Payment Terms | L/C, T/T |
Supply Ability | 3000 pieces every month |
Delivery Time | 30 workdays |
Packaging Details | Package by the box |
Model | YH Composite Cover Zinc Oxide Arrester |
Certificate | ISO9001 & SGS Factory Audit Report |
Material | malleable iron , aluminum,Composite resin |
Color | red |
Usage | Transmission Line |
Install | easy |
Brand Name | FUTAO |
Model Number | YH |
Certification | ISO 9001 |
Place of Origin | Jiangsu China |
View Detail Information
Explore similar products
Wires and Cables, Power Fittings Switches And Other Standard Parts
FR Series Stockbridge Vibration Damper pole accessories
P-20 P-20-Y 11kv 11kn pin insulator pole accessories
33kv High voltage Column Insulator Pin insulator PS-15 pole accessories
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 3000 pieces every month |
Delivery Time | 30 workdays | Packaging Details | Package by the box |
Model | YH Composite Cover Zinc Oxide Arrester | Certificate | ISO9001 & SGS Factory Audit Report |
Material | malleable iron , aluminum,Composite resin | Color | red |
Usage | Transmission Line | Install | easy |
Brand Name | FUTAO | Model Number | YH |
Certification | ISO 9001 | Place of Origin | Jiangsu China |
High Light | power pole hardware ,electric power fittings |
YH Composite Cover Zinc Oxide Arrester for Transmission Line
Description:
The product has passed the type test and technical demonstration of national insulator arrester quality supervision and Inspection Center With excellent protection characteristics, the power frequency continuous current can be effectively cut off in an instant through the series gap formed between the lead ring and the conductor and the cooperative action of current limiting elements, so as to avoid the accident of conductor lightning breaking.
Unique interface coupling technology and one-time forming process of silicone rubber outer casing ensure reliable sealing, safety and explosion-proof of products; silicone rubber outer casing is resistant to climate aging, electric erosion, pollution, safe and reliable operation, maintenance free.
Even if the protector is damaged due to abnormal conditions, due to the isolation function of series gap, the insulation coordination level will not be affected to ensure the operation safety of the power system.
Composite Cover Arrester Parameter List:
Voltage grade | Use place | System Nominal Voltage Effective Value (kV) |
Arrester GB model | Arrester Rated Voltage Effective Value (kV) |
Gapless Arrester | Gap Arrester | Residual Voltage (kV) Peak (<) | 2000μs square wave flow capacity (A) | 4/10 Large Current Tolerance (kA) | ||||||
Arrester continuous operating voltage (kV) effective value | DC 1mA reference voltage (kV) ≥ | 0.75 times DC reference voltage Max leakage (μA) | Power frequency discharge voltage (kV) effective value ≥ | 1.2-50 peak discharge voltage (kV) peak ≤ | Max conductive current (μA) | 8/20 lightning impulse current | 30/36 operating impulse current | 1/4 steep wave impulse current | |||||||
Low pressure | Distribution type | 0.22 | YH1.5W-0.28/1.3 | 0.28 | 0.24 | 0.6 | 50 | - | - | - | 1.3 | - | - | 75 | 25 |
0.38 | YH1.5W-0.5/2.6 | 0.5 | 0.42 | 1.2 | 50 | - | - | - | 2.6 | - | - | 75 | 25 | ||
Motor type | 0.66* | YH2.5WD-1.3/3.6 | 1.3 | 0.95 | 1.8 | 50 | - | - | - | 3.6 | - | - | 200 | 40 | |
1.14* | YH2.5WD-2.6/7.2 | 2.6 | 1.9 | 3.6 | 50 | - | - | - | 7.2 | - | - | 200 | 40 | ||
3kV | Distribution type | 3 | YH5WS-3.8/15 | 3.8 | 2.0 | 7.5 | 50 | - | - | - | 15 | 12.8 | 17.3 | 75 | 40 |
3 | YH5WS-5/15 | 5 | 4.0 | 7.5 | 50 | - | - | - | 15 | 12.8 | 17.3 | 75 | 40 | ||
3 | YH5CS-3.8/15 | 3.8 | - | - | - | 9.0 | 13.5 | 20 | 13.5 | 11.4 | 15 | 75 | 40 | ||
Power station type | 3 | YH5WZ-3.5/13.5 | 3.8 | 2.0 | 7.2 | 50 | - | - | - | 13.5 | 11.5 | 15.5 | 200 | 65 | |
3 | YH5WZ-5/12.0 | 5 | 4.0 | 7.2 | 50 | - | - | - | 13.5 | 11.5 | 15.5 | 200 | 65 | ||
3 | YH5CZ-3.8/12.0 | 3.8 | - | - | - | 8.0 | 12.0 | 20 | 12.0 | 10.2 | 13.5 | 200 | 65 | ||
Capacitive type | 3 | YH5WR-3.8/13.5 | 3.8 | 2.0 | 7.2 | 50 | - | - | - | 13.5 | 10.5 | - | 400 | 65 | |
3 | YH5WR-5/13.5 | 5 | 4.0 | 7.2 | 50 | - | - | - | 13.5 | 10.5 | - | 400 | 65 | ||
3 | YH5CR-3.8/12.0 | 3.8 | - | - | - | 8.0 | 12.0 | 20 | 12.0 | 9.6 | - | 400 | 65 | ||
Generator type | 3.15* | YH5WD-3.8/9.5 | 3.8 | 2.0 | 5.7 | 50 | - | - | - | 9.5 | 7.6 | 10.7 | 400 | 65 | |
3.15* | YH5WD-4/9.5 | 4 | 3.15 | 5.7 | 50 | - | - | - | 9.5 | 7.6 | 10.7 | 400 | 65 | ||
3.15* | YH5CD-3.8/8.6 | 3.8 | - | - | - | 7.5 | 8.6 | 20 | 8.6 | 6.9 | 9.8 | 400 | 65 | ||
Electric Motor type | 3.15* | YH2.5WD-3.8/9.5 | 3.8 | 2.0 | 5.7 | 50 | - | - | - | 9.5 | 7.6 | 10.7 | 200 | 65 | |
3.15* | YH2.5WD-4/9.5 | 4 | 3.15 | 5.7 | 50 | - | - | - | 9.5 | 7.6 | 10.7 | 200 | 65 | ||
3.15* | YH2.5CD-3.8/8.6 | 3.8 | - | - | - | 7.5 | 8.6 | 20 | 8.6 | 6.9 | 9.8 | 200 | 65 | ||
Neutral point type | 3.15* | YH1.5W-2.4/6 | 2.4 | 1.9 | 3.4 | 50 | - | - | - | 6.0 | 5.0 | - | 200 | 65 | |
6kV | Distribution type | 6 | YH5WS-7.6/30 | 7.6 | 4.0 | 15.0 | 50 | - | - | - | 30.0 | 25.6 | 34.6 | 75 | 40 |
6 | YH5WS-10/30 | 10 | 8.0 | 15.0 | 50 | - | - | - | 30.0 | 25.6 | 34.6 | 75 | 40 | ||
6 | YH5CS-7.6/27 | 7.6 | - | - | - | 16.0 | 27.0 | 20 | 27.0 | 22.5 | 30.0 | 75 | 40 | ||
Power station type | 6 | YH5WZ-7.6/27 | 7.6 | 4.0 | 14.4 | 50 | - | - | - | 27.0 | 23.0 | 31.0 | 200 | 65 | |
6 | YH5WZ-10/27 | 10 | 8.0 | 14.4 | 50 | - | - | - | 27.0 | 23.0 | 31.0 | 200 | 65 | ||
6 | YH5CZ-7.6/24 | 7.6 | - | - | - | 16.0 | 24.0 | 20 | 24.0 | 20.4 | 27.0 | 200 | 65 | ||
Capacitive type | 6 | YH5WR-7.6/27 | 7.6 | 4.0 | 14.4 | 50 | - | - | - | 27.0 | 21.0 | - | 400 | 65 | |
6 | YH5WR-10/27 | 10 | 8.0 | 14.4 | 50 | - | - | - | 27.0 | 21.0 | - | 400 | 65 | ||
6 | YH5CR-7.6/24 | 7.6 | - | - | - | 16.0 | 24.0 | 20 | 24.0 | 19.5 | - | 400 | 65 | ||
Generator type | 6.3* | YH5WD-7.6/18.7 | 7.6 | 4.0 | 11.2 | 50 | - | - | - | 18.7 | 15.0 | 21.0 | 400 | 65 | |
6.3* | YH5WD-8/18.7 | 8 | 6.3 | 11.2 | 50 | - | - | - | 18.7 | 15.0 | 21.0 | 400 | 65 | ||
6.3* | YH5CD-7.6/17 | 7.6 | - | - | - | 15.0 | 17.0 | 20 | 17.0 | 13.8 | 19.6 | 400 | 65 | ||
Electric motor type | 6.3* | YH2.5WD-7.3/18.7 | 7.6 | 4.0 | 11.2 | 50 | - | - | - | 18.7 | 15.0 | 21.0 | 200 | 65 | |
6.3* | YH2.5WD-8/18.7 | 8 | 6.3 | 11.2 | 50 | - | - | - | 18.7 | 15.0 | 21.0 | 200 | 65 | ||
6.3* | YH2.5CD-7.6/17 | 7.6 | - | - | - | 15.0 | 17.0 | 17.0 | 13.8 | 19.6 | 200 | 65 | |||
Neutral point type | 6.3* | YH1.5W-4.8/12 | 4.8 | 3.8 | 6.8 | 50 | - | - | - | 12.0 | 10.0 | - | 75 | 65 | |
10kV | Distribution type | 10 | YH5WS-12.7/50 | 12.7 | 6.6 | 25 | 50 | - | - | - | 50 | 42.5 | 57.5 | 75 | 40 |
10 | YH5WS-17/50 | 17 | 13.6 | 25 | 60 | 26.0 | 45 | 20 | 50 | 42.5 | 57.5 | 75 | 40 | ||
10 | YH5CS-12.7/45 | 12.7 | - | - | - | - | - | 45 | 38.4 | 51.0 | 200 | 40 | |||
Power station type | 10 | YH5WZ-12.7/45 | 12.7 | 6.6 | 24 | 50 | - | - | 45 | 38.3 | 51.8 | 200 | 65 | ||
10 | YH5WZ-17/45 | 17 | 13.6 | 24 | 50 | - | - | - | 45 | 38.3 | 51.8 | 200 | 65 | ||
10 | YH5CS-12.7/41 | 12.7 | - | - | - | 26.0 | 41 | 20 | 41 | 35.0 | 46.0 | 200 | 65 | ||
Capacitive type | 10 | YH5WR-12.7/46 | 12.7 | 6.6 | 24 | 50 | - | - | - | 46 | 35.0 | - | 400 | 65 | |
10 | YH5WR-17/46 | 17 | 13.6 | 24 | 50 | - | - | - | 46 | 35.0 | - | 400 | 65 | ||
10 | YH5CR-12.7/41 | 12.7 | - | - | - | 26.0 | 41 | 20 | 41 | 33.0 | - | 400 | 65 | ||
Generator type | 10.5* | YH5WD-12.7/31 | 12.7 | 6.6 | 18.6 | 50 | - | - | - | 31 | 25 | 34.7 | 400 | 65 | |
10.5* | YH5WD-13.5/31 | 13.5 | 10.5 | 18.6 | 50 | - | - | - | 31 | 25 | 34.7 | 400 | 65 | ||
10.5* | YH5CD-12.7/28 | 12.7 | - | - | - | 25.0 | 25.0 | 20 | 28 | 22.5 | 32.0 | 400 | 65 | ||
13.8* | YH5WD-17.5/40 | 17.5 | 13.6 | 24.4 | 50 | - | - | - | 40.0 | 32.0 | 44.8 | 400 | 65 | ||
15.75* | YH5WD-20/45 | 20.0 | 15.75 | 28.0 | 50 | - | - | - | 45.0 | 36.0 | 50.4 | 400 | 65 | ||
18.0 | YH5WD-23/51 | 23.0 | 18.0 | 31.9 | 50 | - | - | - | 51.0 | 40.8 | 57.2 | 400 | 65 | ||
20.0* | YH5WD-25/56.2 | 25.0 | 20.0 | 35.4 | 50 | - | - | - | 56.2 | 45 | 62.9 | 400 | 65 | ||
Electric motor type | 10.5* | YH2.5WD-12.7/31 | 12.7 | 6.6 | 18.6 | 50 | - | - | - | 31 | 25 | 34.7 | 200 | 65 | |
10.5* | YH2.5WD-13.5/31 | 13.5 | 10.5 | 18.6 | 50 | - | - | - | 31 | 25 | 34.7 | 200 | 65 | ||
10.5* | YH2.5CD-12.7/28 | 12.7 | - | - | - | 25.0 | 28.0 | 20 | 28 | 22.5 | 32.0 | 200 | 65 | ||
Neutral point type | 10.5* | YH1.5W-8/19 | 8 | 6.4 | 11.4 | 50 | - | - | - | 19.0 | 15.9 | - | 400 | 65 | |
13.8* | YH1.5W--10.5/23 | 10.5 | 8.4 | 14.9 | 50 | - | - | - | 23.0 | 19.2 | - | 400 | 65 | ||
15.75* | YH1.5W-12/26 | 12 | 9.6 | 17.0 | 50 | - | - | - | 26.0 | 21.6 | - | 400 | 65 | ||
18.0* | YH1.5W-13.7/29.2 | 13.7 | 11.0 | 19.5 | 50 | - | - | - | 29.2 | 24.3 | - | 400 | 65 | ||
20.0* | YH1.5W-15.2/31.7 | 15.2 | 12.2 | 21.6 | 50 | - | - | - | 31.7 | 26.4 | - | 400 | 65 | ||
35kV | Power station type | 35 | YH5WZ-51/134 | 51 | 40.8 | 73 | 50 | - | - | - | 134 | 114 | 154 | 400 | 65 |
35 | YH5WZ-42/134 | 42 | 23.4 | 73 | 50 | - | - | - | 134 | 114 | 154 | 400 | 65 | ||
35 | YH5CZ-42/134 | 42 | - | - | - | 80.0 | 124 | 20 | 124 | 100 | 143 | 400 | 65 | ||
Capacitive type | 35 | YH5WR-51/134 | 51 | 40.8 | 73 | 50 | - | - | - | 134 | 105 | - | 400 | 65 | |
35 | YH5CR-42/124 | 42 | - | - | - | 80.0 | 124 | 20 | 134 | 100 | - | 400 | 65 | ||
35 | YH5WR-42/134 | 42 | 23.4 | 73 | 50 | - | - | - | 124 | 105 | - | 400 | 65 | ||
Line type | 35 | YH5WX-51/134 | 51 | 40.8 | 73 | 50 | - | - | - | 134 | 114 | 154 | 400 | 65 | |
35 | YH5WX-54/150 | 54 | 43.2 | 77 | 50 | 80.0 | 120 | 20 | 150 | 128 | 169 | 400 | 65 | ||
35 | YH5CX-42/120 | 42 | - | - | - | 80.0 | 150 | 20 | 120 | 100 | 138 | 400 | 65 | ||
35 | YH5CX-42/150 | 42 | - | - | 50 | - | - | - | 150 | 128 | 169 | 400 | 65 | ||
Neutral point type | 35 | YH1.5W-30/80 | 30 | 24 | 44 | 50 | - | - | - | 80 | 67.5 | - | 400 | 65 | |
66kV | Power station type | 66 | YH5WZ-84/221 | 84 | 67.2 | 121 | 50 | - | - | - | 221 | 188 | 254 | 600 | 65 |
66 | YH5WZ-90/235 | 90 | 72.5 | 130 | 50 | - | - | - | 235 | 201 | 270 | 600 | 65 | ||
66 | YH10WZ-84/221 | 84 | 67.2 | 121 | 50 | - | - | - | 221 | 188 | 248 | 500 | 100 | ||
66 | YH10WZ-90/235 | 90 | 72.5 | 130 | 50 | - | - | - | 235 | 201 | 264 | 500 | 100 | ||
Line type | 66 | YH5WX-96/250 | 96 | 75 | 140 | 50 | - | - | - | 250 | 213 | 288 | 500 | 65 | |
66 | YH5WX-96/275 | 96 | 75 | 154 | 50 | - | - | - | 275 | 234 | 316 | 500 | 65 | ||
110kV | Power station type | 110 | YH5WZ-100/260 | 100 | 78 | 145 | 50 | - | - | - | 260 | 221 | 299 | 500 | 65 |
110 | YH5WZ-102/266 | 102 | 79.6 | 148 | 50 | - | - | - | 266 | 226 | 305 | 500 | 65 | ||
110 | YH5WZ-108/281 | 108 | 84 | 157 | 50 | - | - | - | 281 | 239 | 323 | 500 | 65 | ||
110 | YH10WZ-100/260 | 100 | 78 | 145 | 50 | - | - | - | 260 | 221 | 291 | 500 | 100 | ||
110 | YH10WZ-102/266 | 102 | 79.6 | 148 | 50 | - | - | - | 266 | 226 | 297 | 500 | 100 | ||
110 | YH10WZ-108/281 | 108 | 84 | 157 | 50 | - | - | - | 281 | 239 | 315 | 500 | 100 | ||
Line type | 110 | YH5WX-108/281 | 108 | 84 | 157 | 50 | - | - | - | 281 | 239 | 323 | 500 | 65 | |
110 | YH5WZ-108/309 | 108 | 84 | 173 | 50 | - | - | - | 309 | 263 | 348 | 500 | 65 | ||
110 | YH10WX-108/281 | 108 | 84 | 157 | 50 | - | - | - | 281 | 239 | 315 | 500 | 100 | ||
110 | YH10WX-108/309 | 108 | 84 | 173 | 50 | - | - | - | 309 | 263 | 348 | 500 | 100 | ||
110 | YH5CX-90/206 | 90 | - | 130 | 50 | 170* | 525* | - | 260 | - | 292 | 400 | 65 | ||
110 | YH10CX-90/260 | 90 | - | 130 | 50 | 170* | 525* | - | 260 | - | 292 | 600 | 100 | ||
110 | YH10CX-96/280 | 96 | - | 140 | 50 | 170* | 525* | - | 280 | - | 314 | 600 | 100 | ||
110 | YH10CX-102/296 | 102 | - | 148 | 50 | 170* | 525* | - | 296 | - | 332 | 500 | 100 | ||
Neutral point type | 110 | YH1.5W-60/144 | 60 | 48 | 85 | 50 | - | - | - | 144 | 135 | - | 400 | 65 | |
110 | YH1.5W-72/186 | 72 | 58 | 103 | 50 | - | - | - | 186 | 174 | - | 400 | 65 | ||
220kV | Power station type | 220 | YH10WZ-192/500 | 192 | 150 | 280 | 50 | - | - | - | 500 | 426 | 560 | 800 | 100 |
220 | YH10WZ-200/520 | 200 | 156 | 290 | 50 | - | - | - | 520 | 442 | 582 | 800 | 100 | ||
220 | YH10WZ-204/532 | 204 | 159 | 296 | 50 | - | - | - | 532 | 452 | 594 | 800 | 100 | ||
220 | YH10WZ-216/562 | 216 | 168.5 | 314 | 50 | - | - | - | 562 | 478 | 630 | 800 | 100 | ||
Line type | 220 | YH10WX-216/562 | 216 | 168 | 314 | 50 | - | - | - | 562 | 478 | 630 | 600 | 100 | |
220 | YH10WX-216/618 | 216 | 168 | 346 | 50 | - | - | - | 618 | 526 | 693 | 600 | 100 | ||
220 | YH10CX-185/520 | 180 | - | 260 | 50 | 340* | 900* | - | 520 | - | 584 | 600 | 100 | ||
220 | YH10CX-192/560 | 192 | - | 280 | 50 | 340* | 900* | - | 560 | - | 628 | 600 | 100 | ||
220 | YH10CX-204/592 | 204 | - | 296 | 50 | 340* | 900* | - | 592 | - | 664 | 600 | 100 | ||
Neutral point type | 220 | YH1.5W-144/320 | 144 | 116 | 205 | 50 | - | - | - | 320 | 299 | - | 600 | 65 | |
27.5kV | Railway Type | 27.5 | YH5WT-42/120 | 42 | 34 | 65 | 60 | - | - | - | 120 | 98 | 138 | 400 | 65 |
55kV | 55 | YH5WT-84/240 | 84 | 68 | 130 | 50 | - | - | - | 240 | 276 | 276 | 400 | 65 |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2000
Total Annual:
18000000-25000000
Employee Number:
100~130
Ecer Certification:
Verified Supplier
Our company focuses on manufacturing all kinds of metal poles. This includes steel power poles, street lamp poles, telecommunication poles and many more. Futao Metal Structures was founded in 2000 with one goal in mind - to provide quality products that you can count on. Since then, we have accumula... Our company focuses on manufacturing all kinds of metal poles. This includes steel power poles, street lamp poles, telecommunication poles and many more. Futao Metal Structures was founded in 2000 with one goal in mind - to provide quality products that you can count on. Since then, we have accumula...
Get in touch with us
Leave a Message, we will call you back quickly!