China factories

China factory - China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair
China Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair

  1. China Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair
  2. China Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair
  3. China Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair
  4. China Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair
  5. China Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair
  6. China Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair

Used Nihon Kohden CardioLife TEC-5602 Defibrillator For Repair

  1. MOQ: One Piece
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union,Paypal
Delivery Time 3-5 working days
Packaging Details Canton
Product Name Used Nihon Kohden TEC-5602 Defibrillator For Repair
Brand Nihon Kohden
Model NO TEC-5602
Weight 6.8 kg±10% (defibrillator, battery pack, external paddles, external paddle holders)
Dimensions 311(W) × 288(H) × 242(D) mm±10%
Manual mode For charging to a user-specified energy level by using the CHARGE/AED button
Display 6.5-inch diagonal, color TFT-LCD
Display area: 132.48 mm × 99.36 mm
Number of pixels: 640(H) × 480(V) pixels
Power-supply voltage range 100 V to 240 V
Brand Name Nihon Kohden
Model Number TEC-5602

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union,Paypal Delivery Time 3-5 working days
Packaging Details Canton Product Name Used Nihon Kohden TEC-5602 Defibrillator For Repair
Brand Nihon Kohden Model NO TEC-5602
Weight 6.8 kg±10% (defibrillator, battery pack, external paddles, external paddle holders) Dimensions 311(W) × 288(H) × 242(D) mm±10%
Manual mode For charging to a user-specified energy level by using the CHARGE/AED button Display 6.5-inch diagonal, color TFT-LCD
Display area: 132.48 mm × 99.36 mm Number of pixels: 640(H) × 480(V) pixels
Power-supply voltage range 100 V to 240 V Brand Name Nihon Kohden
Model Number TEC-5602
High Light Used Nihon Kohden DefibrillatorCardioLife TEC-5602 DefibrillatorRepair Nihon Kohden Defibrillator

Nihon Kohden TEC-5602 Defibrillator For Repair

 

 

 

 

Features of Nihon Kohden TEC-5602 Defibrillator

 

  • To improve the success rate of defibrillation, the required energy must be transmitted to the patient within 20ms.

Nihon Kohden's unique ACTI biphasic wave technology can control the energy release time within 20ms, even for patients with high transthoracic impedance.

 

  • It can still work normally in harsh environments;

The application of special materials and components allows TEC-5602/TEC-5621/TEC-5631 to work at minus 5 degrees

The IP44 waterproof and dustproof capability ensures the normal use of TEC-5602/TEC-5621/TEC- 5631 in harsh outdoor conditions

 

 

 

 

 

 

Specification Of Nihon Kohden TEC-5602 Defibrillator For Repair

 

 

Manual mode

For charging to a user-specified energy level by using the CHARGE/AED button

 

Manual sync mode:

For charging to a user-specified energy level by using the CHARGE/AED button, then discharging in synchronization with the R-wave of an ECG after the SHOCK button is pressed

 

 

AED mode:

For charging up to the automatically specified energy level when defibrillation is required for the ECG. The energy level varies, depending on the sequence defined in advance

 

External paddles

2, 3, 5, 7, 10, 15, 20, 30, 50, 70, 100, 150, 200, or 270 J selectable

 

Internal paddles:

2, 3, 5, 7, 10, 15, 20, 30, or 50 J selectable

 

Disposal pads:

2, 3, 5, 7, 10, 15, 20, 30, 50, 70, 100, 150, 200, or 270 J selectable

 

Display

6.5-inch diagonal, color TFT-LCD

 

Display area:

132.48 mm × 99.36 mm

 

Number of pixels:

640(H) × 480(V) pixels

 

Recording sensitivity

10 mm/mV±10% or less

 

Frequency response

0.05 to 150 Hz (attenuation 3 dB or less) for a sinusoidal input of 2 mVp-p and 10 Hz as the reference

 

 

Recording paper speed

25 mm/s±10% or less or 50 mm/s±10% or less

 

Power-supply voltage range:

100 V to 240 V

 

Power frequency:

50 Hz or 60 Hz

 

Continuous loading:

150 VA or less

 

Intermittent loading:

300 VA or less

 

Battery Type

Ni-MH battery

 

Capacity:

2800 mAh

 

Weight

6.8 kg±10% (defibrillator, battery pack, external paddles, external paddle holders)

 

Dimensions

311(W) × 288(H) × 242(D) mm±10%

 

 

 

 

Photos of Used Nihon Kohden TEC-5602 Defibrillator For Repair

 

 

Thank you so much for your attention .If you're intererested in Used Nihon Kohden TEC-5602 Defibrillator For Repair ,feel free to contact us .Thank you .

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2015

  • Employee Number:

    20~50

  • Ecer Certification:

    Verified Supplier

China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...

+ Read More

Get in touch with us

  • Reach Us
  • China World Technology Medical Equipment Service Group
  • TianHe District,GuangZhou,GuangDong
  • https://www.patients-monitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement