Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability | 1,000,000M/year |
Delivery Time | 2-7 working days |
Packaging Details | 70*70*8cm Carton |
Core | 2,3,4,6 |
Insulation | MgO |
Warranty | 1 Year |
Temperature Range | 200℃-1000℃ |
Accuracy | Class I、II、III |
Outside Dia | 0.5-12.7mm |
Package | Carton. Pallet |
Function | temperature test |
Cable Length | 1-5m or Customized |
Thermocouple Type | K/N/E/J/T/S/R/B |
Brand Name | LEADKIN |
Model Number | LK-K |
Certification | ISO9001, IATF16949, CE |
Place of Origin | NINGBO CHINA |
View Detail Information
Explore similar products
5mm 12.7mm 4 Cores Single Core Shielded Wire External Armoured Cable
4 Core Shielded Mineral Insulated Metal Sheathed Cable 0.25mm 12.7mm SS321
SS446 12.7MM Mineral Insulated Metal Sheathed Cable Type B Thermocouple
Single Phase Armoured Temperature Sensor Theory Welding Cable Sheath SS321 1.5mm
Product Specification
Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 1,000,000M/year |
Delivery Time | 2-7 working days | Packaging Details | 70*70*8cm Carton |
Core | 2,3,4,6 | Insulation | MgO |
Warranty | 1 Year | Temperature Range | 200℃-1000℃ |
Accuracy | Class I、II、III | Outside Dia | 0.5-12.7mm |
Package | Carton. Pallet | Function | temperature test |
Cable Length | 1-5m or Customized | Thermocouple Type | K/N/E/J/T/S/R/B |
Brand Name | LEADKIN | Model Number | LK-K |
Certification | ISO9001, IATF16949, CE | Place of Origin | NINGBO CHINA |
Type: K/N/E/J/T/S/R/B
Place of Origin: Zhejiang, China (Mainland)
Accuracy: I-0.4%t, II-0.75%t, III-1.5%t
Core number: 2,3,4,6
Inorganic mineral insulating lead material: Ni, Cu
Insulator: 99.6% high purity MgO
Certificate:ISO9001, IATF16949, CE
Application: connecting with thermocouple and instrument machine
Sheath material: 0Cr18Ni10Ti, SS304S,SS316L,SS316, Cu
Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0
Product Name | Code | Type | Shaeth Material | Outside Dia. | Temperature |
NiCr-NiSi /NiCr-NiAl | KK | K | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
SS310 Inconel600 | 0.5-1.0 | 500 | |||
1.5-3.2 | 800 | ||||
4.0-6.4 | 900 | ||||
8.0-12.7 | 1000 | ||||
NiCrSi-NiSi | NK | N | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
SS310 Inconel600 | 0.5-1.0 | 500 | |||
1.5-3.2 | 800 | ||||
4.0-6.4 | 900 | ||||
8.0-12.7 | 1000 | ||||
NiCr-Konstantan | EK | E | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
Fe-Konstantan | JK | J | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
Cu-Konstantan | TK | T | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
RhPt10-Ph | SK | S | Inconel600 | 6.0-12.7 | 1100 |
Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.
Type | Class I | Class II | ||
Accuracy | Temp.Range | Accuracy | Temp.Range | |
K | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-1000℃ | ±0.75% | 375℃-1000℃ | |
N | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-1000℃ | ±0.75% | 375℃-1000℃ | |
E | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-800℃ | ±0.75% | 375℃-800℃ | |
J | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-800℃ | ±0.75% | 375℃-800℃ | |
T | ±0.5℃ | -40~125℃ | ±1.0℃ | -40~125℃ |
±0.4% | 125℃-350℃ | ±0.75% | 125℃-350℃ | |
S | 0-1100℃ | ±1.0℃ | 0-1100℃ | ±1.5℃ |
Thermocouple Connections:
MI cables are commonly used to connect thermocouples to temperature measurement devices in applications such as furnaces, kilns, and chemical processing plants.
Instrumentation:
Suitable for connecting various instruments in process control systems, including pressure, flow, and level sensors.
Oil and Gas Industry:
Employed in drilling operations, pipelines, and refineries to monitor temperatures in extreme environments.
Power Generation:
Used in turbines, boilers, and other critical components where precise temperature measurement is essential for safety and efficiency.
HVAC Systems:
Applied in heating, ventilation, and air conditioning systems for accurate temperature monitoring and control.
Installation Considerations:
Bending Radius: MI cables have a specified minimum bending radius that should be adhered to during installation to avoid damaging the insulation.
Termination Techniques: Proper crimping or welding techniques should be used to ensure reliable electrical connections at the thermocouple junctions.
Environmental Factors: Consideration of factors such as temperature, pressure, and chemical exposure is critical during the selection and installation of MI cables.
We add heat shrink tubing and plastic film to make sure high insulated resistance.
Except marking notes, we also have pass card and test report for every coil cable.
We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.
1. Accurate quotation.
2. Confirm the price, trade term, lead time, payment term etc.
3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.
4. Customer arranges the payment for deposit and sends us bank slip.
5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.
6. End Production-Mass production products photos.
7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.
8. The order is finished perfectly when you receive the goods and get satisfied with them .
9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .
1.What are the advantages of using thermocouples?
Wide temperature range.
Fast response time.
Simple and rugged design.
Relatively inexpensive.
Can be used in various environments, including extreme conditions.
2.What are the disadvantages of thermocouples?
Non-linear output, requiring calibration.
Accuracy may be lower than other temperature sensors (like RTDs).
Requires reference junction compensation for precise measurements.
Susceptible to electromagnetic interference.
Company Details
Business Type:
Manufacturer,Importer,Exporter,Seller
Year Established:
2009
Total Annual:
5000000-10000000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd established in 2009 in Ningbo City. It has a plant area of 17000 square meters and a total staff of 100 employees now. Ningbo Leadkin is a Chinese leading manufacture on instrument, electric equipment and armound cable. Ningb... Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd established in 2009 in Ningbo City. It has a plant area of 17000 square meters and a total staff of 100 employees now. Ningbo Leadkin is a Chinese leading manufacture on instrument, electric equipment and armound cable. Ningb...
Get in touch with us
Leave a Message, we will call you back quickly!