Supply Ability | 10 million meters per year |
Delivery Time | in one month |
Packaging Details | plywood crates |
Dimensions | 0.2"x0.3" (5mm x 8mm) 12 AWG |
Dielectric Strength | Over 2000 volts |
Property | As per project application |
Usage | Chemical Plant |
Flame Resistance | Good |
Wattage | 39Watt/meter |
Max. Exposure Temp. (°F) Power Off | 260 |
Voltages | Up to 480 |
Brand Name | MICH |
Model Number | EHTTSCP |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
380V MI Trace Heating Cables Hot Water Maintenance
Roll On To Roll Off Wharf Area Edible Oil Electric Heat Tracing 25KW
6X Heat Tracing On Pipe Liquefied Natural Gas Storage Plant
Mineral Insulated Heating Cable In Mine And Minerals
Product Specification
Supply Ability | 10 million meters per year | Delivery Time | in one month |
Packaging Details | plywood crates | Dimensions | 0.2"x0.3" (5mm x 8mm) 12 AWG |
Dielectric Strength | Over 2000 volts | Property | As per project application |
Usage | Chemical Plant | Flame Resistance | Good |
Wattage | 39Watt/meter | Max. Exposure Temp. (°F) Power Off | 260 |
Voltages | Up to 480 | Brand Name | MICH |
Model Number | EHTTSCP | Certification | ISO9001 |
Place of Origin | China | ||
High Light | 2000V Electric Heat Tracing ,Self Regulating Electric Heat Tracing ,2000V constant wattage heating cable |
Electric Heat Tracing Technical Solution for Chemical Plant is a package solution for the industrial processes to manufacture chemical product either in large scaled production or fine chemical production.
Electric Heat Tracing Technical Solution for Chemical Plant guarantees the maintenance of the temperature in the pipes, tanks and process equipment. That maintenance prevents any problem derived from losing temperature in processes: obstructions and breakages, increased viscosity in fluids, condensation of water steam in gases and phase shifts...
The solution normally uses parallel type heating cables (Self-regulating and/or Constant Power) and temperature control adapted to each process. All commanded by direct temperature and power control panels.
Here are five applications typically:
1. High Temperature Heat Tracing: for the use of temperature higher than 500°C
2. Long-Line Heating: for the use of pipeline more than 300 meters.
3. Freeze Protection: The main purpose of a freeze-protection system is to prevent fluids such as process water, drain water and fire water lines from freezing in pipes.
4. Process Temperature Maintenance without Steam Exposure: With process temperature-maintenance applications, there is usually a need for viscosity control of certain fluids such as fuel oils, acids and fertilizers at higher temperatures beyond freeze-protection applications.
5. Process Temperature Maintenance with Steam Exposure: In some freeze-protection and process temperature-maintenance applications, the heat-tracing cable is exposed to higher temperatures than the maintenance temperature when steam is used to clean the pipes.
Table 2 Heating Cable Specification (600V Single Conductor)
Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight |
mm | mm | Ω/m | m | kg/km | |
16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 |
16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 |
16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 |
16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 |
16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 |
16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 |
16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 |
16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 |
16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 |
16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 |
16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 |
16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 |
16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 |
16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 |
16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 |
16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 |
16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 |
16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 |
16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 |
16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 |
16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 |
16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 |
16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 |
16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 |
16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 |
Table 3 Heating Cable Specification (600V Double Conductors)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26C3.4 | 12.9 | 0.0034 | 150 | 783.76 |
26C4.4 | 12.2 | 0.0044 | 160 | 701.56 |
26C5.8 | 11.3 | 0.0058 | 170 | 606.16 |
26C8.6 | 9.90 | 0.0086 | 180 | 451.43 |
26C11.4 | 9.30 | 0.0114 | 200 | 400.05 |
26C13.8 | 9.00 | 0.0138 | 210 | 375.20 |
26C17.2 | 8.60 | 0.0172 | 220 | 344.90 |
26C23 | 8.00 | 0.023 | 250 | 303.25 |
26C34.4 | 7.50 | 0.0344 | 280 | 269.20 |
26C49.2 | 7.10 | 0.0492 | 300 | 243.84 |
26K240 | 9.90 | 0.24 | 180 | 451.43 |
26K320 | 9.30 | 0.32 | 200 | 400.05 |
26K384 | 9.00 | 0.384 | 210 | 375.20 |
26K480 | 8.60 | 0.48 | 220 | 344.90 |
26K640 | 8.00 | 0.64 | 250 | 303.25 |
26K960 | 7.50 | 0.96 | 280 | 269.20 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23C3.4 | 12.0 | 0.0034 | 200 | 708.10 |
23C4.4 | 11.3 | 0.0044 | 220 | 629.07 |
23C5.8 | 10.4 | 0.0058 | 240 | 537.73 |
23C8.6 | 9.00 | 0.0086 | 260 | 392.56 |
23C11.4 | 8.40 | 0.0114 | 280 | 343.89 |
23C13.8 | 8.00 | 0.0138 | 300 | 314.57 |
23C17.2 | 7.60 | 0.0172 | 320 | 286.27 |
23C23 | 7.10 | 0.023 | 340 | 252.98 |
23C34.4 | 6.60 | 0.0344 | 360 | 221.19 |
23C49.2 | 6.20 | 0.0492 | 380 | 197.64 |
23K160 | 10.4 | 0.16 | 220 | 508.37 |
23K240 | 9.00 | 0.24 | 240 | 392.56 |
23K320 | 8.40 | 0.32 | 265 | 343.89 |
23K384 | 8.00 | 0.384 | 280 | 314.57 |
23K480 | 7.70 | 0.48 | 300 | 291.91 |
23K640 | 7.10 | 0.64 | 320 | 252.98 |
23K960 | 6.50 | 0.96 | 350 | 216.11 |
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Selection Parameters:
Constant Wattage Heating Cable | High Temperature Heating cable | Polyamide/Fiberglass Heating Cable | Harsh Environment Heating Cable | General Purpose Heating Cable |
Available Voltages | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC |
Available Wattages
| 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 3, 5, 8 & 12 watts/ft (10, 16, 26 & 39 watts/m) |
Maximum Exposure Temperature | 500°F (260°C)
| 500°F (260°C)
| 500°F (260°C)
| 400°F (204°C)
|
Nominal Dimensions
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG |
Resistance to Moisture | Good | Good | Excellent
| Excellent
|
Resistance to Chemicals | Good | Good | Excellent
| Excellent
|
Resistance to Flame | Excellent | Outstanding | Excellent | Outstanding |
Dielectric Strength | Over 2000 volts | Over 2000 volts
| Over 2000 volts | Over 2000 volts |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Employee Number:
150~200
Ecer Certification:
Active Member
Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...
Get in touch with us
Leave a Message, we will call you back quickly!