Payment Terms | T/T, Western Union,PayPal |
Delivery Time | 3-5 working days |
Product name | Goldway |
Type | UT4000A UT4000B UT4000C UT4000F |
Product Name | NIBP board |
Warranty | 90days |
Repeat Cycles | 1~10, 15, 30, 60, 90, 120 minutes |
Deflation Pressure | 30mmHg(4.0kPa) higher than the last systolic pressure. |
Cuff Inflation Rate | No greater than 50mmHg/sec |
Mode of transport | Express delivery |
Minimum purchase | 1pcs |
Pressure Display Accuracy | ± 3mmHg |
Brand Name | Goldway |
Model Number | UT4000A UT4000B UT4000C UT4000F |
View Detail Information
Explore similar products
Patient Monitor Accessories Goldway UT4000 Monitor Blood Pressure Plate Great
Mindray PM7000 Patient Monitor Accessories Keyboard Silicone 7000-20-24395
Well-chosen Patient Monitor Mainboard Goldway G30 40 60 70 80 UT4000B UT6000
Patient Monitor Repair Parts GE Dash4000 Patient Monitor Flat Cable in ready
Product Specification
Payment Terms | T/T, Western Union,PayPal | Delivery Time | 3-5 working days |
Product name | Goldway | Type | UT4000A UT4000B UT4000C UT4000F |
Product Name | NIBP board | Warranty | 90days |
Repeat Cycles | 1~10, 15, 30, 60, 90, 120 minutes | Deflation Pressure | 30mmHg(4.0kPa) higher than the last systolic pressure. |
Cuff Inflation Rate | No greater than 50mmHg/sec | Mode of transport | Express delivery |
Minimum purchase | 1pcs | Pressure Display Accuracy | ± 3mmHg |
Brand Name | Goldway | Model Number | UT4000A UT4000B UT4000C UT4000F |
High Light | UT4000F Patient Monitor NIBP Board ,GW4F5S01C Patient Monitor NIBP Board ,UT4000B Bed Side Monitor Parts |
Goldway UT4000A UT4000B UT4000C UT4000F patient monitor NIBP board GW4F5S01C
► Brief Introduction
Processing the NIBP
Pressure data is converted to digital format and conveyed to the processor. The NIBP pump uses an oscillometric method that drives stepwise pressure deflation. Pump software eliminates most ambient noise and motion interference. It can be applied to neonatal, pediatric and adult patients. The blood pressure range for Systolic is 30-254 mmHg and Diastolic 10-220 mmHg. Accuracy is Maximum Mean Error ±5 mmHg, with Maximum Standard Deviation no greater than 8 mmHg.
NIBP processing uses an oscillometric technique to provide needed measurements at selected intervals. This technique uses an inflatable sPHiliphhilipygmomanometer cuff similar to those used by clinicians in routine measurements. A motorized pump inflates the cuff to approximately 170 mmHg (adult mode) initially, at which point the pressure effectively stops the flow of blood. Then, under monitor control, the pressure in the cuff is gradually reduced, while a pressure transducer detects the pressure and transmits the parameter signal to the NIBP input circuitry. As the pressure is reduced, blood flows in the previously occluded artery, and changes the measurements made by the transducer. The point at which oscillation increases sharply is defined as systolic pressure. As the cuff continues to deflate, the oscillation amplitude increases to a maximum, and then decreases. The peak oscillation amplitude is defined as the mean arterial pressure. The point at which the system detects a rapid decrease in oscillation is defined as the diastolic pressure.
► The NIBP assembly and circuitry contain the following elements:
• Pump
• Valves
• Manifold
• Filter
• Pressure measurement and control circuitry
► Non-Invasive Blood Pressure(NIBP)
Method | Automatic Oscillometric | |
Parameters | Systolic, diastolic, mean arterial pressure, pulse | |
Scale | mmHg or Kpa | |
Operating Modes | Manual, Automatic, Continuous | |
Repeat Cycles | 1~10, 15, 30, 60, 90, 120 minutes | |
Measure Range | Systolic | Adult/Pediatric 30 ~ 254mmHg (4.0 ~ 33.9kPa) |
Neomate 30 ~ 135mmHg (4.0 ~ 18.0kPa) | ||
Diastolic | Adult/Pediatric 10 ~ 220mmHg (1.3 ~ 29.3kPa) | |
Neomate 10 ~ 110mmHg (1.3 ~ 14.7kPa) | ||
Cuff Pressure Range | Adult/Pediatric 0 ~ 280mmHg (0 ~ 37.3kPa) | |
Neonate 0 ~ 140mmHg (0 ~ 18.7kPa) | ||
Initial Cuff Inflation | Adult/Pediatric 170 ± 10mmHg (22.7 ± 1.3kPa) | |
Neonate 100 ± 10mmHg (16.0 ± 1.3kPa) | ||
Deflation Pressure | 30mmHg(4.0kPa) higher than the last systolic pressure. | |
Cuff Inflation Rate | No greater than 50mmHg/sec | |
Measurement Time | Typical 25 seconds | |
Maximun 40 seconds | ||
Typical Stat 20 seconds | ||
Pressure Display Accuracy | ± 3mmHg |
► Company Profile
As a medical equipment expert, we have many years of experience in the production and sales of medical equipment. Our products are of high quality and have always won unanimous praise from customers at home and abroad. We are proficient in medical equipment maintenance technology, and have always been at the forefront of developing the most advanced types of medical equipment and accessories to provide customers and society with the best quality services. We adhere to the concept of win-win cooperation and are committed to protecting the medical device market, providing perfect preferential prices, excellent quality, and reliable services.
.
Thank you for your time and interest. If you want to explore more details about Goldway UT4000A UT4000B UT4000C UT4000F patient monitor NIBP board GW4F5S01C, please let us know.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!