Product Name | PHiliph EPiQ Series Ultrasound X5-1 XMATRIX Array Transducer Probe |
Technology | xMATRIX, PureWave |
Frequency range | 5-1 MHz |
Aperture | Proprietary |
Volume of field of view | 98° x 98° |
Applications | Adult/Pediatric Cardiac, Abdominal Vascular, TCD |
Image Fusion Navigation capable | No |
Array Type | Sector, Volume Sector |
Field of view | 90° |
Modes | 2D, M-Mode, Color M-Mode, PW, CW, Color, TDI, TDI PWD, xPlane, Live 3D, Live 3D Color, Harmonic Imaging, Advanced XRES, 2D/Live 3D LVO, iRotate and xPLANE |
Biopsy capable | No |
Physical dimensions | 9.2 x 3.9 x 2.9 cm (3.6 x1.5 x 1.1 in) LWD |
View Detail Information
Explore similar products
Medison NEV4-9ES Ultrasound Transducer Probe For Medison Accuvix V10, SonoAce X8
GE 11L Linear Array Ultrasound Transducer Probe Used And Good White Metal
SuperSonic Ultrasound Machine Linear Vascular Probe SL18-5 Super Linear Array
PHiliph Affiniti 50G/CX30 Ultrasound Machine C6-2 Convex Array Probe Ultrasonic
Product Specification
Product Name | PHiliph EPiQ Series Ultrasound X5-1 XMATRIX Array Transducer Probe | Technology | xMATRIX, PureWave |
Frequency range | 5-1 MHz | Aperture | Proprietary |
Volume of field of view | 98° x 98° | Applications | Adult/Pediatric Cardiac, Abdominal Vascular, TCD |
Image Fusion Navigation capable | No | Array Type | Sector, Volume Sector |
Field of view | 90° | Modes | 2D, M-Mode, Color M-Mode, PW, CW, Color, TDI, TDI PWD, xPlane, Live 3D, Live 3D Color, Harmonic Imaging, Advanced XRES, 2D/Live 3D LVO, iRotate and xPLANE |
Biopsy capable | No | Physical dimensions | 9.2 x 3.9 x 2.9 cm (3.6 x1.5 x 1.1 in) LWD |
High Light | Ultrasound Array Transducer Probe ,PHiliph EPiQ Ultrasound Array Transducer Probe |
Product Name | PHiliphh EPiQ Series Ultrasound transducer probe X5-1 xMATRIX array
|
Technology | xMATRIX, PureWave |
Frequency range | 5-1 MHz |
Aperture | Proprietary |
Volume of field of view | 98° x 98° |
Applications | Adult/Pediatric Cardiac, Abdominal Vascular, TCD |
Image Fusion Navigation capable | No |
Array Type | Sector, Volume Sector |
Field of view | 90° |
Modes | 2D, M-Mode, Color M-Mode, PW, CW, Color, TDI, TDI PWD, xPlane, Live 3D, Live 3D Color, Harmonic Imaging, Advanced XRES, 2D/Live 3D LVO, iRotate and xPLANE |
Biopsy capable | No |
Physical dimensions | 9.2 x 3.9 x 2.9 cm (3.6 x1.5 x 1.1 in) LWD |
Warnings and Precautions
For maximum safety when using detergents and disinfectants, observe the following warnings and precautions:
be careful
Not all disinfectants are effective against all types of contamination. Ensure that the type of disinfectant is appropriate for the intended system or transducer and that the solution concentration and contact time are appropriate for the intended clinical use.
Warnings
Disinfectants are recommended based on their chemical compatibility with the product materials and not their biological effectiveness. For information on the bioavailability of disinfectants, refer to the U.S. Food and Drug Administration and U.S. Food and Drug Administration disinfectant manufacturer guidelines and recommendations. Centers for Disease Control.
Warnings
If you use a pre-mixed solution, be sure to check the expiration date printed on the solution.
Warnings
The level of disinfection required for a device depends on the type of tissue it comes in contact with during use and the type of transducer used. Make sure the type of disinfectant is appropriate for the transducer type and transducer application.
Warnings
Using non-recommended disinfectants, using incorrect solution concentrations, or immersing the transducer deeper or longer than recommended can damage or discolor the transducer and void the transducer warranty.
Cautions
Limit the use of isopropyl alcohol (rubbing alcohol), denatured alcohol, and alcohol-based products on all transducers. For transducers with USB connectors, only the transducer body and lens (acoustic window) can be cleaned with alcohol. For non-TEE converters, only the connector housing and the converter housing and lens can be cleaned with alcohol. For the TEE sensor, the only parts that can be cleaned with alcohol are the connector housing and the control housing. Make sure the solution is only 91% or less isopropanol or 85% or less denatured ethanol. Do not use alcohol to clean any other part of the transducer (including the cable, USB connector, or strain relief) as this may damage those parts of the transducer. This damage is not covered by the warranty or your service contract.
Thank you so much for attention .If you're interested in PHiliphh EPiQ Series Ultrasound X5-1 XMATRIX Array Transducer Probe ,feel free to contact us .Thank you .
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!