Rated voltage | 36 kV |
MOCV | 29 kV |
Nominal Current | 10 kV |
Steep impulse residual | 106 kV at 5kA |
Lightning impulse residual | 98 kV at 5kA |
Switching impulse residual | 75 kV at 1kA |
DC reference voltage | 51 kV at 1mA |
Line discharge level | 1 |
Long duration current | 400 A at 2mS |
High current impulse | 100 kA at 4/10µS |
Lightning withstand | 200 kV |
Power frequency withstand | 70 kV (dry/wet) |
0.1S TOV | 43.2 kV |
1S TOV | 41.4 kV |
10S TOV | 39.6 kV |
View Detail Information
Explore similar products
21kV,5kA polymer lightning arrester/surge arrester
KEMA Outdoor Substation Substation Lightning Arrester 220kV , Brown / Gray Color
102KV 10KA Porcelain Lightning Arrester in Substation MOA Type Brown Color
500KV HV Substation Lightning Arrester for Lighting Surge Protection Self
Product Specification
Rated voltage | 36 kV | MOCV | 29 kV |
Nominal Current | 10 kV | Steep impulse residual | 106 kV at 5kA |
Lightning impulse residual | 98 kV at 5kA | Switching impulse residual | 75 kV at 1kA |
DC reference voltage | 51 kV at 1mA | Line discharge level | 1 |
Long duration current | 400 A at 2mS | High current impulse | 100 kA at 4/10µS |
Lightning withstand | 200 kV | Power frequency withstand | 70 kV (dry/wet) |
0.1S TOV | 43.2 kV | 1S TOV | 41.4 kV |
10S TOV | 39.6 kV | ||
High Light | substation surge arrester with warranty ,lightning protection arrester for substation ,YH10W-36 surge arrester |
1.Surge Arrester Drawing2.Surge Arrester Working Condition
3.Surge arrester other information
About us
Our company is founded in 1993year, with advanced technology and talents. To provide customers with the most satisfactory product quality and thoughtful service. We hope to develop together with you hand in hand,and make both of us win-win. I hope the majority of buyers can come visit and tour company,your satisfaction is our greatest pursuit.
Production Lead Time & Quality Guarantee:
sample deliery time is about 2-3days
big order quantity is about 30-35 days after we receive 30%~50% deposit from you.
Generally,it takes 4 working days by DHL/UPS ,and 7-10days by EMS
12months' warranty period. 20years' quality guarantee period
With ISO9001:2008approvals.
Customer Services:
Our salesmen will reply your inquiry within 24 hours. Any order is welcome. If you like to be our agent in your
country, we can give you any support on the technique & other aspects.
Type | YH10W5-36/98 | ||
Rated voltage---------kV | 36 | 4/10µS High current impulse kA | 100 |
MOCV ----------------kV | 29 | Lightning impulse withstand kV | 200 |
Nominal Current-------kV | 10 | Power frequency voltage withstand(dry/wet)kV | 70 |
Residual voltage of steep impulse----at 5kA(kV) | 106 | 0.1S TOV--------------kV | 43.2 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)-----at 5kA(kV) | 98 | 1S TOV----------------kV | 41.4 |
Residual voltage of switching impulse current kV (peak value)----at 1kA (kV) | 75 | 10S TOV---------------kV | 39.6 |
1mA D.C reference voltage (kV) | 51 | 1200S TOV-------------kV | 36 |
Line discharge level | 1 | Creepage distance ----mm | 1148 |
2mS long duration impulse current A | 400 | Material employed in series non-linear resistor | Zinc Oxide |
Company Details
Business Type:
Manufacturer
Year Established:
1993
Total Annual:
$17,364,156-$20,744,408
Employee Number:
100~250
Ecer Certification:
Verified Supplier
Hangzhou Yongde Electric Appliances Co.,Ltd was founded in 1993. As a high-new-tech enterprise in Zhejiang province, it is about 15 kilometers from downtown area. Our Company is one of the recommended model companies for national power grid construction and transformation. We specialize... Hangzhou Yongde Electric Appliances Co.,Ltd was founded in 1993. As a high-new-tech enterprise in Zhejiang province, it is about 15 kilometers from downtown area. Our Company is one of the recommended model companies for national power grid construction and transformation. We specialize...
Get in touch with us
Leave a Message, we will call you back quickly!