Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 2200 |
Delivery Time | 5-8 days |
Packaging Details | Palletized |
Response Time (T90) | ≤ 30 seconds |
Recovery Time (T10) | ≤ 60 seconds |
Zero Drift | ≤ ±0.05 ppm/Month |
Span Drift | ≤ ±3% Full Scale/Year |
Operating Temperature Range | -10℃~50℃ |
Operating Humidity Range | 15%~90% RH |
Brand Name | YJJ |
Model Number | NE4-HCHO-S |
Place of Origin | Japan |
View Detail Information
Explore similar products
H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 2200 |
Delivery Time | 5-8 days | Packaging Details | Palletized |
Response Time (T90) | ≤ 30 seconds | Recovery Time (T10) | ≤ 60 seconds |
Zero Drift | ≤ ±0.05 ppm/Month | Span Drift | ≤ ±3% Full Scale/Year |
Operating Temperature Range | -10℃~50℃ | Operating Humidity Range | 15%~90% RH |
Brand Name | YJJ | Model Number | NE4-HCHO-S |
Place of Origin | Japan | ||
High Light | electrochemical formaldehyde gas sensor ,YJJ NE4-HCHO-S gas sensor ,formaldehyde sensor with warranty |
Product Description:
YJJ NE4-HCHO-S Type Electrochemical Formaldehyde Gas Sensor
Features:
NE4-HCHO-S electrochemical formaldehyde gas sensor is specifically designed for precise detection of formaldehyde. With its unique parameter performance, it plays a crucial role in various fields. The following will detail its various parameters and their corresponding uses.
Detection range: 0 - 10 ppm. This range is set to meet the needs of indoor air quality monitoring and the detection of low-concentration formaldehyde in most industrial scenarios. In indoor environments such as homes, offices, and schools, the formaldehyde concentration safety standard is usually in a relatively low range. This detection range is sufficient to accurately detect whether formaldehyde exceeds the standard and ensure the health of people. For example, in newly renovated houses, due to the release of formaldehyde from decoration materials, the sensor can continuously monitor within this range, providing reliable data for residents to determine when it is suitable to move in. In some industrial production processes with strict restrictions on the use or emission of formaldehyde, such as wood panel processing and certain chemical product manufacturing, it can also effectively monitor the formaldehyde concentration, ensuring that the production process complies with environmental protection and safety regulations.
Maximum overload: 50 ppm. This indicates the highest formaldehyde concentration that the sensor can withstand. This parameter ensures that the sensor will not be damaged due to a sudden high concentration shock in environments where the formaldehyde concentration temporarily rises abnormally, maintaining normal operation and measurement accuracy. For example, at an emergency site for formaldehyde leakage handling, the formaldehyde concentration in a certain area may spike temporarily, and the sensor can tolerate this for a certain period of time, providing valuable concentration data support for rescue and subsequent handling.
Sensitivity: 500 ± 150 nA/ppm. The sensitivity is extremely high, meaning it can respond to very small changes in formaldehyde concentration. Even if the formaldehyde concentration in the environment only has a slight fluctuation, it can precisely reflect through the current change, thereby achieving high-precision detection of low-concentration formaldehyde. In places with strict air quality requirements such as hospitals and kindergartens, it can promptly detect the subtle changes in formaldehyde concentration and take measures in advance to avoid harm to sensitive populations.
Specifications:
Parameter | Specification |
Model Number | NE4-HCHO-S |
Sensor Type | Electrochemical Formaldehyde (HCHO) Gas Sensor (for specific detection of formaldehyde) |
Target Gas | Formaldehyde (HCHO) |
Detection Range | Typically 0~10 ppm (adjustable or customizable per application requirements; confirm with actual product) |
Resolution | ≤ 0.01 ppm (minimum detectable concentration change) |
Accuracy | ±5% Full Scale (FS) or ±0.1 ppm (whichever is larger) at 25℃ ±2℃, 50%±10% RH |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...