Payment Terms | Western Union,T/T |
ProducT Name | GEHC-IT UI LEFT BOARD |
Part Number | 2037646-001 |
Warranty | 90 Days |
Type | Monitor Parts |
MOQ | 1 Piece |
Size | Small |
Weight | Light |
Quality | Good |
Condition | Used-Good |
More Details | Contact us |
Brand Name | GE |
Model Number | DASH1800 |
View Detail Information
Explore similar products
Patient Monitor Accessories Goldway UT4000 Monitor Blood Pressure Plate Great
Mindray PM7000 Patient Monitor Accessories Keyboard Silicone 7000-20-24395
Well-chosen Patient Monitor Mainboard Goldway G30 40 60 70 80 UT4000B UT6000
Patient Monitor Repair Parts GE Dash4000 Patient Monitor Flat Cable in ready
Product Specification
Payment Terms | Western Union,T/T | ProducT Name | GEHC-IT UI LEFT BOARD |
Part Number | 2037646-001 | Warranty | 90 Days |
Type | Monitor Parts | MOQ | 1 Piece |
Size | Small | Weight | Light |
Quality | Good | Condition | Used-Good |
More Details | Contact us | Brand Name | GE |
Model Number | DASH1800 | ||
High Light | Power Switch Patient Monitor Board ,Dash1800 Patient Monitor Board ,GEHC-IT UI Patient Monitor Board |
GE Dash1800 Patient Monitor GEHC-IT UI LEFT BOARD ( Power Switch Board) 2037646-001 2037729-001
■ Product Describe
GE Dash1800 Patient Monitor GEHC-IT UI LEFT BOARD (Power Switch Board) 2037646-001 2037729-001 is the original power switch control board of GE Dash1800 patient monitor and one of the core components of the monitor power supply system.
It has many important functions, mainly for the management of the monitor power on and off control, feedback of power supply status and overcurrent protection of the battery.
The service life of the power switch board is designed to be 5-10 years, and its key components are designed according to this service life; the mechanical life of the relay can reach more than 100,000 on-off operations. If the machine is turned on and off once a day, it can be used for about 270 years (actually affected by the load current, the relay life in medical equipment is usually estimated to be 5-8 years).
■ Product Advantages
1. Modular design
The multi-layer PCB board welded by surface mount technology (SMT) integrates key components such as power management chip (PMIC), relays, fuses, status indicators, etc., and is suitable for embedded installation on the left operation panel of Dash1800.
2. Anti-accidental touch
The external insulation protection cover prevents medical staff from accidentally touching the high-voltage circuit; the buttons are made of medical-grade silicone material, which is resistant to disinfection and corrosion and can withstand more than 100,000 press tests
3. Low-cost maintenance
Modular replacement: No need to disassemble the entire monitor, only 4 cross screws need to be removed to replace the power switch board, and the average maintenance time is ≤15 minutes.
Preventive maintenance: Support online firmware upgrades, and the PMIC control program can be updated through GE engineer-specific tools to optimize power efficiency.
4. Environmental adaptability
Anti-electromagnetic interference: The PCB board is wrapped with a copper foil shielding layer, which can resist ±15kV electrostatic discharge (ESD) and 10V/m radio frequency interference, ensuring stable operation in strong interference environments such as MRI rooms.
Dust and moisture proof: IPX5 protection level, can withstand 30° angle water spray test, and adapt to complex environments such as operating rooms and ICUs.
■ Product Pictures
■ Product Specification
Product Name | Power Switch Board |
Model | Dash1800 |
Input voltage | 100-240V AC(50/60Hz) |
Output voltage | +12V(5A),+5V(3A),+3.3V(2A) |
Conversion efficiency | ≥92% (full load) |
Standby power consumption | ≤0.5W |
Dimensions | 120mm×80mm×25mm(Flush Mount) |
Weight | ≤200g |
AC input interface | IEC 60320 C14 receptacle (compatible with NEMA 5-15P plug) |
DC output interface | 2.54mm pitch pin header (12Pin) |
■ FAQ
Q: How to determine whether the power switch board is faulty?
A: If the monitor screen displays "power module abnormality" or the power indicator light is off, you can use a multimeter to check whether the output voltage is normal.
Q: Can a third-party power switch board be used as a substitute?
A: It is not recommended to use a third-party power switch control board as a substitute. Compatibility is not guaranteed and the lack of medical safety certification may cause equipment failure or data loss.
Q: How long is the warranty period for the power switch board?
A: This is a used original accessory. We give the accessory a 90-day warranty.
If you need any medical equipment and accessories, please contact us.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!