China factories

China factory - Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.

Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.

  • China ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature
China Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature

  1. China Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature
  2. China Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature

Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature

  1. MOQ: 50M
  2. Price: USD 0.5-6.8/M
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1,000,000M/year
Delivery Time 2-7 working days
Packaging Details 70*70*8cm Carton
Insulation MgO
Warranty 1 Year
Temperature Range -200℃-1300℃
Accuracy Class I、II、III
Outside Dia 0.5-12.7mm
Package Carton. Pallet
Function temperature test
Theory Temperature Sensor
Cable Length 1-5m or Customized
Core Single/double
Thermocouple Type K/N/E/J/T/S/R/B
Brand Name LEADKIN
Model Number LK-K
Certification ISO9001, IATF16949, CE
Place of Origin NINGBO CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 1,000,000M/year
Delivery Time 2-7 working days Packaging Details 70*70*8cm Carton
Insulation MgO Warranty 1 Year
Temperature Range -200℃-1300℃ Accuracy Class I、II、III
Outside Dia 0.5-12.7mm Package Carton. Pallet
Function temperature test Theory Temperature Sensor
Cable Length 1-5m or Customized Core Single/double
Thermocouple Type K/N/E/J/T/S/R/B Brand Name LEADKIN
Model Number LK-K Certification ISO9001, IATF16949, CE
Place of Origin NINGBO CHINA
High Light Accurate Temperature Measurement Thermocouple CableMineral Insulated Thermocouple CableInsulation MgO Thermocouple Cable

Quick Details:

 Type: K/N/E/J/T/S/R/B

Place of Origin: Zhejiang, China (Mainland)

Accuracy: I-0.4%t, II-0.75%t, III-1.5%t

Core number: Single / Double

Insulator: 99.6% high purity MgO

Certificate:ISO9001, IATF16949, CE

Application: connecting with thermocouple and instrument machine

Conductor material: NiCr-NiSi, NiCrSi-NiSi, NiCr-Konstantan, Fe-Konstantan, Cu-Konstantan

Sheath material: Inconel600, 0Cr18Ni10Ti, SS304S,SS316L, SS310,SS316,GH3030, GH3039, GH747

Sheath Dia(mm): 0.5mm to 12.7mm :φ0.5,φ1.0, φ1.5(1.6), φ2.0, φ3.0(3.2),φ4.0,φ5.0(4.8),φ6.0(6.4),φ8.0,φ12.7

 

 

Type for Sheath Wire Type K:

Product Name Code Type Shaeth Material Outside Dia. Temperature
NiCr-NiSi /NiCr-NiAl KK K SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000
NiCrSi-NiSi NK N SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000
NiCr-Konstantan EK E SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
Fe-Konstantan JK J SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
Cu-Konstantan TK T SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
RhPt10-Ph SK S Inconel600 6.0-12.7 1100

 

Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.

 

Accuracy for Sheath Wire Type K

Type Class I Class II
Accuracy Temp.Range Accuracy Temp.Range
K ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-1000℃ ±0.75% 375℃-1000℃
N ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-1000℃ ±0.75% 375℃-1000℃
E ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-800℃ ±0.75% 375℃-800℃
J ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-800℃ ±0.75% 375℃-800℃
T ±0.5℃ -40~125℃ ±1.0℃ -40~125℃
±0.4% 125℃-350℃ ±0.75% 125℃-350℃
S 0-1100℃ ±1.0℃ 0-1100℃ ±1.5℃

 

About this product:

Construction and Installation

Material: The choice of materials affects the thermocouple's temperature range, sensitivity, and resistance to environmental factors.

Insulation: Thermocouples can be insulated with ceramic, glass, or plastic materials to protect against contamination and physical damage.

Wiring: Proper wiring techniques are crucial to avoid introducing errors due to electromagnetic interference or thermal gradients.

Calibration and Accuracy

Calibration: Thermocouples need to be calibrated against known temperature standards to ensure accuracy. Calibration can be done using ice baths, temperature blocks, or other reference sources.

Accuracy Factors: Errors can arise from non-linearities, reference junction temperature variations, and the quality of the thermocouple wire.

Reference Junction Compensation.

Cold Junction Compensation: Since the thermoelectric voltage depends on the temperature difference, the temperature of the reference junction must be known or compensated for. This is typically done using electronic circuitry that measures the reference junction temperature.

Applications :

  • Solid waste incinerators
  • Sintering powdered metals
  • Firing ceramic materials
  • Gas or oil fired furnaces
  • Fuel fired heat exchangers
  • Box furnaces
  • Nuclear or hydrocarbon based energy plants
  • And many more...

 

 

Product Pictures

 

 

 

 

Company Information:

A. Main Products

 

 

 

B. Package

 

We add heat shrink tubing and plastic film to make sure high insulated resistance.

Except marking notes, we also have pass card and test report for every coil cable.

 

 

C. Mi cable Production line

We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.

 

 

 

Order Notice:

1. Accurate quotation.

2. Confirm the price, trade term, lead time, payment term etc.

3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.

4. Customer arranges the payment for deposit and sends us bank slip.

5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.

6. End Production-Mass production products photos.

7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.

8. The order is finished perfectly when you receive the goods and get satisfied with them .

9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Seller

  • Year Established:

    2009

  • Total Annual:

    5000000-10000000

  • Employee Number:

    100~200

  • Ecer Certification:

    Verified Supplier

Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd established in 2009 in Ningbo City. It has a plant area of 17000 square meters and a total staff of 100 employees now.   Ningbo Leadkin is a Chinese leading manufacture on instrument, electric equipment and armound cable. Ningb... Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd established in 2009 in Ningbo City. It has a plant area of 17000 square meters and a total staff of 100 employees now.   Ningbo Leadkin is a Chinese leading manufacture on instrument, electric equipment and armound cable. Ningb...

+ Read More

Get in touch with us

  • Reach Us
  • Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
  • No.888 DONGMIN ROAD ZHUANGSHI STREET, ZHENHAI DISTRICT NINGBOCITY ZHEJIANG PROVINCE, CHINA
  • https://www.leadkin.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement