Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 5000pcs |
Delivery Time | 3-5work days |
Packaging Details | Paper box |
Range of measurement | 0.3~1.0;1.0~2.5;2.5~10 |
Counting Efficiency | 50%@0.3μm 98%@>=0.5μm |
Effective Range(PM2.5 standard) | 0~500 |
Maximum Range(PM2.5 standard)* | ≥1000 |
Resolution | 1 |
Standard Volume | Standard Volume |
Model Number | PMS7003 PMS7003M PMS5003 |
Place of Origin | Japan |
View Detail Information
Explore similar products
YJJ ME300BF EPK-I 5000 Endoscope Cold Light Source Bulb Y1911 CERMAX VQ Pentax
YJJ 012-63000 Excelitas Fluorescence Microscope Bulb X-Cite 120 Series Mercury
LRM-274-HFIK-12 Quad Channel Pyroelectric Detector Thermal Compensation
LLC102000 Compact Liquid Sensors For Harsh Environments Threaded Mount 2.5 MA
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 5000pcs |
Delivery Time | 3-5work days | Packaging Details | Paper box |
Range of measurement | 0.3~1.0;1.0~2.5;2.5~10 | Counting Efficiency | 50%@0.3μm 98%@>=0.5μm |
Effective Range(PM2.5 standard) | 0~500 | Maximum Range(PM2.5 standard)* | ≥1000 |
Resolution | 1 | Standard Volume | Standard Volume |
Model Number | PMS7003 PMS7003M PMS5003 | Place of Origin | Japan |
High Light | PMS7003 Particle Concentration Sensor ,PMS5003 Particle Concentration Sensor ,Digital Particle Concentration Sensor |
PMS7003 PMS7003M PMS5003 Digital universal particle concentration sensor
PMS7003:
Main characteristics:
Zero false alarm rate
Real-time response
Correct data
Minimum distinguishable particle diameter :0.3 micrometer
High anti-interference performance because of the patent structure of six sides shielding
Optional direction of air inlet and outlet in order to adapt the different design
Very Slim
Overview:
PMS7003 is a kind of digital and universal particle concentration sensor, which can be used to obtain the number of suspended particles in the air, i.e. the concentration of particles, and output them in the form of digital interface. This sensor can be inserted into variable instruments related to the concentration of suspended particles in the air or other environmental improvement equipments to provide correct concentration data in time.
Working principle:
Laser scattering principle is used for such sensor, i.e. produce scattering by using laser to radiate suspending particles in the air, then collect scattering light in a certain degree, and finally obtain the curve of scattering light change with time. In the end, equivalent particle diameter and the number of particles with different diameter per unit volume can be calculated by microprocessor based on MIE theory. Please find the functional diagram of each part of sensor from Figure 1 as follows.
Interface Level | L <0.8 @3.3 H >2.7@3.3 |
Working Temperature Range | -10~+60 |
Working Humidity Range | 0~99% |
Storage Temperature Range | -40~+80 |
MTTF | ≥3 |
Physical Size | 48×37×12 |
PMS5003:
Main characteristics:
Zero false alarm rate
Real-time response
Correct data
Minimum distinguishable particle diameter :0.3 micrometer
High anti-interference performance because of the patent structure of six sides shielding
Optional direction of air inlet and outlet in order to adapt the different design
Overview:
PMS5003 is a kind of digital and universal particle concentration sensor, which can be used to obtain the number of suspended particles in the air, i.e. the concentration of particles, and output them in the form of digital interface. This sensor can be inserted into variable instruments related to the concentration of suspended particles in the air or other environmental improvement equipments to provide correct concentration data in time.
Working principle:
Laser scattering principle is used for such sensor, i.e. produce scattering by using laser to radiate suspending particles in the air, then collect scattering light in a certain degree, and finally obtain the curve of scattering light change with time. In the end, equivalent particle diameter and the number of particles with different diameter per unit volume can be calculated by microprocessor based on MIE theory. Please find the functional diagram of each part of sensor from Figure 1 as follows.
Range of measurement | 0.3~1.0;1.0~2.5;2.5~10 |
Counting Efficiency | 50%@0.3μm 98%@>=0.5μm |
Effective Range(PM2.5 standard) | 0~500 |
Maximum Range(PM2.5 standard)* | ≥1000 |
Resolution | 1 |
Single Response Time | <1 |
Total Response Time | ≤10 |
Active Current | ≤100 |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...
Get in touch with us
Leave a Message, we will call you back quickly!