Payment Terms | L/C, D/A, D/P, T/T |
Packaging Details | Carton |
Brand | GE Mac1200ST ECG Machine Printer Assembly |
Color | white |
Category | Printer Assembly |
Wattanty | 90 Days |
Packing weight | 0.45kg |
size | standard |
Application area | electrocardiograph |
Condition | Used-Good |
Estimated Ship Time | 3-5 Business Days |
Production Capacity | 1000 Pieces |
Specification | 15*8 *8cm |
Used for | GE Mac1200ST electrocardiograph |
net weight | 0.23kg |
Shape | Product Standards |
Brand Name | GE |
Model Number | GE Mac1200ST ECG Machine Printer Assembly |
Certification | CE/CB/ROSH |
View Detail Information
Explore similar products
3 Lead W Grab ECG Machine Parts Multi Link Ge Ecg Leads Assy AHA.306M 12FT
Universal Mixed Length 10m ECG Machine Parts 420101-002 Ge Ecg Cable
6 Pin 5 / Lead Ecg Lead Wires , EA6151B Button Type Defibrillator Accessories
7.4V 2300mA Patient Monitor Accessories , Mindray T1 LI12I001A Ecg Machine
Product Specification
Payment Terms | L/C, D/A, D/P, T/T | Packaging Details | Carton |
Brand | GE Mac1200ST ECG Machine Printer Assembly | Color | white |
Category | Printer Assembly | Wattanty | 90 Days |
Packing weight | 0.45kg | size | standard |
Application area | electrocardiograph | Condition | Used-Good |
Estimated Ship Time | 3-5 Business Days | Production Capacity | 1000 Pieces |
Specification | 15*8 *8cm | Used for | GE Mac1200ST electrocardiograph |
net weight | 0.23kg | Shape | Product Standards |
Brand Name | GE | Model Number | GE Mac1200ST ECG Machine Printer Assembly |
Certification | CE/CB/ROSH |
Printing components of electrocardiograph, including machine cover, cutter, thermal sensor, casing, thermal paper roll, anti-side roll 1, motor, thermal printing device, anti-side roll 2, frame, shaft side mechanism, work indicator light , chute and control panel mechanism, the cover is connected to the rear edge of the housing through a circlip. With the cutting knife of this utility model, the blade is installed in the chute through the slider. By pulling the pull ring to drive the blade to move, the ECG drawing can be accurately cut, which avoids the inability to correct the ECG drawing due to uneven tearing by hand or the ECG being torn. The problem of accurately judging the condition of the disease. The setting of the thermostat is conducive to constant temperature control of the thermal printer core to avoid the problem of lines that are too thick due to excessive temperature or too thin due to low temperature. Anti-side roll one and anti-side roll two The setting effectively prevents the thermal paper from rolling on its side when printing out. An electrocardiograph is a common medical instrument used to detect and record patients' electrocardiogram signals. Correctly installing the printing paper is an important step in using the electrocardiograph.
It is characterized in that one side of the base frame is provided with a chute with an upward opening, one end of the wrench is rotatably arranged with one side of the base frame, and the other end is a free end. A slot is formed on the inside of the wrench, and the slot has a third locking position and a second locking position. The sliding portion extends laterally from one side of the printhead bracket. The sliding part is located in the chute, and the outer end is stuck in the groove. The patented technology of the present invention also discloses a thermal printing core. When loading printing paper or correcting processing, just pull the wrench slightly, and the print head bracket will open with the rubber roller. After processing is completed, the wrench will return to its original shape and the print head bracket will be close to the rubber roller. The overall structure is simple and the operation is convenient and quick.
Item name | GE Mac1200ST ECG Machine Printer Assembly |
Brand | GE |
Model | printer assembly |
Use place | Hospital Devices; Medical Care; ICU; |
Deliver time | 3-5 days |
Warranty | 90 days |
Power supply standards | Comply with international electricity standards |
Assembly | Cover, cutter, thermal sensor, casing |
We default to express delivery by DHL. We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.
If you have any questions about the GE Mac1200ST electrocardiograph printer assembly , please call or email us .
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!