Payment Terms | T/T, Western Union, Paypal |
Delivery Time | 3-5 Working Days |
Packaging Details | Carton |
Brand | Nihon Kohden TEC-5602 Defibrillator |
Color | Green |
Model | UR-0493 6190-909778 |
Warranty | 90 Days |
Packing weight | 1kg |
size | Uniform size |
Application area | ICU,medical equipment opearting room |
Condition | used or new |
Estimated Ship Time | 3-5 Waking Days |
In stock | Enough stock |
Material | circuit board |
Used for | Defibrillator |
net weight | 0.25kg |
Shape | standard |
Brand Name | Nihon Kohden |
Model Number | UR-0493 6190-909778 |
Place of Origin | Japan |
View Detail Information
Explore similar products
REF 4-07-0001 Lithium MnO2 Battery 12V 2,8Ah for defibrillator Fred Easy
Omron AED HDF-3500 bottom case White Color Medical Equipment parts for Hospital
Mainboard E204460 050-002195-07 050-000374-00 For Mindray D3 Defibrillator
Hospital Defibrillator Machine Parts 100-240V Power Supply
Product Specification
Payment Terms | T/T, Western Union, Paypal | Delivery Time | 3-5 Working Days |
Packaging Details | Carton | Brand | Nihon Kohden TEC-5602 Defibrillator |
Color | Green | Model | UR-0493 6190-909778 |
Warranty | 90 Days | Packing weight | 1kg |
size | Uniform size | Application area | ICU,medical equipment opearting room |
Condition | used or new | Estimated Ship Time | 3-5 Waking Days |
In stock | Enough stock | Material | circuit board |
Used for | Defibrillator | net weight | 0.25kg |
Shape | standard | Brand Name | Nihon Kohden |
Model Number | UR-0493 6190-909778 | Place of Origin | Japan |
High Light | 6190-909778 Defibrillator Alarm Indicator Board ,Nihon Kohden Defibrillator Alarm Indicator Board |
Common faults of defibrillators
①Cannot turn on the machine, the AC indicator light is on, and the switch encoder is broken.
②The self-test cannot be passed, the energy cannot be charged to the preset value, and the power PCA is broken.
③If an error is reported, it is mostly due to a bad power PCA.
④It can only work with batteries and cannot use AC power. The power supply of the whole machine is broken
⑤Turn on the machine and enter self-test mode, and the panel is short-circuited.
⑥Display back panel.
⑦There are many broken motherboards.
⑧It reports low battery, but the battery is full. Capacity detection circuit problem.
⑨No sound, no display, the motherboard is broken.
This product is Nihon Kohden TEC-5602 Defibrillator Alarm Indicator Board UR-0493 6190-909778,When determining the main board fault of the defibrillator, please find a professional engineer to inspect and repair it, determine whether it is the main board fault, and find the accurate replacement model of the main board.
As an important component of medical equipment, multi parameter electrocardiogram monitors play a crucial role in the medical process. Over time, multi parameter electrocardiogram monitors may also experience various malfunctions. Common malfunctions include power on system failure, irregular or no electrocardiogram waveform, communication system failure, blood oxygen saturation measurement failure, non-invasive blood pressure measurement failure, and so on.
We medical equipment engineers need to deeply learn and understand the system structure and working principle of electrocardiogram monitors, so that in the future, when encountering faults, we can quickly identify the cause of the fault and repair it, ensure the normal operation of hospital medical equipment, help medical personnel timely grasp the patient's physiological condition, timely raise emergency alarm signals, and provide emergency conditions, which is conducive to improving the efficiency of rescue and effectively reducing the workload of hospital doctors.
Type: | Nihon Kohden TEC-5602 Defibrillator Alarm Indicator Board UR-0493 6190-909778 |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODEL: | UR-0493 6190-909778 |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Green |
Delivery Date: | 3 - 5 Working Days |
Package | Standard export packaging |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex,etc.We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!