Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Packaging Details | Wooden case |
Type | Blood Testing Equipments |
Name | BSC Biosafety Cabinet |
Overall size | 1500×800×2120mm |
Purification area size | 1300×700×600mm |
Product name | Biosafety cabinet |
Model | BSC-1300B2 |
Downflow velocity | 0.31±0.025m/s |
Inflow velocity | 0.48±0.025m/s |
Brand Name | HAIYING |
Model Number | BSC-1300B2 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Hospital College Laboratory BSC Biosafety Cabinet LCD Display
ISO 5 Class II BSC Biological Safety Cabinet CE HEPA
100 Level Protection BSC Biosafety Cabinet UV Sterilization
Laminar Ductless Bsl 2 Biosafety Cabinet Class 2 Thermo Scientific
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Packaging Details | Wooden case |
Type | Blood Testing Equipments | Name | BSC Biosafety Cabinet |
Overall size | 1500×800×2120mm | Purification area size | 1300×700×600mm |
Product name | Biosafety cabinet | Model | BSC-1300B2 |
Downflow velocity | 0.31±0.025m/s | Inflow velocity | 0.48±0.025m/s |
Brand Name | HAIYING | Model Number | BSC-1300B2 |
Certification | CE | Place of Origin | CHINA |
High Light | B2 Ductless Biosafety Cabinet ,B2 ISO 5 biosafety cabinets ,BSC Ductless Biosafety Cabinet |
BSC Biosafety Cabinet Features:
1. High-quality material front window.
2. Timing function.
3. HEPA filter life and UV life indicator.
4. Automatic wind speed with filter is adjustable.
5. With power-off memory function.
6. Audiovisual alarm (abnormal airflow speed; filter replacement; front window is at an unsafe height.)
7. The working area is surrounded by negative pressure, which can ensure the maximum safety of the working area.
8. Audiovisual alarm (filter replacement, high-altitude windows, abnormal airflow speed, etc.)
9. Remote control: all functions can be realized, making the operation easier.
10. Interlocking function; UV lamp and front window; UV lamp and blower, LED lamp; Blower and front window.
Model | BSC-1300B2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1500×800×2120mm |
Working Space | 1300×700×600 mm |
Downflow Velocity | 0.35m/s |
Forward intake wind speed | 0.25m/s±0.025m/s |
Principles for choosing BSC Biosafety Cabinet in biosafety laboratories:
When the laboratory level is level 1, there is generally no need to use a biological safety cabinet or a level I biological safety cabinet. When the laboratory level is level two, when microbial aerosols or spills may occur, a level I biological safety cabinet can be used; when handling infectious materials, a level II biological safety cabinet with partial or full ventilation should be used ; If it involves handling chemical carcinogens, radioactive substances and volatile solvents, only Class II-B full exhaust (B2 type) biological safety cabinets can be used. When the laboratory level is level three, a level II or level III biological safety cabinet should be used; all operations involving infectious materials should use a fully exhausted type II-B level (B2 type) or level III biological safety cabinet. When the laboratory level is level four, a level III full exhaust biological safety cabinet should be used. When personnel wear positive pressure protective clothing, a Class II-B biological safety cabinet can be used.
Installation of BSC Biosafety Cabinet:
1. The biological safety cabinet shall not be placed on its side, impacted, or collided during transportation, and shall not be directly attacked by rain, snow, or sun exposure.
2. The working environment of the biological safety cabinet is 10~30℃ and the relative humidity is <75%.
3. The equipment should be installed on a horizontal surface that cannot be moved.
4. The equipment must be installed close to a fixed power socket. When the external exhaust system is not connected, the top of the device must be at least 200mm away from the obstacle at the top of the room, and the distance between the back and the wall must be at least 300mm to facilitate the smooth flow of external exhaust. Maintenance of safety cabinets.
5. In order to prevent airflow interference, it is required not to install the equipment in the passage of people, and not to make the operating port of the sliding front window of the biological safety cabinet face the door and window of the laboratory or be too close to the door and window. Places that may disturb the airflow.
6. When used in high altitude areas, the wind speed must be recalibrated after installation.
Company Details
Business Type:
Distributor/Wholesaler,Trading Company
Year Established:
2016
Total Annual:
1800000-2000000
Employee Number:
80~90
Ecer Certification:
Active Member
The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality... The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality...
Get in touch with us
Leave a Message, we will call you back quickly!