case |
SKYLINE | Wire and Cable Fire Resistance Test Device | Outlet pressure | 0.1Mpa±3Pa |
Pressure gauge | 0-200kPa | Accuracy | ±1%, |
Repeatability | <0.2%Rd | Brand Name | SKYLINE |
Model Number | SL802 | Certification | CE |
Place of Origin | China | ||
High Light | 200kPa Fire Resistance Tester ,BS 8491 Fire Resistance Tester ,BS 8491 Fire Testing Equipment |
Product introduction
Detect the fire resistance of cables for wiring or power grids, burn in flames not lower than 750°C and 830°C, and detect cables to maintain the integrity of the circuit. The complete set of tests includes the fire resistance test methods specified by BS 8491.
Technical parameters
1. Separate design of gas and test test bench and circuit and console, safe and reliable;
2. Standard sample support frame, metal ring and support frame are all well grounded;
3. The gas system is composed of a pressure reducing valve, a pressure gauge, a mass flow meter, a Venturi mixer and a burner;
4. Imported gas pressure reducing valve provides a stable outlet pressure of 0.1Mpa±3Pa;
5. Imported pressure gauge, providing 0-200kPa pressure display;
6. Imported mass flow meter, accuracy of ±1%, repeatability <0.2%Rd.;
7. Imported venturi mixer, the mixing ratio is adjustable;
8. The standard recommends American AGF burner, model: 1857B;
9. Equipped with flame calibration device, using American OMEGA 1.5mm K type thermocouple, the calibration result is directly displayed on the software;
10. The flame time can be set and automatically cut off, without human monitoring, with ignition device;
11. The voltage of the transformer is adjustable, can adapt to the working voltage of different products, and can provide sufficient test voltage when the test current leaks;
12. Provide 5 test voltages, transformers and fuses in series, and provide circuit breakers to protect each test circuit;
13. The test circuit is connected in series with the bulb, and the sound and light alarm are provided to provide intuitive judgment instructions;
14. The standard requires spray device and mechanical impact device, and the test procedure is automatically controlled;
15. The standard requires spray device and mechanical impact device, and the test procedure is automatically controlled;
16. 15-inch industrial touch control computer, easy to operate and use;
17. Standard operating software, with functions such as test control, data recording, data processing, and report output.
Main equipment module
1. The main console, electrical control, and software acquisition integrated control cabinet;
2. Wall-mounted control box is used for different test methods to choose different modes;
3. Fire-resistant test platform for N-type cable testing;
4. Fire-resistant percussion spray integrated test platform for NJ cable testing;
5. Fire-resistant percussion jet integrated test platform for NS type cable testing.
What is fire resistance cable?
The definition of a fire-resistive or fire-rated cable is a cable that will continue to operate in the presence of a fire. This is commonly known as a circuit integrity (CI) cable and is 2-hour fire-rated. ... This 2-hour fire-resistive cable is designed for emergency power circuits for fire pumps and emergency generators.
What is a fire test?
A fire test can also mean an ad hoc test performed to gather information in oder to understand a specific hazard, such as a consturction or storage configuration.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Importer,Exporter,Seller
Year Established:
2011
Total Annual:
120000-350000
Employee Number:
100~107
Ecer Certification:
Verified Supplier
SKYLINE (DONGGUAN SKYLINE INDUSTRIAL CO.,LTD) provides full line of Toys Testing Equipment, Fire Testing Equipment ,Flammability Testing Equipment,Tensile Test Machine, Furniture Testing Machines ,Textile Testing Equipment and other lab test equipment .We also offers value added support service... SKYLINE (DONGGUAN SKYLINE INDUSTRIAL CO.,LTD) provides full line of Toys Testing Equipment, Fire Testing Equipment ,Flammability Testing Equipment,Tensile Test Machine, Furniture Testing Machines ,Textile Testing Equipment and other lab test equipment .We also offers value added support service...
Get in touch with us
Leave a Message, we will call you back quickly!