China One Step Rapid Drug Abuse Test Kit Fit Heroin Treatment 24 Months Shelf Life
China One Step Rapid Drug Abuse Test Kit Fit Heroin Treatment 24 Months Shelf Life

  1. China One Step Rapid Drug Abuse Test Kit Fit Heroin Treatment 24 Months Shelf Life
  2. China One Step Rapid Drug Abuse Test Kit Fit Heroin Treatment 24 Months Shelf Life

One Step Rapid Drug Abuse Test Kit Fit Heroin Treatment 24 Months Shelf Life

  1. MOQ: 5000pcs
  2. Price: USD0.5-USD5
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 2000000pcs/month
Delivery Time 20-30days
Packaging Details 1pc/pouch, 25pcs/box
Category Drug Abuse kits
Format strip
Specimen Urine
Testing time 5-15 minutes
Shelf Life 24 Months
application MTD
cut-off 300ng
Brand Name New Life
Model Number strip
Certification ISO13485, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 2000000pcs/month
Delivery Time 20-30days Packaging Details 1pc/pouch, 25pcs/box
Category Drug Abuse kits Format strip
Specimen Urine Testing time 5-15 minutes
Shelf Life 24 Months application MTD
cut-off 300ng Brand Name New Life
Model Number strip Certification ISO13485, CE
Place of Origin China
High Light self testing drug kits drug test strips

Drug Abuse Test Kit MTD Rapid Diagnostic Test strip, professional use, 300ng/ml cut-off, detecting Methadone in urine

 

Product Name

 
MTD Rapid Diagnostic Test/ Methadone Rapid Diagnostic Test
Specimen: Urine
 
 
Intended Use
 
 
Methadone is a narcotic pain reliever for medium to severe pain. It is also used in the treatment of Heroin (Opiate dependence: Vicodin, Percolate, Morphine, etc) addiction. Oral Methadone is very different than the IV Methadone. Oral Methadone is partially stored in the liver for later use. IV Methadone acts more like Heroin.
 
Methadone is a long acting pain reliever producing effects that last between twelve to forty-eight hours. Ideally, Methadone frees the client from the pressures of obtaining illegal Heroin, from the dangers of injection, and from the emotional roller coaster that most Opiates produce. Methadone, if taken for long periods and at large doses, can lead to a very long withdrawal period. The withdrawals from Methadone are more prolonged and troublesome than those provoked by heroin cessation, yet the substitution and phased removal of methadone is an acceptable method of detoxification for patients and therapists.1
The MTD One Step Methadone Test Strip (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Methadone in urine. The MTD One Step Methadone Test Strip (Urine) yields a positive result when the Methadone in urine exceeds 300ng/mL.
 
 

ParameterCalibratorCut-off (ng/mL)
MTD (Methadone)Methadone300

 
 
Test Principle
 

The MTD One Step Methadone Test Strip (Urine) is a rapid chromatographic immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.

During testing, a urine specimen migrates upward by capillary action. Methadone, if present in the urine specimen below 300 ng/mL, will not saturate the binding sites of antibody-coated particles in the test strip. The antibody-coated particles will then be captured by immobilized Methadone conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Methadone level exceeds 300 ng/mL because it will saturate all the binding sites of anti-Methadone antibodies.

A drug-positive urine specimen will not generate a colored line in the test line region, while a drug-negative urine specimen or a specimen containing a drug in a concentration less than the cut-off will generate a colored line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.
 
 
DIRECTIONS FOR USE
 

  1. Bring the pouch to room temperature before opening it. Remove the Test Dipstick from the sealed pouch and use it within one hour.
  2. With arrows pointing towards the urine specimen, immerse the Test Dipstick vertically in the urine specimen in such a way that urine does not cross MAX line on the Test Dipstick for 10-15 seconds. See the illustration below.
  3. Wait for the color line(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

 
 
INTERPRETATION OF RESULTS
 
 
NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.
 
*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.
 
POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.
 
INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.
 
 
QUALITY CONTROL
 
A procedural control is included in the test. A line appearing in the control region
(C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.
Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.
 
 

 
Performance characteristics
 
Analytical Sensitivity
 
A drug-free urine pool was spiked with Methadone at the following concentrations: 0 ng/mL, 0 ng/mL, 150 ng/mL, 225 ng/mL, 300 ng/mL, 375 ng/mL, 450 ng/mLand600 ng/mL. The result demonstrates > 99% accuracy at 50% above and 50% below the cut-off concentration. Results are presented in Table 2 below.
 
Table 2: Analytical Sensitivity Summary
 

MTD Concentration (ng/mL)Percent of Cut-offnVisual Result
NegativePositive
0030300
150-50%30291
225-25%30246
300Cut-off30219
375+25%30228
450+50%30030
600+100%30030

 
 
Conclusion: As indicated in table above: all specimens with MTD concentration equal to or lower than 150ng/mL show negative results, all specimens with MTD concentration of 300ng/mL are identified as “+/-”, and all specimens with MTD concentration equal to or higher than 450ng/mL showed positive results. Therefore, the cut-off concentration of the MTD One Step Methadone Test Strip (Urine) is determined to be 300ng/mL MTD.
 
 
Analytical Specificity
 

Table 3 lists the compounds that are positively detected in urine by the MTD One Step Methadone Test Strip (Urine) at 5 minutes and the concentrations at which they are detected.

 
Table 3: Analytical Specificity
 

CompoundConcentration (ng/mL)
Methadone300
Doxylamine50,000

 

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry

























































Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2009

  • Total Annual:

    10,000,000-15,000,000

  • Employee Number:

    200~300

  • Ecer Certification:

    Active Member

Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...

+ Read More

Get in touch with us

  • Reach Us
  • Orient New Life Medical Co.,Ltd.
  • 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
  • https://www.medicaldiagnostictestkits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement