Payment Terms | T/T, L/C, Western Union |
Supply Ability | 6000 units per month |
Delivery Time | 3-7 working days |
Packaging Details | Standard Package |
Output Frequenc: | 0-320Hz, 50/60Hz |
Size: | 89*190*135(mm) |
weight | 1.4kg |
IGBT and DSP brand: | Fuji and TI's latest DSP |
Adjusting speed range | 1:100 (V/F control); 1:200 (SVC1, SVC2); 1:1000 (Vector control) |
Control technique: | V/F, MPPT, SVC1, SVC2, frequency inverter |
Overload capacity: | 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s |
Applicable motors: | solar pump, pmsm, Asynchronous motor and synchronous motor |
Brand Name | ZK/ZUN |
Model Number | SU10M-D2-2R2G-B |
Certification | ISO CE |
Place of Origin | Shenzhen China |
View Detail Information
Explore similar products
SKD IP20 IP54 IP65 MPPT solar pump VFD solar water pump inverter
380V 7.5KW 10HP 16A 99% Efficiency MPPT VFD Solar Pump Inverter
0.75KW 1.5KW 2.2KW 3HP DC Drive MPPT Solar VFD Solar Pump Inverter
220V 7.5KW 10HP 32A MPPT Solar Water Pump Inverter
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 6000 units per month |
Delivery Time | 3-7 working days | Packaging Details | Standard Package |
Output Frequenc: | 0-320Hz, 50/60Hz | Size: | 89*190*135(mm) |
weight | 1.4kg | IGBT and DSP brand: | Fuji and TI's latest DSP |
Adjusting speed range | 1:100 (V/F control); 1:200 (SVC1, SVC2); 1:1000 (Vector control) | Control technique: | V/F, MPPT, SVC1, SVC2, frequency inverter |
Overload capacity: | 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s | Applicable motors: | solar pump, pmsm, Asynchronous motor and synchronous motor |
Brand Name | ZK/ZUN | Model Number | SU10M-D2-2R2G-B |
Certification | ISO CE | Place of Origin | Shenzhen China |
High Light | 2.2kw Solar VFD Pump Drive 450VDC ,1.4kg Solar VFD Pump Drive 220VAC ,450VDC VFD Solar Pump Controller |
ZK/ZUN Solar VFD 0.75kw 2.2kw 450VDC 220VAC LED Keypad MPPT Vfd Solar Pump Inverter
SU10M-D2-2R2G-B mini size 2.2kw solar pump inverter
Quick Details:
1.Adopt advanced MPPT technology to give full play to the power generation efficiency of the solar cell array;
2.Automatically adjust the motor speed and the water output of the water pump according to the change of sunlight intensity;
3.The inverter automatically sleeps when the water level of the reservoir is high, and restarts automatically when the water level is low, realizing automatic water level control;
4.It can prevent the water pump from dry pumping without water when the water source is dry;
5.When the light is weak (such as the sun sets), it will automatically sleep, and when the light becomes strong (such as sunrise), it will exit the sleep;
Features:
1.Energy saving and environmental protection
2.Plastic shell and sheet metal shell design
Item | Specification | |
Power input | Voltage, frequency | DI: 70V DC to 400V DC or 110V±15% AC, 50/60Hz S |
D2: 150V DC to 450V DC or 220V±15% AC, 50/60Hz; | ||
D3: 350V DC to 750V DC or 380V±15% AC, 50/60Hz | ||
Allowable fluctuations | voltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2 required | |
Power factor | ≥0.94(with DC reactor) | |
Mppt Efficiency | ≥99.6% | |
Output | Output voltage | Output under rated condition: 3 phase, 0~input voltage, inaccuracy<5% |
Output frequency range | G type:0~600Hz | |
Output frequency accuracy | Max frequency ±0.5% | |
Overload capacity | G type: 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s | |
Motor control mode | V/F without PG , VC without PG , VC with PG | |
Product basic functions | Acceleration/Deceleration curve | 2 modes: linear Acceleration/Deceleration and S curve Acceleration/Deceleration. |
4 sets of ACC/DEC, time unit 0.01s selectable, longest time: 650.00s. | ||
Rated output voltage | Rely on power supply voltage compensate function, while motor rated voltage is 100%, set it at the range of 50-100%(output can not over input voltage). | |
Voltage auto-adjustment | While power supply voltage fluctuates, it can auto-keep constant output voltage. | |
Auto energy-saving running | While under V/F control mode, according to load situation, auto-optimize output voltage to save energy. | |
Standard functions | PID control, speed track, power off restart, jump frequency, upper/lower frequency limit control, program operation, multi- speed, RS485, analog output, frequency impulse output. | |
Frequency setting channels | Keyboard digital setting, keyboard potentiometer ,Analog voltage/current terminal AI1,AI2, Communication given and multi-channel terminal selection, Main and auxiliary channel combination, expansion card, supporting different modes switch. | |
Feedback input channel | Voltage/Current Terminal AI1, Voltage/Current Terminal AI12, Communication | |
given, pulse input X5. | ||
Running command channel | Operation panel given,external terminal given, communication given, expansion card given. | |
