Payment Terms | T/T, Western Union |
Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days |
Packaging Details | 1pc/pouch, 25pcs/box |
Category | Infectious |
Format | Strip/cassette |
Specimen | Feces |
Testing time | 5-15 minutes |
Shelf Life | 24 Months |
Application | Norovirus Ag |
Accuracy | 94.29% |
Brand Name | New Life |
Model Number | Cassette |
Certification | ISO13485,CE |
Place of Origin | China |
View Detail Information
Explore similar products
High Accuracy One Step Syphilis Rapid Diagnostic test Whole Blood/SerumPlasma
High Accuracy One Step Gonorrhea Rapid Diagnostic test cassette , gold colloidal
High Accuracy HBsAb (Hepatitis B surface antibody ) Rapid Diagnostic test
One Step High accuracy Strep B Rapid Diagnostic test , quick and easily, gold
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days | Packaging Details | 1pc/pouch, 25pcs/box |
Category | Infectious | Format | Strip/cassette |
Specimen | Feces | Testing time | 5-15 minutes |
Shelf Life | 24 Months | Application | Norovirus Ag |
Accuracy | 94.29% | Brand Name | New Life |
Model Number | Cassette | Certification | ISO13485,CE |
Place of Origin | China | ||
High Light | infection blood test ,bacterial infection blood test |
One Step Norovirus Rapid Test, Feces specimen,gold colloidal method,Detection Norovirus antigen, high accuracy
Accessories:
Test cassettes | Package insert |
Specimen collection tube with extraction buffer |
Intended Use:
The Norovirus Rapid Test Cassette (Feces) is a rapid chromatographic immunoassay for the qualitative detection of Norovirus in human feces specimens to aid in the diagnosis of Norovirus infection.
Test Principle:
The Norovirus Test Cassette (Feces) is a qualitative, lateral flow immunoassay for the detection of Norovirus in human feces specimens.
The assay uses Genogroup 1 and Genogroup 2 specific monoclonal antibodies coated on the test membrane. During testing, the stool specimen reacts with the conjugate antibodies. The mixture migrates upward on the membrane chromatographically by capillary action to react with Genogroup 1 and 2 antibodies on the membrane and generates a colored line at the level of the T1 and T2 zone respectively. The presence of a colored line in T1 region indicates a positive result for Genogroup 1 and in T2 region for Genogroup 2 respectively, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control reaction zone (C) indicating that proper volume of specimen has been added and membrane wicking has occurred.
TEST PROCEDURE
Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.
1. Specimen collection and pre-treatment:
1) Use clean, dry containers for specimen collection. Best results will be obtained if the assay is performed within 6 hours after collection.
2) For solid specimens: Unscrew and remove the dilution tube applicator. Becareful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces to collect approximately 50 mg of feces (equivalent to 1/4 of a pea).
For liquid specimens: Hold the pipette vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 80 µL) into the specimen collection tube containing the extraction buffer.
3) Replace the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube.
Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation.
2. Testing
1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. For best results, the assay should be performed within one hour.
2) Using a piece of tissue paper, break the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device.
Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result window.
As the test begins to work, color will migrate across the membrane.
3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.
Note: If the specimen does not migrate due to the presence of particles, centrifuge the extracted specimens contained in the extraction buffer vial. Collect 100 µL of supernatant, dispense into the specimen well (S) of a new test device and start again, following the instructions described above.
INTERPRETATION OF RESULTS
POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).
*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.
NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
PERFORMANCE CHARACTERS:
Sensitivity, Specificity and Accuracy
The performance of the Norovirus Rapid Test Cassette has been evaluated with 70 clinical specimens collected from children and young adults in comparison with RT-PCR method. The results show that the relative sensitivity of the Norovirus Rapid Test Cassette (Feces) is 95.65% and the relative specificity is 91.67%.
One Step Norovirus Rapid Test Cassette vs. RT-PCR
Method | RT-PCR | Total Results | ||
One Step Norovirus Rapid Test Cassette | Results | Positive | Negative | |
Positive | 44 | 2 | 46 | |
Negative | 2 | 22 | 24 | |
Total Results | 46 | 24 | 70 |
Relative Sensitivity: 95.65% (95%CI:*85.16%-99.57%)
Relative Specificity: 91.67% (95%CI:*73.00%-98.97%)
Relative Accuracy: 94.29% (95%CI:*86.01%-98.42%) *Confidence Intervals
ORIENT NEW LIFE MEDICAL CO., LTD. | |
Contact: | Jerry Meng |
Email: | Jerry @ newlifebiotest .com |
Tel. | +86 18657312116 |
SKYPE | enetjerry |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Total Annual:
10,000,000-15,000,000
Employee Number:
200~300
Ecer Certification:
Active Member
Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...
Get in touch with us
Leave a Message, we will call you back quickly!