At Linke cable, we believe there's a better way to bring better cables to market. We use an engineer-to-engineer approach
to develop better cables for customers and improve the quality of one's life.
Packaging Details | According to requirement |
Delivery Time | 7-15 days |
Payment Terms | Advance 30% deposit and ship after receiving 70% final payment |
Supply Ability | 50000m/day |
Origin | China |
Model NO. | type 1 |
Color | Black |
IP Grade | IP65 |
Lead Time | 7-15days |
Phase | Three Phase |
Customization | Available |
Rated Current | 32A |
Cable Length | 5meter or Custom |
Name | Charging Cable |
Shipping Cost | about shipping cost and estimated delivery time. |
Return&refunds | You can apply for a refund up to 30 days after receipt of the products. |
Copper | Tinned Copper |
Package Size | 850.00cm * 850.00cm * 580.00cm |
Core | Multiple |
Jacket 1 | TPU |
Jacket 2 | XLPE |
conductor material | copper/Tinned Copper |
Conductor Type | Twisted wire |
Exterior material | customize:PVC、PE、LSFOH、silicone rubber |
insulating materials | customize:PVC、PE 、XLPE、EPR、SIR |
specifications | 0.1-450mm² |
rated voltage | 300-600V |
rated temperature | -60± 200℃ |
type | insulated |
package | By roll |
Place of Origin | Guangdong, China |
Brand Name | Linke |
Certification | UL;ISO9001;ISO13485;IATF16949;TPU |
View Detail Information
Explore similar products
Super Soft Performance Silicone Jacket Electric Vehicle Cable for Manufacture
Insulated High Voltage Copper Conductor XLPE Rubber Cable for Energy Electric
Energy Cable Multiple Core Design TPU Jacket for Powerline Wire in Energy
Type 2 to Type 2 250V/480V 16A/32A Electric Vehicles Charging Cable Assembly
Product Specification
Packaging Details | According to requirement | Delivery Time | 7-15 days |
Payment Terms | Advance 30% deposit and ship after receiving 70% final payment | Supply Ability | 50000m/day |
Origin | China | Model NO. | type 1 |
Color | Black | IP Grade | IP65 |
Lead Time | 7-15days | Phase | Three Phase |
Customization | Available | Rated Current | 32A |
Cable Length | 5meter or Custom | Name | Charging Cable |
Shipping Cost | about shipping cost and estimated delivery time. | Return&refunds | You can apply for a refund up to 30 days after receipt of the products. |
Copper | Tinned Copper | Package Size | 850.00cm * 850.00cm * 580.00cm |
Core | Multiple | Jacket 1 | TPU |
Jacket 2 | XLPE | conductor material | copper/Tinned Copper |
Conductor Type | Twisted wire | Exterior material | customize:PVC、PE、LSFOH、silicone rubber |
insulating materials | customize:PVC、PE 、XLPE、EPR、SIR | specifications | 0.1-450mm² |
rated voltage | 300-600V | rated temperature | -60± 200℃ |
type | insulated | package | By roll |
Place of Origin | Guangdong, China | Brand Name | Linke |
Certification | UL;ISO9001;ISO13485;IATF16949;TPU | ||
High Light | Type1 Extension EV Charger Cable ,3Phase EV Charger Cable ,50A EV Charger Cable |
16A 32A Type 2 Electric Vehicle EV Charging Cable with TUV&UL
Reference Standard:UL 2263
UL No.:E364879
Construction | Features |
1.Conductor | Rated temperature:-50℃~105℃ |
Material: Bare Copper | Rated Voltage:1000V |
2.Insulation | Conductor Resistance(at 20°C):8AWG≤2.23Ω/km;10AWG≤3.51Ω/km;16AWG≤14.1Ω/km;Test method Comply with UL 2556 |
Material: TPE | 15°C Insulation Resistance:8AWG≥34Ω.m;10AWG≥34Ω.m;16AWG≥45Ω.m;Test method Comply with UL 2556 |
Color:Black,red,Green/Yellow or other | Dielectric Voltage: 4.0kV AC/1min(8AWG),3.0KV AC/1min(10AWG), 2.0KV AC/1min(16AWG). No Breakdown. Test method Comply with UL 2556 |
3.Filler | Bending Radius Min:≥6OD. |
Material: cotton yarn | Hot Shock:150℃/1h No cracks Test method Comply with UL 2556 |
4.Tape | Flame Test:FT1.Test method Comply with UL 2556 |
Material:Non-woven fabrics | Insulation tensile strength:Before Aging 5.5Mpa;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556 |
5.Sheath | Insulation Elongation:Before Aging200%;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556 |
Material: TPE | Jacket tensile strength:Before Aging 8.3Mpa;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556 |
Color: Black or Orange | Jacket Elongation:Before Aging200%;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556 |
| Cold Bending Test:-40°C/4H,NO Cracking.Test method Comply with UL 2556 |
| Hot Shock Test:150°C/1H,NO Cracking.Test method Comply with UL 2556 |
Type | Main Lines Size & E | Signal Lines Size | Permissible ampacity@20°C ambient Ref. | Over diameter Ref. mm |
EVC 1001 | 10AGW/2+10AGW | 22AGW(20AGW/18AGW/16AGW)0-6 | 32A | 12.0±0.5 |
EVC 1002 | 9AGW/2+10AGW | 40A | 13.8±0.5 | |
EVC 1003 | 8AGW/2+10AGW | 48A | 15.0±0.5 | |
EVC 1004 | 6AGW/2+8AGW | 80A | 18.9±0.5 | |
EVC 1005 | 3AGW/4+12AGW(14AGW/10AGW) | 18AGW(20AGW/22AGW)0-8 | 170A(200A) | 28.3±1.0 |
EVC 1006 | 2AGW/4+12AGW(14AGW/10AGW) | 200A(250A) | 31.0±1.0 | |
EVC 1007 | 1/0AGW/4+12AGW(14AGW/10AGW) | 300A-350A | 36.5±1.0 | |
EVC 1008 | 4AGW/2+14AGW | 120A | 21.0±1.0 | |
EVC 1009 | 1AGW/4+14AGW |
| 250A(300A) | 34.0±1.0 |
UL 2263 EV charging cable (Suitable for CCS1)
Reference Standard:UL 2263
UL No.:E364879
Construction | Features |
1.Conductor | Rated temperature:-40℃~105℃ |
Material: Bare Copper | Rated Voltage:300V;600V or 1000V |
2.Insulation | Flame Test: VW-1 Test method Comply with UL 2556 |
Material: TPE | Min: Bending Radius: ≥6*OD |
colour:Black,Red,Green/Yellow or other | Dielectric Voltage: 1.5kVac/1min. No Breakdown Test method Comply with UL 2556 |
3.Filler | Cold Bending:-40℃/4h No cracks Test method Comply with UL 2556 |
Material: cotton yarn | Hot Shock:150℃/1h No cracks Test method Comply with UL 2556 |
4.Tape | Oil Resistance:IRM902, 60℃/168h Tensile and Elongation ≥70% Unaged value |
Material:Non-woven fabrics | Crush Resistance:S≤12AWG 4.45kN, 12AWG<S≤2AWG, 11.1kN, 2AWG<S 15.6kN |
5.Sheath | Weather Resistance:720hin a xenon arc weatherometer, No cracks |
Material: TPE | Environmental Requirements:Compliant with RoHS |
Color: Black or Orange(customizable) |
Type | Size | Conductor Stranded OD mm Ref. | Max. Conductor resistance mΩ/m@20℃ | Permissible ampacity@20℃ ambient Ref. | Over diameter Ref. mm | Packing M/Reel (Ref.) |
600V or 1000V EVE(TPE) | 3×16AWG | 1.5/1.2 | 14.1 | 12A | 10.8±0.5 | 1000m/700# |
3×14AWG | 1.9/1.2 | 8.88 | 16A | 11.8±0.5 | 800m/700# | |
3×12AWG | 2.4/1.2 | 5.58 | 23A | 14.3±0.5 | 500m/700# | |
3×10AWG | 3.0/1.2 | 3.51 | 32A | 15.6±0.5 | 500m/700# | |
2×8AWG+10AWG | 4.3/3.0 | 2.23/3.51 | 46A | 20.9±0.8 | 500m/950# | |
2×6AWG+8AWG | 5.4/4.3 | 1.40/2.23 | 63A | 23.4±0.8 | 400m/950# | |
3×16AWG+1×18AWG | 1.5/1.2 | 14.1/22.4 | 12A | 11.4±0.5 | 800m/700# | |
3×14AWG+1×18AWG | 1.9/1.2 | 8.88/22.4 | 16A | 13.5±0.5 | 500m/700# | |
3×12AWG+1×18AWG | 2.4/1.2 | 5.58/22.4 | 23A | 14.5±0.5 | 500m/700# | |
3×10AWG+1×18AWG | 3.0/1.2 | 3.51/22.4 | 32A | 15.8±0.6 | 500m/700# | |
2×8AWG+10AWG+18AWG | 4.3/3.0 | 2.23/3.51/22.4 | 46A | 20.9±0.8 | 500m/950# | |
2×6AWG+8AWG+18AWG | 5.4/4.3 | 1.40/2.23/22.4 | 63A | 23.4±0.8 | 400m/950# | |
2×4AWG+6AWG+18AWG | 6.6/5.4 | 0.882/1.4/22.4 | 75A | 27.0±0.9 | 300m/950# | |
3×16AWG+2×18AWG | 1.5/1.2 | 3.51/22.4 | 12A | 12.2±0.5 | 500m/700# | |
3×14AWG+2×18AWG | 1.9/1.2 | 8.88/22.4 | 16A | 14.1±0.5 | 500m/700# | |
3×12AWG+2×18AWG | 2.4/1.2 | 5.58/22.4 | 23A | 15.1±0.6 | 500m/700# | |
3×10AWG+2×18AWG | 3.0/1.2 | 3.51/22.4 | 32A | 15.8±0.6 | 500m/700# | |
2×8AWG+10AWG+2×18AWG | 4.3/3.0 | 2.23/3.51 | 46A | 20.9±0.8 | 500m/950# | |
2×6AWG+8AWG+2×18AWG | 5.4/4.3 | 1.40/2.23 | 63A | 23.4±0.8 | 400m/950# | |
2×4AWG+6AWG+2×18AWG | 6.6/5.4 | 0.882/1.4 | 75A | 27.0±0.9 | 300m/950# | |
2×2AWG+4AWG+2×18AWG | 8.2/6.6 | 0.555/0.882 | 100A | 30.5±1.0 | 400m/1200# | |
2×1/0AWG+2AWG+4×16AGW | 10.5/8.2 | 0.349/0.555 | 200A | 38.0±1.0 | 250m/1200# | |
2×3/0AWG+1/0AWG (2×3/0AWG+4AWG+6X18AWG) 3/0AWG Ground line minimum 4AWG | 13.05/10.5 | 0.219/0.349 | 260A | 45.0±1.0 | 150m/1200# | |
4X1-0AWG+4AWG+6X18AWG | 10.4/6.5 | 0.351/0.882/23.6 | 300A/350A | 45.7±1.2 | 150m/1200# | |
300V EVJE(TPE) | 3×16AWG | 1.5/1.2 | 3.51/22.4 | 12A | 9.5±0.3 | 1200m/700# |
3×14AWG | 1.9/1.2 | 8.88/22.4 | 16A | 10.2±0.5 | 1000m/700# | |
3×12AWG | 2.4/1.2 | 5.58/22.4 | 23A | 11.4±0.5 | 800m/700# | |
3×16AWG+1×18AWG | 1.5/1.2 | 3.51/22.4 | 12A | 10.5±0.5 | 1000m/700# | |
3×14AWG+1×18AWG | 1.9/1.2 | 8.88/22.4 | 16A | 11.1±0.5 | 80m/700# | |
3×12AWG+1×18AWG | 2.4/1.2 | 5.58/22.4 | 23A | 12.2±0.5 | 500m/700# | |
3×16AWG+2×18AWG | 1.5/1.2 | 3.51/22.4 | 12A | 11.3±0.5 | 800m/700# | |
3×14AWG+2×18AWG | 1.9/1.2 | 8.88/22.4 | 16A | 12.0±0.5 | 800m/700# | |
3×12AWG+2×18AWG | 2.4/1.2 | 5.58/22.4 | 23A | 13.1±0.5 | 500m/700# | |
The number of signal wires can be 0~6, or more, the signal wire conductor specifications can be 16AWG, 18AWG, 20AWG, 22AWG. |
The above product specifications, sizes, and structures may be changed due to technological progress. Similar specifications can be designed and manufactured according to customer needs.
Wire and cable manufacturer Linke Cable Technology Co., Ltd is a leading cable supplier in China. In the past over 10 years,
Linke Cable has been focusing on R&D, production and marketing of wire and cable. Linke provide various cables&custom
cable solutions for all over the world. We are specialized in EV charging cable, medical cable, silicone cable, spring cable,
braided cable, towlobe cable, UL wire, automotive cable, etc.
At Linke cable, we believe there's a better way to bring better cables to market. We use an engineer-to-engineer approach
to develop better cables for customers and improve the quality of one's life.
Exhibition:
We past UL1007,UL1185,UL1672,UL10070,UL10483,UL1015,UL1569,UL10012,UL10269
(Single conductor,thermoplastic insulation)
UL2095,UL2129,UL2468,UL2586,UL2725,UL20233,UL20280,UL20963,UL2103,UL2463,UL2517,UL2587,UL2835,
UL20276,UL20549,UL21198,2104,UL2464,UL2576,UL2661,UL2919,UL20279,UL20886,UL21664
ISO9001 and ISO13485,TS16949
CNR- Appliance Wiring Material,
Extruded PVC Insulated Single,rated 105ºC,1000V,ClassI,GroupA,B,or AB, FT1 and/or FT2.
Extruded PVC Non-integral Jacketed Cable, rated 105"C, 1000V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2.
Extruded TPU Non-integral Jacketed Cable, rated 80"C, 300V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2
1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last.
Welcome to visit us. We'll pick you up in Shenzhen.
2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy.
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.
4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us.
5. Does your company accept OEM production?
Yes, could print your company name, we even custom the quality card to promote your company
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
800000-1000000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
Linke cable technology (DongGuan) Co. Ltd. Concentrate on R&D and provide professional solutions to the Cable&Wire, especially for the different industry customers. It contains: Measuring& Control devices cable, Medical equipment cable, Automotive & Rail transit cable, EV charging ca... Linke cable technology (DongGuan) Co. Ltd. Concentrate on R&D and provide professional solutions to the Cable&Wire, especially for the different industry customers. It contains: Measuring& Control devices cable, Medical equipment cable, Automotive & Rail transit cable, EV charging ca...
Get in touch with us
Leave a Message, we will call you back quickly!