Input command signal | Start, stop, FWD/REV, JOG, multi-step speed, reset, ACC/DEC time selection, frequency given channel selection, exterior fault alarm. | |
Protective function | Overvoltage, under-voltage, current limit, over-current, overload, electric thermal relay, overheat, overvoltage stall, data protection, rapid speed protection, input/output phase failure protection. | |
Environment | Install place | altitude ≤ 1000m,above 1000m down the rated amount, each increase of 100m down the rated mount of 1%;no condensation, ice ,rain, snow, hail; solar radiation below 700W/㎡, air pressure 70-106 kPa. |
Temperature, humidity | -10 ~ + 50 ℃, derating above 40 ℃, maximum temperature 60 ℃ (no-load operation)5% to 95% RH (non-condensing) | |
Vibration | When 9~200Hz, 5.9m/s2(0.6g) | |
Storage temperature | -30 ~+60℃ | |
Protection grade | IP20 | |
Cooling method | Forced air cooling |
Model List:
MODELS | Rate current (A) | Applicable for pumps | Input Voltage Range DC (V) | Output voltage VAC |
General type D1:90V DC to 400V DC or 110V±15% AC Input, 50/60Hz, 3 Phase 0-110Vac ouptut | ||||
SU10M-D1-R75G-B | 7A | 0.75kw | 70-400V | 0-110V |
SU10M-D1-1R5G-B | 10A | 1.5kw | 70-400V | 0-110V |
General type: D2:150V DC to 450V DC or 220V±15% AC Input, 50/60Hz, 3 Phase 0-220Vac ouptut | ||||
SU10M-D2-R75G-B | 4A | 0.75kw | 150-450V | 0-220V |
SU10M-D2-1R5G-B | 7A | 1.5kw | 150-450V | 0-220V |
SU10M-D2-2R2G-B | 10A | 2.2kw | 150-450V | 0-220V |
SU10M-D2-004G-B | 16A | 4.0kw | 150-450V | 0-220V |
General type: D3:250V DC to 800V DC or 380V±15% AC input, 50/60Hz, 3 Phase 0-380V/440Vac ouptut | ||||
SU100-D3-R75G-B | 3A | 0.75kw | 250-800V | 0-380V/440V |
SU100-D3-1R5G-B | 4A | 1.5kw | 250-800V | 0-380V/440V |
SU100-D3-2R2G-B | 6A | 2.2kw | 250-800V | 0-380V/440V |
SU100-D3-004G-B | 9.2A | 4.0kw | 250-800V | 0-380V/440V |
SU100-D3-5R5G-B | 13A | 5.5kw | 250-800V | 0-380V/440V |
SU100-D3-7R5G-B | 17A | 7.5kw | 250-800V | 0-380V/440V |
SU100-D3-011G-B | 25A | 11kw | 250-800V | 0-380V/440V |
SU100-D3-015G-B | 32A | 15kw | 250-800V | 0-380V/440V |
SU100-D3-018G-B | 37A | 18.5kw | 250-800V | 0-380V/440V |
SU100-D3-022G-B | 45A | 22kw | 250-800V | 0-380V/440V |
SU100-D3-030G | 60A | 30kw | 250-800V | 0-380V/440V |
SU100-D3-037G | 75A | 37kw | 350-800V | 0-380V/440V |
SU100-D3-045G | 90A | 45kw | 350-800V | 0-380V/440V |
SU100-D3-055G | 112A | 55kw | 350-800V | 0-380V/440V |
SU100-D3-075G | 150A | 75kw | 350-800V | 0-380V/440V |
Inverter model | Dimensions(mm) | Installation(mm) | Mounting aperture | |||||
W | H | D | D1 | W1 | H1 | |||
SU100-D1-R75G-B | 89 | 190 | 135 | 144 | 79 | 180 | M4×2 | |
SU100-D2-R75G-B | ||||||||
SU100-D2-1R5G-B | ||||||||
SU100-D3-R75G-B | ||||||||
SU100-D3-1R5G-B | ||||||||
SU100-D3-2R2G-B | ||||||||
SU100-D1-1R5G-B | 106 | 230 | 148 | 157 | 96 | 219 | M4×3 | |
SU100-D2-2R2G-B | ||||||||
SU100-D2-004G-B | ||||||||
SU100-D3-004G-B | ||||||||
SU100-D3-5R5G-B | ||||||||
SU100-D3-7R5G-B | ||||||||
SU100-D3-011G-B | 130 | 275 | 160 | 169 | 115 | 260 | M5×3 | |
SU100-D3-015G-B | ||||||||
SU100-D3-018G-B | 155 | 335 | 191 | 200 | 141.5 | 320 | M5×4 | |
SU100-D3-022G-B |
---FAQ---
Q1 : What's the different between inverter and solar inverter?
Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accpet DC input, it more save power.
Q2: What should be noticed when installing inverter?
Put the product in a place where is well ventilate,cool, dry and water-proof. Do not stress or put foreign objects into the inverter. Remember to turn on the inverter before turn on the appliance.
Q3:What is the payment terms?
100% T/T in advance for sample order. 30% T/T in advance, banlance 70% T/T before delivery for bulk order.
Q4:What is your main market?
Our brands are well known in Europe, Africa, Middle East, Southeast Asia and South America.
Q5 : How about the delivery time?
3-5 days for sample order;15-25 days for bulk order.
Q6:What is the supply capacity of your factory?
The monthly output of inverters is over 6,000 units.
For regular orders, we can deliver to you in 5-24 days.
Company Details
Business Type:
Manufacturer
Year Established:
2016
Total Annual:
3Million-5Million
Employee Number:
200~500
Ecer Certification:
Verified Supplier
Shenzhen ZK Electric Technology Co., Ltd. (here called ZK) is a professional manufacturer of kinds of solar pump inverter, AC drives, variable frequency inverter and soft start, etc. We are not only focus on designing, manufacturing, sales and after sales service for above mentioned products, ... Shenzhen ZK Electric Technology Co., Ltd. (here called ZK) is a professional manufacturer of kinds of solar pump inverter, AC drives, variable frequency inverter and soft start, etc. We are not only focus on designing, manufacturing, sales and after sales service for above mentioned products, ...
Get in touch with us
Leave a Message, we will call you back quickly!