China factories

China factory - China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 8713180 Patient Monitor Accessories Infusomat Perfusor Space 4.8v 2.1Ah Battery
China 8713180 Patient Monitor Accessories Infusomat Perfusor Space 4.8v 2.1Ah Battery

  1. China 8713180 Patient Monitor Accessories Infusomat Perfusor Space 4.8v 2.1Ah Battery
  2. China 8713180 Patient Monitor Accessories Infusomat Perfusor Space 4.8v 2.1Ah Battery
  3. China 8713180 Patient Monitor Accessories Infusomat Perfusor Space 4.8v 2.1Ah Battery
  4. China 8713180 Patient Monitor Accessories Infusomat Perfusor Space 4.8v 2.1Ah Battery

8713180 Patient Monitor Accessories Infusomat Perfusor Space 4.8v 2.1Ah Battery

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T(wire transfer), Western Union, Paypal
Delivery Time 3-5 working days
Packaging Details Carton
Product Name 8713180 B.Braun Infusomat Perfusor Space 4.8v 2.1Ah Battery
Brand B. Braun
Manufacturer B. Braun
For Use With For Perfusor® Space PCA Infusion Pump System
Specifications 4.8V, Rechargeable
Voltage / Capacity 4.8 Volt 2.10 Ah
Dimensions 106mm (L) x 30mm (W) x 40mm (H)
Approx. Weight 200g
Chemistry Nickel Metal Hydride (Ni-MH)
Type OEM
Warranty 90 days
MOQ One piece
Brand Name B.Braun
Model Number 8713180
Certification CE
Place of Origin Germany

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T(wire transfer), Western Union, Paypal Delivery Time 3-5 working days
Packaging Details Carton Product Name 8713180 B.Braun Infusomat Perfusor Space 4.8v 2.1Ah Battery
Brand B. Braun Manufacturer B. Braun
For Use With For Perfusor® Space PCA Infusion Pump System Specifications 4.8V, Rechargeable
Voltage / Capacity 4.8 Volt 2.10 Ah Dimensions 106mm (L) x 30mm (W) x 40mm (H)
Approx. Weight 200g Chemistry Nickel Metal Hydride (Ni-MH)
Type OEM Warranty 90 days
MOQ One piece Brand Name B.Braun
Model Number 8713180 Certification CE
Place of Origin Germany
High Light 8713180 Patient Monitor Accessories2.1Ah Battery Pack Patient Monitor AccessoriesPatient Monitor 4.8v Battery Pack

8713180 B.Braun Infusomat Perfusor Space 4.8v 2.1Ah Battery Pack

 

 

 

Battery maintenance: In order to accurately balance the battery capacity, periodic battery maintenance is required. The battery maintenance frequency can be set in the service tool. The battery maintenance mode detects possible capacity loss (for example, due to aging of the battery pack) and will then recalculate the capacity/run time. If there is no battery maintenance after a long storage time or a long operation, it may happen that the battery warning time can no longer be maintained. In this case, battery maintenance is necessary. To start the discharging process, the "Battery Maintenance" message and the key will be displayed after the pump is turned off. Press kandu and the discharge process will start. Interrupt the process by turning on the pump again. If you want to continue battery maintenance, you need to reactivate it. After the battery is fully discharged, it will be fully charged again. The total duration of the battery maintenance process is approximately required. Twelve hours.

Note: Please note that if battery maintenance is not completed, the battery runtime may be shortened. Battery replacement: The battery pack SP can be replaced by any user. No special qualifications are required. All rechargeable batteries will decrease in capacity as they age. This aging depends on several factors, including charging cycles, temperature, and battery usage. It is recommended to check the function of the battery regularly. If replacing the disposable battery causes the "battery almost exhausted" or "battery exhausted" alarm to sound when fully charged, the battery should not be used.

 

Note: If the battery is opened or incinerated, it may explode or leak. Consider the processing direction!

 

 

 

 

Part Number 8713180
Brand B. Braun
Manufacturer B. Braun
For Use With For Perfusor® Space PCA Infusion Pump System
Specifications 4.8V, Rechargeable
Voltage / Capacity 4.8 Volt 2.10 Ah
Dimensions 106mm (L) x 30mm (W) x 40mm (H)
Approx. Weight 200g
Chemistry Nickel Metal Hydride (Ni-MH)
Type OEM

 

 

 

The service life of a new battery at 100 ml/h is 4 hours. In order to optimally dispose of the battery, the device is equipped with protection against overcharging and deep depletion. The battery pack is charged by the pump when it is connected to the power source. When disconnected from the main power supply or power failure, the pump will automatically switch to battery power supply.

 

 

 

 

Note: Before storing the pump for a long time (> 5 months), the battery pack must be fully charged and then removed from the pump. Before replacing the battery, be sure to disconnect the pump from the patient and turn off the device. The battery status indicator is a trend display (low, medium, high). For more detailed information on the current battery capacity (working time in hours and minutes), please refer to the menu item "Batt. Cap." in the status menu of the Infusomat® Space.

 

Caution: The battery operating time displayed on the pump is an approximation based on the current delivery rate. Changes in the delivery rate may affect the operating time of the battery. The one-time replacement program requires high power consumption. An aging battery may suddenly interrupt the battery's working time. In this case, the battery must be replaced with a new one. If you want to take powerful drugs for a long time without the main power supply, it is recommended to have a fully charged backup pump on hand. Note: In the case of ESD, Pump may need to be plugged into a wall outlet to restart the battery. Note: If the battery module is stored outside the pump for a long time, it is recommended to fully charge the battery and store it at room temperature.

Note: If the battery is opened or incinerated, it may explode or leak. Consider the processing direction! Important information for battery self-test: If the battery symbol flashes during mains operation, the remaining battery power is less than 30 minutes. In this case, the pump should not be disconnected from the power supply. If the pump needs to be disconnected from the main power supply for emergency reasons, the user should check to ensure that the battery capacity is sufficient for the recommended use. When the battery symbol flashes permanently (>1h), the battery must be checked by a technician and replaced under the following conditions

 

Optimal battery usage instructions: Actual battery life may vary due to the following reasons

• Ambient temperature

• Changing load (for example, frequent boluses).

 

The best service life of the battery pack can only be achieved when it is completely discharged from time to time. Built-in maintenance mode for this battery maintenance. This feature should be activated once a month. also:

• If you charge an incompletely discharged battery several times, its capacity may decrease.

• Under normal temperature conditions, the battery can be charged and discharged for approximately 2 hours. After 500 times, its life will be shortened.

• When the pump is not connected to mains power, the battery will discharge slowly. This can happen even when the pump is not running.

• Battery runtime can only be achieved when the pump is running

A fully charged battery can be used continuously at room temperature.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2015

  • Employee Number:

    20~50

  • Ecer Certification:

    Verified Supplier

China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...

+ Read More

Get in touch with us

  • Reach Us
  • China World Technology Medical Equipment Service Group
  • TianHe District,GuangZhou,GuangDong
  • https://www.patients-monitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement